1,500 kg
Cooling
EN 14511-2
+7°C/+12°C
El input
1.60 kW
Cooling capacity
5.02
EER
3.14
EN 14825
+7°C/+12°C
Pdesignc
5.02 kW
SEER
4.12
Pdc Tj = 35°C
5.02 kW
EER Tj = 35°C
3.14
Pdc Tj = 30°C
3.70 kW
EER Tj = 30°C
4.03
Cdc Tj = 30 °C
1.0
Pdc Tj = 25°C
2.70 kW
EER Tj = 25°C
4.80
Cdc Tj = 25 °C
1.0
Pdc Tj = 20°C
2.96 kW
EER Tj = 20°C
6.10
Cdc Tj = 20 °C
1.0
Poff
19 W
PTO
0 W
PSB
19 W
PCK
30 W
Annual energy consumption Qce
730 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.08 kW
5.74 kW
El input
1.35 kW
2.09 kW
COP
4.51
2.75
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
126 %
Prated
7.00 kW
7.00 kW
SCOP
4.46
3.21
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
6.10 kW
5.80 kW
COP Tj = -7°C
2.96
2.08
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
3.70 kW
3.60 kW
COP Tj = +2°C
4.36
3.30
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.20 kW
3.00 kW
COP Tj = +7°C
5.56
3.49
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.70 kW
3.60 kW
COP Tj = 12°C
7.88
6.49
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
6.10 kW
5.80 kW
COP Tj = Tbiv
2.96
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.10 kW
6.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
1.95
WTOL
60 °C
60 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
30 W
30 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3179 kWh
4191 kWh
Cooling
EN 14511-2
+7°C/+12°C
El input
1.99 kW
Cooling capacity
6.08
EER
3.05
EN 14825
+7°C/+12°C
Pdesignc
6.08 kW
SEER
4.25
Pdc Tj = 35°C
6.08 kW
EER Tj = 35°C
3.05
Pdc Tj = 30°C
4.49 kW
EER Tj = 30°C
4.07
Cdc Tj = 30 °C
1.0
Pdc Tj = 25°C
2.74 kW
EER Tj = 25°C
4.84
Cdc Tj = 25 °C
1.0
Pdc Tj = 20°C
3.02 kW
EER Tj = 20°C
6.34
Cdc Tj = 20 °C
1.0
Poff
19 W
PTO
0 W
PSB
19 W
PCK
19 W
Annual energy consumption Qce
857 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.81 kW
7.19 kW
El input
1.78 kW
2.59 kW
COP
4.38
2.77
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
128 %
Prated
7.00 kW
7.00 kW
SCOP
4.46
3.27
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
6.50 kW
6.30 kW
COP Tj = -7°C
2.95
1.91
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
4.00 kW
3.80 kW
COP Tj = +2°C
4.37
3.33
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.10 kW
3.10 kW
COP Tj = +7°C
5.55
3.90
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.70 kW
3.60 kW
COP Tj = 12°C
7.86
6.30
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
6.50 kW
6.30 kW
COP Tj = Tbiv
2.95
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.50 kW
6.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.95
WTOL
60 °C
60 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
30 W
30 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3413 kWh
4496 kWh