Certificate holders

Subtype

AEROTOP S09.2

Certificate Holder
ELCO GmbH
Hohenzollernstrasse 31
72379 Hechingen
Germany
Registration number
011-1W0392
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
AEROTOP S09.2
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

4,000 kg

Certification Date
28.07.2020
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

AEROTOP S09.2
Configure model
Model name
AEROTOP S09.2
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.75 kW

7.25 kW

El input

1.34 kW

3.23 kW

COP

5.05

2.24

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

230 %

172 %

Prated

9.05 kW

9.78 kW

SCOP

5.81

4.38

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

9.05 kW

9.78 kW

COP Tj = +2°C

3.79

2.68

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

6.75 kW

6.34 kW

COP Tj = +7°C

5.04

3.89

Cdh Tj = +7 °C

0.94

0.94

Pdh Tj = 12°C

3.01 kW

2.94 kW

COP Tj = 12°C

7.34

5.35

Cdh Tj = +12 °C

0.93

0.93

Pdh Tj = Tbiv

9.05 kW

9.78 kW

COP Tj = Tbiv

3.79

2.68

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.05 kW

9.78 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.79

2.68

WTOL

63 °C

63 °C

Poff

35 W

35 W

PTO

36 W

36 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2081 kWh

2983 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

151 %

117 %

Prated

11.28 kW

10.57 kW

SCOP

3.84

3.01

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

6.83 kW

6.40 kW

COP Tj = -7°C

3.12

2.44

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.25 kW

3.79 kW

COP Tj = +2°C

5.38

4.21

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.62 kW

2.58 kW

COP Tj = +7°C

6.24

4.96

Cdh Tj = +7 °C

0.940

0.940

Pdh Tj = 12°C

3.03 kW

3.03 kW

COP Tj = 12°C

7.77

6.45

Cdh Tj = +12 °C

0.930

0.930

Pdh Tj = Tbiv

6.83 kW

6.40 kW

COP Tj = Tbiv

3.12

2.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.91 kW

6.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.02

1.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

63 °C

63 °C

Poff

35 W

35 W

PTO

36 W

36 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

11.28 kW

10.57 kW

Annual energy consumption Qhe

7241 kWh

8667 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

134 %

Prated

9.91 kW

8.20 kW

SCOP

4.99

3.42

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.77 kW

7.25 kW

COP Tj = -7°C

3.18

2.24

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

5.59 kW

4.60 kW

COP Tj = +2°C

4.99

3.13

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

3.58 kW

3.07 kW

COP Tj = +7°C

6.28

4.95

Cdh Tj = +7 °C

0.94

0.94

Pdh Tj = 12°C

3.03 kW

3.00 kW

COP Tj = 12°C

7.77

6.00

Cdh Tj = +12 °C

0.93

0.93

Pdh Tj = Tbiv

8.77 kW

7.25 kW

COP Tj = Tbiv

3.18

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.47 kW

9.03 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.80

WTOL

63 °C

63 °C

Poff

35 W

35 W

PTO

36 W

36 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.44 kW

0.00 kW

Annual energy consumption Qhe

4108 kWh

4948 kWh

AEROTOP S09.2_2-parts
Configure model
Model name
AEROTOP S09.2_2-parts
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.75 kW

7.25 kW

El input

1.34 kW

3.23 kW

COP

5.05

2.24

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

230 %

172 %

Prated

9.05 kW

9.78 kW

SCOP

5.81

4.38

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

9.05 kW

9.78 kW

COP Tj = +2°C

3.79

2.68

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

6.75 kW

6.34 kW

COP Tj = +7°C

5.04

3.89

Cdh Tj = +7 °C

0.94

0.94

Pdh Tj = 12°C

3.01 kW

2.94 kW

COP Tj = 12°C

7.34

5.35

Cdh Tj = +12 °C

0.93

0.93

Pdh Tj = Tbiv

9.05 kW

9.78 kW

COP Tj = Tbiv

3.79

2.68

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.05 kW

9.78 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.79

2.68

WTOL

63 °C

63 °C

Poff

35 W

35 W

PTO

36 W

36 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2081 kWh

2983 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

151 %

117 %

Prated

11.28 kW

10.57 kW

SCOP

3.84

3.01

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

6.83 kW

6.40 kW

COP Tj = -7°C

3.12

2.44

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.25 kW

3.79 kW

COP Tj = +2°C

5.38

4.21

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.62 kW

2.58 kW

COP Tj = +7°C

6.24

4.96

Cdh Tj = +7 °C

0.940

0.940

Pdh Tj = 12°C

3.03 kW

3.03 kW

COP Tj = 12°C

7.77

6.45

Cdh Tj = +12 °C

0.930

0.930

Pdh Tj = Tbiv

6.83 kW

6.40 kW

COP Tj = Tbiv

3.12

2.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.91 kW

6.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.02

1.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

63 °C

63 °C

Poff

35 W

35 W

PTO

36 W

36 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

11.28 kW

10.57 kW

Annual energy consumption Qhe

7241 kWh

8667 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

134 %

Prated

9.91 kW

8.20 kW

SCOP

4.99

3.42

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.77 kW

7.25 kW

COP Tj = -7°C

3.18

2.24

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

5.59 kW

4.60 kW

COP Tj = +2°C

4.99

3.13

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

3.58 kW

3.07 kW

COP Tj = +7°C

6.28

4.95

Cdh Tj = +7 °C

0.94

0.94

Pdh Tj = 12°C

3.03 kW

3.00 kW

COP Tj = 12°C

7.77

6.00

Cdh Tj = +12 °C

0.93

0.93

Pdh Tj = Tbiv

8.77 kW

7.25 kW

COP Tj = Tbiv

3.18

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.47 kW

9.03 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.80

WTOL

63 °C

63 °C

Poff

35 W

35 W

PTO

36 W

36 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.44 kW

0.00 kW

Annual energy consumption Qhe

4108 kWh

4948 kWh