2,900 kg
Brine/Water Heat Pump
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.49 kW
9.10 kW
El input
2.11 kW
3.20 kW
COP
4.98
2.84
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
154 %
Prated
10.75 kW
9.86 kW
SCOP
5.18
4.05
Tbiv
2 °C
2 °C
TOL
-22 °C
-22 °C
Pdh Tj = +2°C
10.75 kW
9.86 kW
COP Tj = +2°C
4.71
2.84
Cdh Tj = +2 °C
Pdh Tj = +7°C
10.93 kW
10.26 kW
COP Tj = +7°C
5.08
3.68
Cdh Tj = +7 °C
Pdh Tj = 12°C
11.15 kW
10.79 kW
COP Tj = 12°C
5.55
4.80
Cdh Tj = +12 °C
Pdh Tj = Tbiv
10.75 kW
9.86 kW
COP Tj = Tbiv
4.71
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.75 kW
9.86 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.71
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2772 kWh
3252 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
202 %
158 %
Prated
10.75 kW
9.86 kW
SCOP
5.25
4.15
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
10.97 kW
10.35 kW
COP Tj = -7°C
5.18
3.87
Cdh Tj = -7 °C
Pdh Tj = +2°C
11.11 kW
10.66 kW
COP Tj = +2°C
5.46
4.52
Cdh Tj = +2 °C
Pdh Tj = +7°C
11.20 kW
10.88 kW
COP Tj = +7°C
5.65
4.99
Cdh Tj = +7 °C
Pdh Tj = 12°C
11.24 kW
11.06 kW
COP Tj = 12°C
5.74
5.36
Cdh Tj = +12 °C
Pdh Tj = Tbiv
10.75 kW
9.86 kW
COP Tj = Tbiv
4.71
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.75 kW
9.86 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.71
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5050 kWh
5859 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
153 %
Prated
10.75 kW
9.86 kW
SCOP
5.15
4.04
Tbiv
-10 °C
-10 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
10.80 kW
9.99 kW
COP Tj = -7°C
4.80
3.12
Cdh Tj = -7 °C
Pdh Tj = +2°C
10.97 kW
10.44 kW
COP Tj = +2°C
5.18
4.06
Cdh Tj = +2 °C
Pdh Tj = +7°C
11.11 kW
10.70 kW
COP Tj = +7°C
5.46
4.62
Cdh Tj = +7 °C
Pdh Tj = 12°C
11.24 kW
10.97 kW
COP Tj = 12°C
5.75
5.18
Cdh Tj = +12 °C
Pdh Tj = Tbiv
10.75 kW
9.86 kW
COP Tj = Tbiv
4.71
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.75 kW
9.86 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.71
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4316 kWh
5046 kWh
Water/Water Heat Pump
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
13.34 kW
12.51 kW
El input
2.19 kW
3.31 kW
COP
6.08
3.78
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
259 %
207 %
Prated
13.34 kW
12.51 kW
SCOP
6.68
5.38
Tbiv
2 °C
2 °C
TOL
-22 °C
-22 °C
Pdh Tj = +2°C
13.34 kW
12.51 kW
COP Tj = +2°C
6.08
3.78
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.56 kW
13.02 kW
COP Tj = +7°C
6.56
4.90
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.84 kW
13.69 kW
COP Tj = 12°C
7.16
6.39
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.34 kW
12.51 kW
COP Tj = Tbiv
6.08
3.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.34 kW
12.51 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2668 kWh
3105 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
262 %
212 %
Prated
13.34 kW
12.51 kW
SCOP
6.75
5.51
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
13.61 kW
13.13 kW
COP Tj = -7°C
6.69
5.15
Cdh Tj = -7 °C
Pdh Tj = +2°C
13.79 kW
13.53 kW
COP Tj = +2°C
7.05
6.02
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.90 kW
13.80 kW
COP Tj = +7°C
7.29
6.64
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.95 kW
14.03 kW
COP Tj = 12°C
7.41
7.13
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.34 kW
12.51 kW
COP Tj = Tbiv
6.08
3.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.34 kW
12.51 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4869 kWh
5595 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
258 %
207 %
Prated
13.34 kW
12.51 kW
SCOP
6.65
5.38
Tbiv
-10 °C
-10 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
13.40 kW
12.67 kW
COP Tj = -7°C
6.20
4.15
Cdh Tj = -7 °C
Pdh Tj = +2°C
13.61 kW
13.25 kW
COP Tj = +2°C
6.69
5.40
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.79 kW
13.58 kW
COP Tj = +7°C
7.05
6.15
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.95 kW
13.92 kW
COP Tj = 12°C
7.41
6.89
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.34 kW
12.51 kW
COP Tj = Tbiv
6.08
3.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.34 kW
12.51 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4145 kWh
4801 kWh