Certificate holders

Subtype

AQUATOP S11

Certificate Holder
ELCO GmbH
Hohenzollernstrasse 31
72379 Hechingen
Germany
Registration number
011-1W0306
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
AQUATOP S11
Driving energy
n/a
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R410A
Mass of Refrigerant

2,900 kg

Certification Date
04.05.2019
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 1

Models

AQUATOP S11
Configure model
Model name
AQUATOP S11
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.49 kW

9.10 kW

El input

2.11 kW

3.20 kW

COP

4.98

2.84

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

154 %

Prated

10.75 kW

9.86 kW

SCOP

5.18

4.05

Tbiv

2 °C

2 °C

TOL

-22 °C

-22 °C

Pdh Tj = +2°C

10.75 kW

9.86 kW

COP Tj = +2°C

4.71

2.84

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

10.93 kW

10.26 kW

COP Tj = +7°C

5.08

3.68

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

11.15 kW

10.79 kW

COP Tj = 12°C

5.55

4.80

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

10.75 kW

9.86 kW

COP Tj = Tbiv

4.71

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.75 kW

9.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.71

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2772 kWh

3252 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

158 %

Prated

10.75 kW

9.86 kW

SCOP

5.25

4.15

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

10.97 kW

10.35 kW

COP Tj = -7°C

5.18

3.87

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

11.11 kW

10.66 kW

COP Tj = +2°C

5.46

4.52

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

11.20 kW

10.88 kW

COP Tj = +7°C

5.65

4.99

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

11.24 kW

11.06 kW

COP Tj = 12°C

5.74

5.36

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

10.75 kW

9.86 kW

COP Tj = Tbiv

4.71

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.75 kW

9.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.71

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5050 kWh

5859 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

153 %

Prated

10.75 kW

9.86 kW

SCOP

5.15

4.04

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

10.80 kW

9.99 kW

COP Tj = -7°C

4.80

3.12

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

10.97 kW

10.44 kW

COP Tj = +2°C

5.18

4.06

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

11.11 kW

10.70 kW

COP Tj = +7°C

5.46

4.62

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

11.24 kW

10.97 kW

COP Tj = 12°C

5.75

5.18

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

10.75 kW

9.86 kW

COP Tj = Tbiv

4.71

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.75 kW

9.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.71

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4316 kWh

5046 kWh

Water/Water Heat Pump

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

13.34 kW

12.51 kW

El input

2.19 kW

3.31 kW

COP

6.08

3.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

207 %

Prated

13.34 kW

12.51 kW

SCOP

6.68

5.38

Tbiv

2 °C

2 °C

TOL

-22 °C

-22 °C

Pdh Tj = +2°C

13.34 kW

12.51 kW

COP Tj = +2°C

6.08

3.78

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

13.56 kW

13.02 kW

COP Tj = +7°C

6.56

4.90

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

13.84 kW

13.69 kW

COP Tj = 12°C

7.16

6.39

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

13.34 kW

12.51 kW

COP Tj = Tbiv

6.08

3.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.34 kW

12.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2668 kWh

3105 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

262 %

212 %

Prated

13.34 kW

12.51 kW

SCOP

6.75

5.51

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

13.61 kW

13.13 kW

COP Tj = -7°C

6.69

5.15

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

13.79 kW

13.53 kW

COP Tj = +2°C

7.05

6.02

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

13.90 kW

13.80 kW

COP Tj = +7°C

7.29

6.64

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

13.95 kW

14.03 kW

COP Tj = 12°C

7.41

7.13

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

13.34 kW

12.51 kW

COP Tj = Tbiv

6.08

3.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.34 kW

12.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4869 kWh

5595 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

258 %

207 %

Prated

13.34 kW

12.51 kW

SCOP

6.65

5.38

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

13.40 kW

12.67 kW

COP Tj = -7°C

6.20

4.15

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

13.61 kW

13.25 kW

COP Tj = +2°C

6.69

5.40

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

13.79 kW

13.58 kW

COP Tj = +7°C

7.05

6.15

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

13.95 kW

13.92 kW

COP Tj = 12°C

7.41

6.89

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

13.34 kW

12.51 kW

COP Tj = Tbiv

6.08

3.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.34 kW

12.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4145 kWh

4801 kWh