Certificate holders

Subtype

AEROTOP SG14 INOX / INOX OPTIC

Certificate Holder
ELCO GmbH
Hohenzollernstrasse 31
72379 Hechingen
Germany
Registration number
011-1W0476
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
AEROTOP SG14 INOX / INOX OPTIC
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

4,270 kg

Certification Date
05.07.2021
Testing basis
HP KEYMARK certification scheme rules rev. 8
Generate PDF Export model CSV
  • Number of models 1

Models

AEROTOP SG14 INOX / INOX OPTIC
Configure model
Model name
AEROTOP SG14 INOX / INOX OPTIC
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.15 kW

13.30 kW

El input

1.78 kW

6.43 kW

COP

5.13

2.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

165 %

Prated

10.10 kW

9.75 kW

SCOP

5.68

4.19

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.10 kW

9.75 kW

COP Tj = +2°C

4.19

2.88

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

6.60 kW

6.35 kW

COP Tj = +7°C

5.69

3.87

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

4.48 kW

4.30 kW

COP Tj = 12°C

7.47

5.66

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

10.10 kW

9.75 kW

COP Tj = Tbiv

4.19

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

9.75 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.19

2.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

24 W

24 W

PSB

24 W

24 W

PCK

24 W

24 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2375 kWh

3109 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

150 %

127 %

Prated

23.13 kW

22.63 kW

SCOP

3.83

3.26

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

14.00 kW

13.70 kW

COP Tj = -7°C

3.21

2.74

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

8.52 kW

8.37 kW

COP Tj = +2°C

5.67

4.45

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.50 kW

5.40 kW

COP Tj = +7°C

6.59

5.57

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

4.37 kW

4.47 kW

COP Tj = 12°C

8.50

7.10

Cdh Tj = +12 °C

0.960

0.980

Pdh Tj = Tbiv

14.00 kW

13.70 kW

COP Tj = Tbiv

3.21

2.74

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.52 kW

9.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.22

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.960

0.960

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

24 W

24 W

PSB

24 W

24 W

PCK

24 W

24 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

23.13 kW

22.63 kW

Annual energy consumption Qhe

14890 kWh

17120 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

151 %

Prated

15.70 kW

15.15 kW

SCOP

4.64

3.85

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

13.89 kW

13.40 kW

COP Tj = -7°C

2.93

2.38

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

8.84 kW

8.51 kW

COP Tj = +2°C

4.69

3.80

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.58 kW

5.53 kW

COP Tj = +7°C

6.27

5.42

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

4.43 kW

4.40 kW

COP Tj = 12°C

7.70

6.57

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

13.89 kW

13.40 kW

COP Tj = Tbiv

2.93

2.38

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.79 kW

12.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.74

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.960

0.960

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

24 W

24 W

PSB

24 W

24 W

PCK

24 W

24 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.91 kW

2.64 kW

Annual energy consumption Qhe

6993 kWh

8129 kWh