Certificate holders

Subtype

WPF 07, WPF 07 cool, WPC 07, WPC 07 cool

Certificate Holder
STIEBEL ELTRON GmbH & Co KG
Dr. Stiebel Straße 33
37603 Holzminden
Germany
Registration number
011-1W0020
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
WPF 07, WPF 07 cool, WPC 07, WPC 07 cool
Driving energy
n/a
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

1,720 kg

Certification Date
23.08.2016
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 8

Models

WPF 07, all climates
Configure model
Model name
WPF 07, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

7.50 kW

El input

1.55 kW

COP

4.84

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Warmer Climate

EN 12102-1

Sound power level indoor

50 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

204 %

Prated

8.00 kW

SCOP

5.31

Tbiv

2 °C

TOL

0 °C

Pdh Tj = -7°C

0.00 kW

COP Tj = -7°C

0.00

Pdh Tj = +2°C

7.50 kW

COP Tj = +2°C

4.84

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

7.60 kW

COP Tj = +7°C

5.17

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

7.70 kW

COP Tj = 12°C

5.73

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

7.50 kW

COP Tj = Tbiv

4.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.84

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.50 kW

Annual energy consumption Qhe

1888 kWh

Colder Climate

EN 12102-1

Sound power level indoor

50 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

211 %

Prated

9.00 kW

SCOP

5.48

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

7.60 kW

COP Tj = -7°C

5.42

Cdh Tj = -7 °C

 

Pdh Tj = +2°C

7.70 kW

COP Tj = +2°C

5.70

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

7.70 kW

COP Tj = +7°C

5.93

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

7.70 kW

COP Tj = 12°C

5.97

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

7.60 kW

COP Tj = Tbiv

5.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.31

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.40 kW

Annual energy consumption Qhe

4184 kWh

Average Climate

EN 12102-1

Sound power level indoor

50 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

205 %

Prated

8.00 kW

SCOP

5.32

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

7.50 kW

COP Tj = -7°C

4.90

Pdh Tj = +2°C

7.60 kW

COP Tj = +2°C

5.25

Pdh Tj = +7°C

7.60 kW

COP Tj = +7°C

5.60

Pdh Tj = 12°C

7.70 kW

COP Tj = 12°C

5.99

Pdh Tj = Tbiv

7.50 kW

COP Tj = Tbiv

4.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.84

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

2912 kWh

WPF 07 cool, all climates
Configure model
Model name
WPF 07 cool, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

7.50 kW

El input

1.55 kW

COP

4.84

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Warmer Climate

EN 12102-1

Sound power level indoor

50 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

204 %

Prated

8.00 kW

SCOP

5.31

Tbiv

2 °C

TOL

0 °C

Pdh Tj = -7°C

0.00 kW

COP Tj = -7°C

0.00

Pdh Tj = +2°C

7.50 kW

COP Tj = +2°C

4.84

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

7.60 kW

COP Tj = +7°C

5.17

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

7.70 kW

COP Tj = 12°C

5.73

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

7.50 kW

COP Tj = Tbiv

4.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.84

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.50 kW

Annual energy consumption Qhe

1888 kWh

Colder Climate

EN 12102-1

Sound power level indoor

50 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

211 %

Prated

9.00 kW

SCOP

5.48

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

7.60 kW

COP Tj = -7°C

5.42

Cdh Tj = -7 °C

 

Pdh Tj = +2°C

7.70 kW

COP Tj = +2°C

5.70

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

7.70 kW

COP Tj = +7°C

5.93

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

7.70 kW

COP Tj = 12°C

5.97

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

7.60 kW

COP Tj = Tbiv

5.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.31

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.40 kW

Annual energy consumption Qhe

4184 kWh

Average Climate

EN 12102-1

Sound power level indoor

50 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

205 %

Prated

8.00 kW

SCOP

5.32

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

7.50 kW

COP Tj = -7°C

4.90

Pdh Tj = +2°C

7.60 kW

COP Tj = +2°C

5.25

Pdh Tj = +7°C

7.60 kW

COP Tj = +7°C

5.60

Pdh Tj = 12°C

7.70 kW

COP Tj = 12°C

5.99

Pdh Tj = Tbiv

7.50 kW

COP Tj = Tbiv

4.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.84

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

2912 kWh

WPC 07, all climates
Configure model
Model name
WPC 07, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

7.50 kW

El input

1.55 kW

COP

4.84

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Warmer Climate

EN 12102-1

Sound power level indoor

52 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

204 %

Prated

8.00 kW

SCOP

5.31

Tbiv

2 °C

TOL

0 °C

Pdh Tj = -7°C

0.00 kW

COP Tj = -7°C

0.00

Pdh Tj = +2°C

7.50 kW

COP Tj = +2°C

4.84

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

7.60 kW

COP Tj = +7°C

5.17

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

7.70 kW

COP Tj = 12°C

5.73

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

7.50 kW

COP Tj = Tbiv

4.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.84

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.50 kW

Annual energy consumption Qhe

1888 kWh

Colder Climate

EN 12102-1

Sound power level indoor

52 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

211 %

Prated

9.00 kW

SCOP

5.48

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

7.60 kW

COP Tj = -7°C

5.42

Cdh Tj = -7 °C

 

Pdh Tj = +2°C

7.70 kW

COP Tj = +2°C

5.70

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

7.70 kW

COP Tj = +7°C

5.93

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

7.70 kW

COP Tj = 12°C

5.97

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

7.60 kW

COP Tj = Tbiv

5.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.31

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.40 kW

Annual energy consumption Qhe

4184 kWh

Average Climate

EN 12102-1

Sound power level indoor

52 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

205 %

Prated

8.00 kW

SCOP

5.32

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

7.50 kW

COP Tj = -7°C

4.90

Pdh Tj = +2°C

7.60 kW

COP Tj = +2°C

5.25

Pdh Tj = +7°C

7.60 kW

COP Tj = +7°C

5.60

Pdh Tj = 12°C

7.70 kW

COP Tj = 12°C

5.99

Pdh Tj = Tbiv

7.50 kW

COP Tj = Tbiv

4.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.84

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

2912 kWh

WPC 07 cool, all climates
Configure model
Model name
WPC 07 cool, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

7.50 kW

El input

1.55 kW

COP

4.84

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Warmer Climate

EN 12102-1

Sound power level indoor

52 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

204 %

Prated

8.00 kW

SCOP

5.31

Tbiv

2 °C

TOL

0 °C

Pdh Tj = -7°C

0.00 kW

COP Tj = -7°C

0.00

Pdh Tj = +2°C

7.50 kW

COP Tj = +2°C

4.84

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

7.60 kW

COP Tj = +7°C

5.17

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

7.70 kW

COP Tj = 12°C

5.73

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

7.50 kW

COP Tj = Tbiv

4.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.84

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.50 kW

Annual energy consumption Qhe

1888 kWh

Colder Climate

EN 12102-1

Sound power level indoor

52 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

211 %

Prated

9.00 kW

SCOP

5.48

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

7.60 kW

COP Tj = -7°C

5.42

Cdh Tj = -7 °C

 

Pdh Tj = +2°C

7.70 kW

COP Tj = +2°C

5.70

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

7.70 kW

COP Tj = +7°C

5.93

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

7.70 kW

COP Tj = 12°C

5.97

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

7.60 kW

COP Tj = Tbiv

5.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.31

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.40 kW

Annual energy consumption Qhe

4184 kWh

Average Climate

EN 12102-1

Sound power level indoor

52 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

205 %

Prated

8.00 kW

SCOP

5.32

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

7.50 kW

COP Tj = -7°C

4.90

Pdh Tj = +2°C

7.60 kW

COP Tj = +2°C

5.25

Pdh Tj = +7°C

7.60 kW

COP Tj = +7°C

5.60

Pdh Tj = 12°C

7.70 kW

COP Tj = 12°C

5.99

Pdh Tj = Tbiv

7.50 kW

COP Tj = Tbiv

4.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.84

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

2912 kWh

WPF 07, average climates
Configure model
Model name
WPF 07, average climates
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

6.91 kW

El input

1.55 kW

2.35 kW

COP

4.84

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

0 dB(A)

0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

139 %

Prated

8.00 kW

7.00 kW

SCOP

5.32

3.67

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.50 kW

7.00 kW

COP Tj = -7°C

4.90

3.07

Pdh Tj = +2°C

7.60 kW

7.20 kW

COP Tj = +2°C

5.25

3.61

Pdh Tj = +7°C

7.60 kW

7.30 kW

COP Tj = +7°C

5.60

4.02

Pdh Tj = 12°C

7.70 kW

7.40 kW

COP Tj = 12°C

5.99

4.52

Pdh Tj = Tbiv

7.50 kW

6.90 kW

COP Tj = Tbiv

4.84

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.50 kW

6.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.84

2.94

Rated airflow rate

0 m³/h

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

54 W

54 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2912 kWh

3891 kWh

WPF 07 cool, average climates
Configure model
Model name
WPF 07 cool, average climates
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

6.91 kW

El input

1.55 kW

2.35 kW

COP

4.84

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

0 dB(A)

0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

139 %

Prated

8.00 kW

7.00 kW

SCOP

5.32

3.67

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.50 kW

7.00 kW

COP Tj = -7°C

4.90

3.07

Pdh Tj = +2°C

7.60 kW

7.20 kW

COP Tj = +2°C

5.25

3.61

Pdh Tj = +7°C

7.60 kW

7.30 kW

COP Tj = +7°C

5.60

4.02

Pdh Tj = 12°C

7.70 kW

7.40 kW

COP Tj = 12°C

5.99

4.52

Pdh Tj = Tbiv

7.50 kW

6.90 kW

COP Tj = Tbiv

4.84

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.50 kW

6.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.84

2.94

Rated airflow rate

0 m³/h

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

54 W

54 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2912 kWh

3891 kWh

WPC 07 , average climates
Configure model
Model name
WPC 07 , average climates
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

6.91 kW

El input

1.55 kW

2.35 kW

COP

4.84

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

52 dB(A)

52 dB(A)

Sound power level outdoor

0 dB(A)

0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

139 %

Prated

8.00 kW

7.00 kW

SCOP

5.32

3.67

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.50 kW

7.00 kW

COP Tj = -7°C

4.90

3.07

Pdh Tj = +2°C

7.60 kW

7.20 kW

COP Tj = +2°C

5.25

3.61

Pdh Tj = +7°C

7.60 kW

7.30 kW

COP Tj = +7°C

5.60

4.02

Pdh Tj = 12°C

7.70 kW

7.40 kW

COP Tj = 12°C

5.99

4.52

Pdh Tj = Tbiv

7.50 kW

6.90 kW

COP Tj = Tbiv

4.84

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.50 kW

6.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.84

2.94

Rated airflow rate

0 m³/h

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

54 W

54 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2912 kWh

3891 kWh

WPC 07 cool, average climates
Configure model
Model name
WPC 07 cool, average climates
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

6.91 kW

El input

1.55 kW

2.35 kW

COP

4.84

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

52 dB(A)

52 dB(A)

Sound power level outdoor

0 dB(A)

0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

139 %

Prated

8.00 kW

7.00 kW

SCOP

5.32

3.67

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.50 kW

7.00 kW

COP Tj = -7°C

4.90

3.07

Pdh Tj = +2°C

7.60 kW

7.20 kW

COP Tj = +2°C

5.25

3.61

Pdh Tj = +7°C

7.60 kW

7.30 kW

COP Tj = +7°C

5.60

4.02

Pdh Tj = 12°C

7.70 kW

7.40 kW

COP Tj = 12°C

5.99

4.52

Pdh Tj = Tbiv

7.50 kW

6.90 kW

COP Tj = Tbiv

4.84

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.50 kW

6.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.84

2.94

Rated airflow rate

0 m³/h

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

54 W

54 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2912 kWh

3891 kWh