4,270 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.15 kW
6.70 kW
El input
1.32 kW
2.12 kW
COP
5.40
3.16
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
220 %
154 %
Prated
8.24 kW
7.70 kW
SCOP
5.57
3.93
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.24 kW
7.70 kW
COP Tj = +2°C
4.56
2.95
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
5.18 kW
COP Tj = +7°C
5.70
3.58
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
4.48 kW
4.30 kW
COP Tj = 12°C
7.47
5.54
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
8.24 kW
7.70 kW
COP Tj = Tbiv
4.56
2.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.24 kW
7.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.56
2.95
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
24 W
24 W
PTO
24 W
24 W
PSB
24 W
24 W
PCK
24 W
24 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1977 kWh
2616 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
128 %
Prated
18.64 kW
18.44 kW
SCOP
3.86
3.26
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
11.28 kW
11.16 kW
COP Tj = -7°C
3.63
3.04
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
6.82 kW
6.86 kW
COP Tj = +2°C
5.68
4.40
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.38 kW
4.38 kW
COP Tj = +7°C
6.35
5.54
Cdh Tj = +7 °C
0.960
0.960
Pdh Tj = 12°C
4.37 kW
4.47 kW
COP Tj = 12°C
8.25
7.10
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
11.28 kW
11.16 kW
COP Tj = Tbiv
3.63
3.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.93 kW
6.08 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.03
1.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.960
0.960
WTOL
60 °C
60 °C
Poff
24 W
24 W
PTO
24 W
24 W
PSB
24 W
24 W
PCK
24 W
24 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
18.64 kW
18.44 kW
Annual energy consumption Qhe
11889 kWh
13937 kWh
Pdh Tj = -15°C (if TOL<-20°C)
COP Tj = -15°C (if TOL<-20°C)
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
206 %
150 %
Prated
12.63 kW
12.58 kW
SCOP
5.23
3.83
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.17 kW
11.15 kW
COP Tj = -7°C
3.87
2.64
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
6.85 kW
6.76 kW
COP Tj = +2°C
5.27
3.95
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.37 kW
4.36 kW
COP Tj = +7°C
6.75
4.62
Cdh Tj = +7 °C
0.960
0.960
Pdh Tj = 12°C
4.34 kW
4.20 kW
COP Tj = 12°C
8.26
6.35
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
11.17 kW
11.15 kW
COP Tj = Tbiv
3.87
2.64
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
10.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
2.27
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.960
0.960
WTOL
60 °C
60 °C
Poff
24 W
24 W
PTO
24 W
24 W
PSB
24 W
24 W
PCK
24 W
24 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.63 kW
1.78 kW
Annual energy consumption Qhe
4984 kWh
6793 kWh