Certificate holders

Subtype

AEROTOP SG10 INOX / INOX OPTIC

Certificate Holder
ELCO GmbH
Hohenzollernstrasse 31
72379 Hechingen
Germany
Registration number
011-1W0472
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
AEROTOP SG10 INOX / INOX OPTIC
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

4,270 kg

Certification Date
05.07.2021
Testing basis
HP KEYMARK certification scheme rules rev. 8
Generate PDF Export model CSV
  • Number of models 1

Models

AEROTOP SG10 INOX / INOX OPTIC
Configure model
Model name
AEROTOP SG10 INOX / INOX OPTIC
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.10 kW

4.85 kW

El input

0.95 kW

1.50 kW

COP

5.35

3.24

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

201 %

159 %

Prated

5.35 kW

4.98 kW

SCOP

5.11

4.03

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.35 kW

4.98 kW

COP Tj = +2°C

4.29

2.60

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.81 kW

3.77 kW

COP Tj = +7°C

5.65

4.52

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

4.45 kW

4.25 kW

COP Tj = 12°C

7.47

5.65

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

5.35 kW

4.98 kW

COP Tj = Tbiv

4.29

2.60

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.35 kW

4.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

24 W

25 W

PSB

24 W

24 W

PCK

24 W

24 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1400 kWh

1649 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

154 %

125 %

Prated

13.42 kW

13.55 kW

SCOP

3.92

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.12 kW

8.20 kW

COP Tj = -7°C

3.63

2.91

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.85 kW

4.93 kW

COP Tj = +2°C

5.67

4.30

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

3.95 kW

3.80 kW

COP Tj = +7°C

7.10

5.47

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

4.47 kW

4.25 kW

COP Tj = 12°C

8.25

7.10

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

8.12 kW

8.20 kW

COP Tj = Tbiv

3.63

2.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.41 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.00

1.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.960

0.960

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

24 W

25 W

PSB

24 W

24 W

PCK

24 W

24 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

13.42 kW

13.55 kW

Annual energy consumption Qhe

8434 kWh

10423 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

141 %

Prated

9.21 kW

9.20 kW

SCOP

4.91

3.59

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.15 kW

8.03 kW

COP Tj = -7°C

3.46

2.39

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

5.08 kW

4.95 kW

COP Tj = +2°C

5.12

3.60

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

3.72 kW

3.65 kW

COP Tj = +7°C

6.21

4.82

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

4.34 kW

4.28 kW

COP Tj = 12°C

8.25

6.64

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

8.15 kW

8.03 kW

COP Tj = Tbiv

3.46

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.10 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.960

0.960

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

24 W

25 W

PSB

24 W

24 W

PCK

24 W

24 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.11 kW

0.20 kW

Annual energy consumption Qhe

3879 kWh

5299 kWh