Certificate holders

Subtype

AEROTOP T35 / T35R

Certificate Holder
ELCO GmbH
Hohenzollernstrasse 31
72379 Hechingen
Germany
Registration number
011-1W0303
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
AEROTOP T35 / T35R
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R407c
Mass of Refrigerant

9,200 kg

Certification Date
04.05.2019
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

AEROTOP T35
Configure model
Model name
AEROTOP T35
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

39.60 kW

37.20 kW

El input

9.66 kW

12.80 kW

COP

4.10

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

68 dB(A)

68 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

143 %

Prated

30.32 kW

28.00 kW

SCOP

4.45

3.65

Tbiv

2 °C

2 °C

TOL

-20 °C

-10 °C

Pdh Tj = +2°C

30.32 kW

28.20 kW

COP Tj = +2°C

3.46

2.70

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

40.08 kW

38.28 kW

COP Tj = +7°C

4.39

3.36

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

44.45 kW

43.69 kW

COP Tj = 12°C

5.08

4.46

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

30.32 kW

28.20 kW

COP Tj = Tbiv

3.46

2.70

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

30.32 kW

28.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.46

2.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

10017 kWh

14192 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

68 dB(A)

68 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

98 %

Prated

25.85 kW

34.90 kW

SCOP

3.69

2.53

Tbiv

-15 °C

-10 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

26.53 kW

25.32 kW

COP Tj = -7°C

3.32

2.47

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

31.17 kW

30.11 kW

COP Tj = +2°C

4.07

3.31

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

40.80 kW

39.96 kW

COP Tj = +7°C

4.83

4.32

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

44.63 kW

44.26 kW

COP Tj = 12°C

5.23

4.92

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

21.09 kW

23.90 kW

COP Tj = Tbiv

2.67

2.43

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

21.05 kW

23.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

2.43

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

25.85 kW

34.90 kW

Annual energy consumption Qhe

17170 kWh

33619 kWh

Pdh Tj = -15°C (if TOL<-20°C)

0.01

0.01

COP Tj = -15°C (if TOL<-20°C)

0.01

0.01

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

68 dB(A)

68 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

121 %

Prated

24.50 kW

23.40 kW

SCOP

3.90

3.11

Tbiv

-10 °C

-10 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

26.19 kW

24.63 kW

COP Tj = -7°C

3.06

2.12

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

30.85 kW

29.58 kW

COP Tj = +2°C

3.84

2.95

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

40.56 kW

39.48 kW

COP Tj = +7°C

4.69

4.03

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

44.63 kW

44.07 kW

COP Tj = 12°C

5.23

4.77

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

24.50 kW

23.40 kW

COP Tj = Tbiv

2.90

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

24.50 kW

23.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

12964 kWh

15691 kWh

AEROTOP T35R
Configure model
Model name
AEROTOP T35R
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

39.60 kW

37.20 kW

El input

9.66 kW

12.80 kW

COP

4.10

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

68 dB(A)

68 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

143 %

Prated

30.32 kW

28.00 kW

SCOP

4.62

3.65

Tbiv

2 °C

2 °C

TOL

-20 °C

-10 °C

Pdh Tj = +2°C

30.32 kW

28.20 kW

COP Tj = +2°C

3.46

2.70

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

40.08 kW

38.28 kW

COP Tj = +7°C

4.39

3.36

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

44.45 kW

43.69 kW

COP Tj = 12°C

5.08

4.46

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

30.32 kW

28.20 kW

COP Tj = Tbiv

3.46

2.70

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

30.32 kW

28.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.46

2.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

9664 kWh

13839 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

68 dB(A)

68 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

146 %

99 %

Prated

25.85 kW

34.90 kW

SCOP

7.73

2.54

Tbiv

-15 °C

-10 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

26.53 kW

25.32 kW

COP Tj = -7°C

3.32

2.47

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

31.17 kW

30.11 kW

COP Tj = +2°C

4.07

3.31

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

40.80 kW

39.96 kW

COP Tj = +7°C

4.83

4.32

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

44.63 kW

44.26 kW

COP Tj = 12°C

5.23

4.92

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

21.09 kW

23.90 kW

COP Tj = Tbiv

2.67

2.43

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

21.05 kW

23.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

2.43

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

25.85 kW

34.90 kW

Annual energy consumption Qhe

16994 kWh

33442 kWh

Pdh Tj = -15°C (if TOL<-20°C)

0.01

0.01

COP Tj = -15°C (if TOL<-20°C)

0.01

0.01

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

68 dB(A)

68 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

124 %

Prated

24.50 kW

23.40 kW

SCOP

3.99

3.17

Tbiv

-10 °C

-10 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

26.19 kW

24.63 kW

COP Tj = -7°C

3.06

2.12

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

30.85 kW

29.58 kW

COP Tj = +2°C

3.84

2.95

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

40.56 kW

39.48 kW

COP Tj = +7°C

4.69

4.03

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

44.63 kW

44.07 kW

COP Tj = 12°C

5.23

4.77

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

24.50 kW

23.40 kW

COP Tj = Tbiv

2.90

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

24.50 kW

23.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

12670 kWh

15397 kWh