Certificate holders

Subtype

AEROTOP T32 / T32R

Certificate Holder
ELCO GmbH
Hohenzollernstrasse 31
72379 Hechingen
Germany
Registration number
011-1W0302
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
AEROTOP T32 / T32R
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R407c
Mass of Refrigerant

9,200 kg

Certification Date
04.05.2019
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

AEROTOP T32
Configure model
Model name
AEROTOP T32
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

38.00 kW

37.00 kW

El input

8.84 kW

13.70 kW

COP

4.30

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

63 dB(A)

63 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

144 %

Prated

27.39 kW

26.90 kW

SCOP

4.74

3.67

Tbiv

2 °C

2 °C

TOL

-20 °C

-10 °C

Pdh Tj = +2°C

27.39 kW

26.90 kW

COP Tj = +2°C

3.26

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

38.20 kW

37.45 kW

COP Tj = +7°C

4.74

3.26

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

43.41 kW

42.51 kW

COP Tj = 12°C

5.67

4.74

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

27.39 kW

26.90 kW

COP Tj = Tbiv

3.26

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

27.39 kW

26.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.26

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6876 kWh

9801 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

63 dB(A)

63 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

139 %

94 %

Prated

23.66 kW

31.70 kW

SCOP

3.54

2.44

Tbiv

-15 °C

-10 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

24.83 kW

23.63 kW

COP Tj = -7°C

3.08

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

27.59 kW

27.34 kW

COP Tj = +2°C

3.95

3.09

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

38.50 kW

38.15 kW

COP Tj = +7°C

5.39

4.63

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

43.63 kW

43.18 kW

COP Tj = 12°C

5.90

5.44

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

19.30 kW

21.68 kW

COP Tj = Tbiv

2.25

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

19.30 kW

21.68 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.22

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

23.66 kW

31.70 kW

Annual energy consumption Qhe

16470 kWh

34596 kWh

Pdh Tj = -15°C (if TOL<-20°C)

0.01

0.01

COP Tj = -15°C (if TOL<-20°C)

0.01

0.01

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

63 dB(A)

63 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

114 %

Prated

22.50 kW

21.00 kW

SCOP

3.89

2.93

Tbiv

-10 °C

-10 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

24.49 kW

22.95 kW

COP Tj = -7°C

2.86

2.01

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

27.51 kW

27.22 kW

COP Tj = +2°C

3.69

2.69

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

38.40 kW

37.95 kW

COP Tj = +7°C

5.17

4.19

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

43.63 kW

42.96 kW

COP Tj = 12°C

5.90

5.20

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

43.41 kW

21.00 kW

COP Tj = Tbiv

2.60

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

22.50 kW

21.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

11960 kWh

16478 kWh

AEROTOP T32R
Configure model
Model name
AEROTOP T32R
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

38.00 kW

37.00 kW

El input

8.84 kW

13.70 kW

COP

4.30

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

63 dB(A)

63 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

144 %

Prated

27.39 kW

26.90 kW

SCOP

5.00

3.67

Tbiv

2 °C

2 °C

TOL

-20 °C

-10 °C

Pdh Tj = +2°C

27.39 kW

26.90 kW

COP Tj = +2°C

3.26

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

38.20 kW

37.45 kW

COP Tj = +7°C

4.74

3.26

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

43.41 kW

42.51 kW

COP Tj = 12°C

5.67

4.74

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

27.39 kW

26.90 kW

COP Tj = Tbiv

3.26

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

27.39 kW

26.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.26

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6523 kWh

9801 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

63 dB(A)

63 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

140 %

95 %

Prated

23.66 kW

31.70 kW

SCOP

3.58

2.45

Tbiv

-15 °C

-10 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

24.83 kW

23.63 kW

COP Tj = -7°C

3.08

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

27.59 kW

27.34 kW

COP Tj = +2°C

3.95

3.09

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

38.50 kW

38.15 kW

COP Tj = +7°C

5.39

4.63

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

43.63 kW

43.18 kW

COP Tj = 12°C

5.90

5.44

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

19.30 kW

21.68 kW

COP Tj = Tbiv

2.25

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

19.30 kW

21.68 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.22

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

23.66 kW

31.70 kW

Annual energy consumption Qhe

16294 kWh

34419 kWh

Pdh Tj = -15°C (if TOL<-20°C)

0.01

0.01

COP Tj = -15°C (if TOL<-20°C)

0.01

0.01

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

63 dB(A)

63 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

116 %

Prated

22.50 kW

21.00 kW

SCOP

3.98

2.99

Tbiv

-10 °C

-10 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

24.49 kW

22.95 kW

COP Tj = -7°C

2.86

2.01

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

27.51 kW

27.22 kW

COP Tj = +2°C

3.69

2.69

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

38.40 kW

37.95 kW

COP Tj = +7°C

5.17

4.19

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

43.63 kW

42.96 kW

COP Tj = 12°C

5.90

5.20

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

43.41 kW

21.00 kW

COP Tj = Tbiv

2.60

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

22.50 kW

21.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

11666 kWh

16185 kWh