Certificate holders

Subtype

AEROTOP T20 / T20R

Certificate Holder
ELCO GmbH
Hohenzollernstrasse 31
72379 Hechingen
Germany
Registration number
011-1W0300
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
AEROTOP T20 / T20R
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R407c
Mass of Refrigerant

6,000 kg

Certification Date
04.05.2019
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

AEROTOP T20
Configure model
Model name
AEROTOP T20
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

22.40 kW

19.95 kW

El input

5.90 kW

7.50 kW

COP

3.80

2.66

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

59 dB(A)

59 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

108 %

Prated

16.78 kW

14.00 kW

SCOP

3.97

2.77

Tbiv

2 °C

2 °C

TOL

-10 °C

-10 °C

Pdh Tj = +2°C

16.78 kW

14.00 kW

COP Tj = +2°C

3.10

1.89

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

22.89 kW

21.05 kW

COP Tj = +7°C

4.07

3.11

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

25.29 kW

24.75 kW

COP Tj = 12°C

4.60

2.17

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

16.78 kW

14.00 kW

COP Tj = Tbiv

3.10

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.78 kW

14.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6362 kWh

9220 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

59 dB(A)

59 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

127 %

91 %

Prated

14.83 kW

18.80 kW

SCOP

3.25

2.34

Tbiv

-15 °C

-10 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

15.08 kW

13.63 kW

COP Tj = -7°C

2.80

2.25

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

17.89 kW

16.50 kW

COP Tj = +2°C

3.70

2.95

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

23.63 kW

22.77 kW

COP Tj = +7°C

4.48

4.01

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

25.43 kW

25.16 kW

COP Tj = 12°C

4.74

4.47

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

12.10 kW

12.86 kW

COP Tj = Tbiv

2.37

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.05 kW

12.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.34

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

14.83 kW

18.80 kW

Annual energy consumption Qhe

11167 kWh

20867 kWh

Pdh Tj = -15°C (if TOL<-20°C)

0.01

0.01

COP Tj = -15°C (if TOL<-20°C)

0.01

0.01

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

59 dB(A)

59 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

139 %

107 %

Prated

14.00 kW

12.00 kW

SCOP

3.56

2.75

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.66 kW

12.81 kW

COP Tj = -7°C

2.64

1.99

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

17.48 kW

15.81 kW

COP Tj = +2°C

3.48

2.59

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

23.38 kW

22.28 kW

COP Tj = +7°C

4.35

3.73

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

25.43 kW

25.02 kW

COP Tj = 12°C

4.74

4.33

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

25.29 kW

12.00 kW

COP Tj = Tbiv

2.50

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.90 kW

12.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

8071 kWh

10203 kWh

AEROTOP T20R
Configure model
Model name
AEROTOP T20R
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

22.40 kW

19.95 kW

El input

5.90 kW

7.50 kW

COP

3.80

2.66

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

59 dB(A)

59 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

112 %

Prated

16.78 kW

14.00 kW

SCOP

4.20

2.88

Tbiv

2 °C

2 °C

TOL

-20 °C

-10 °C

Pdh Tj = +2°C

16.78 kW

14.00 kW

COP Tj = +2°C

3.10

1.89

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

22.89 kW

21.05 kW

COP Tj = +7°C

4.07

3.11

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

25.29 kW

24.75 kW

COP Tj = 12°C

4.60

2.17

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

16.78 kW

14.00 kW

COP Tj = Tbiv

3.10

4.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.78 kW

14.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6009 kWh

8867 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

59 dB(A)

59 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

129 %

91 %

Prated

14.83 kW

18.80 kW

SCOP

3.30

2.36

Tbiv

-15 °C

-10 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

15.08 kW

13.63 kW

COP Tj = -7°C

2.80

2.25

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

17.89 kW

16.50 kW

COP Tj = +2°C

3.70

2.95

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

23.63 kW

22.77 kW

COP Tj = +7°C

4.48

4.01

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

25.43 kW

25.16 kW

COP Tj = 12°C

4.48

4.47

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

12.10 kW

12.86 kW

COP Tj = Tbiv

2.37

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.05 kW

12.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.34

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

14.83 kW

18.80 kW

Annual energy consumption Qhe

10990 kWh

20690 kWh

Pdh Tj = -15°C (if TOL<-20°C)

0.01

0.01

COP Tj = -15°C (if TOL<-20°C)

0.01

0.01

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

59 dB(A)

59 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

110 %

Prated

13.90 kW

12.00 kW

SCOP

3.69

2.84

Tbiv

-10 °C

-10 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

14.66 kW

12.81 kW

COP Tj = -7°C

2.64

1.99

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

17.48 kW

15.81 kW

COP Tj = +2°C

3.48

2.59

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

23.38 kW

22.28 kW

COP Tj = +7°C

4.35

3.73

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

25.43 kW

25.02 kW

COP Tj = 12°C

4.74

4.33

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

13.90 kW

12.00 kW

COP Tj = Tbiv

2.50

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.90 kW

12.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

57 °C

57 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

7777 kWh

9910 kWh