1,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.17 kW
5.66 kW
El input
1.25 kW
1.98 kW
COP
4.94
2.87
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.11 kW
1.59 kW
Cooling capacity
3.71
6.87
EER
3.33
4.31
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.71 kW
6.90 kW
SEER
3.99
5.65
Pdc Tj = 35°C
3.71 kW
6.90 kW
EER Tj = 35°C
3.33
4.31
Pdc Tj = 30°C
2.82 kW
5.16 kW
EER Tj = 30°C
3.93
6.68
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
2.12 kW
3.29 kW
EER Tj = 25°C
4.14
6.17
Cdc Tj = 25 °C
0.981
0.250
Pdc Tj = 20°C
2.42 kW
3.09 kW
EER Tj = 20°C
5.31
6.65
Cdc Tj = 20 °C
0.978
0.979
Poff
9 W
9 W
PTO
10 W
10 W
PSB
16 W
16 W
PCK
0 W
0 W
Annual energy consumption Qce
887 kWh
1164 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
206 %
159 %
Prated
4.54 kW
4.15 kW
SCOP
5.21
4.05
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.54 kW
4.15 kW
COP Tj = +2°C
3.71
2.18
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.13 kW
3.77 kW
COP Tj = +7°C
6.04
3.39
Cdh Tj = +7 °C
0.900
0.991
Pdh Tj = 12°C
3.48 kW
4.19 kW
COP Tj = 12°C
5.06
5.51
Cdh Tj = +12 °C
0.986
0.987
Pdh Tj = Tbiv
4.54 kW
4.15 kW
COP Tj = Tbiv
3.71
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.54 kW
4.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.71
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
10 W
10 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1164 kWh
1366 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
120 %
Prated
4.01 kW
3.24 kW
SCOP
4.68
3.08
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.73 kW
2.85 kW
COP Tj = -7°C
2.99
1.72
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.64 kW
3.27 kW
COP Tj = +2°C
4.90
3.08
Cdh Tj = +2 °C
0.982
0.991
Pdh Tj = +7°C
3.11 kW
3.63 kW
COP Tj = +7°C
6.08
4.22
Cdh Tj = +7 °C
0.981
0.986
Pdh Tj = 12°C
3.51 kW
3.51 kW
COP Tj = 12°C
5.15
5.71
Cdh Tj = +12 °C
0.985
0.984
Pdh Tj = Tbiv
4.01 kW
3.24 kW
COP Tj = Tbiv
2.63
1.60
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.01 kW
3.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
10 W
10 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1770 kWh
2176 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.17 kW
5.66 kW
El input
1.25 kW
1.98 kW
COP
4.94
2.87
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.11 kW
1.59 kW
Cooling capacity
3.71
6.87
EER
3.33
4.31
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.71 kW
6.90 kW
SEER
3.99
5.65
Pdc Tj = 35°C
3.71 kW
6.90 kW
EER Tj = 35°C
3.33
4.31
Pdc Tj = 30°C
2.82 kW
5.16 kW
EER Tj = 30°C
3.93
6.68
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
2.12 kW
3.29 kW
EER Tj = 25°C
4.14
6.17
Cdc Tj = 25 °C
0.981
0.250
Pdc Tj = 20°C
2.42 kW
3.09 kW
EER Tj = 20°C
5.31
6.65
Cdc Tj = 20 °C
0.978
0.979
Poff
9 W
9 W
PTO
10 W
10 W
PSB
16 W
16 W
PCK
0 W
0 W
Annual energy consumption Qce
887 kWh
1164 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
206 %
159 %
Prated
4.54 kW
4.15 kW
SCOP
5.21
4.05
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.54 kW
4.15 kW
COP Tj = +2°C
3.71
2.18
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.13 kW
3.77 kW
COP Tj = +7°C
6.04
3.39
Cdh Tj = +7 °C
0.900
0.991
Pdh Tj = 12°C
3.48 kW
4.19 kW
COP Tj = 12°C
5.06
5.51
Cdh Tj = +12 °C
0.986
0.987
Pdh Tj = Tbiv
4.54 kW
4.15 kW
COP Tj = Tbiv
3.71
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.54 kW
4.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.71
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
10 W
10 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1164 kWh
1366 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
157 %
101 %
Prated
3.85 kW
3.20 kW
SCOP
4.00
2.59
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-18 °C
Pdh Tj = -7°C
2.35 kW
2.93 kW
COP Tj = -7°C
3.58
2.15
Cdh Tj = -7 °C
0.900
0.993
Pdh Tj = +2°C
2.64 kW
2.99 kW
COP Tj = +2°C
4.89
3.34
Cdh Tj = +2 °C
0.982
0.989
Pdh Tj = +7°C
3.13 kW
2.85 kW
COP Tj = +7°C
6.15
4.38
Cdh Tj = +7 °C
0.981
0.985
Pdh Tj = 12°C
3.48 kW
3.45 kW
COP Tj = 12°C
5.10
4.99
Cdh Tj = +12 °C
0.985
0.986
Pdh Tj = Tbiv
3.14 kW
2.61 kW
COP Tj = Tbiv
2.30
1.37
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.86 kW
2.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.92
1.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
10 W
10 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.99 kW
3.20 kW
Annual energy consumption Qhe
2376 kWh
3042 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.14
2.61
COP Tj = -15°C (if TOL<-20°C)
2.30
1.37
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
127 %
Prated
5.01 kW
4.41 kW
SCOP
4.59
3.24
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.44 kW
3.91 kW
COP Tj = -7°C
2.92
1.92
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.66 kW
2.93 kW
COP Tj = +2°C
4.98
3.17
Cdh Tj = +2 °C
0.900
0.989
Pdh Tj = +7°C
3.06 kW
3.74 kW
COP Tj = +7°C
5.53
4.43
Cdh Tj = +7 °C
0.982
0.988
Pdh Tj = 12°C
3.49 kW
3.60 kW
COP Tj = 12°C
5.15
6.25
Cdh Tj = +12 °C
0.985
0.983
Pdh Tj = Tbiv
4.44 kW
3.91 kW
COP Tj = Tbiv
2.92
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.01 kW
3.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
10 W
10 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.00 kW
1.17 kW
Annual energy consumption Qhe
2257 kWh
2812 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.66 kW
6.88 kW
El input
1.59 kW
2.39 kW
COP
4.81
2.88
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.00 kW
1.46 kW
Cooling capacity
5.71
6.42
EER
2.85
4.41
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.72 kW
6.43 kW
SEER
3.54
5.39
Pdc Tj = 35°C
5.72 kW
6.43 kW
EER Tj = 35°C
2.86
4.42
Pdc Tj = 30°C
4.21 kW
4.66 kW
EER Tj = 30°C
4.27
6.54
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
2.61 kW
3.48 kW
EER Tj = 25°C
4.06
7.20
Cdc Tj = 25 °C
0.250
0.965
Pdc Tj = 20°C
2.36 kW
3.30 kW
EER Tj = 20°C
5.19
7.10
Cdc Tj = 20 °C
0.963
0.963
Poff
7 W
7 W
PTO
17 W
17 W
PSB
12 W
12 W
PCK
0 W
0 W
Annual energy consumption Qce
1542 kWh
1138 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
141 %
Prated
5.48 kW
4.80 kW
SCOP
4.86
3.59
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.48 kW
4.80 kW
COP Tj = +2°C
3.73
2.20
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.55 kW
3.78 kW
COP Tj = +7°C
4.88
3.47
Cdh Tj = +7 °C
0.900
0.984
Pdh Tj = 12°C
3.30 kW
3.20 kW
COP Tj = 12°C
5.26
4.15
Cdh Tj = +12 °C
0.973
0.978
Pdh Tj = Tbiv
5.48 kW
4.80 kW
COP Tj = Tbiv
3.73
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.48 kW
4.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.73
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
17 W
17 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1508 kWh
1788 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
168 %
118 %
Prated
5.14 kW
3.64 kW
SCOP
4.26
3.02
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.26 kW
2.95 kW
COP Tj = -7°C
3.02
1.75
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.99 kW
3.20 kW
COP Tj = +2°C
4.38
3.05
Cdh Tj = +2 °C
0.900
0.984
Pdh Tj = +7°C
2.91 kW
3.59 kW
COP Tj = +7°C
5.02
4.22
Cdh Tj = +7 °C
0.971
0.980
Pdh Tj = 12°C
3.35 kW
3.31 kW
COP Tj = 12°C
5.42
4.83
Cdh Tj = +12 °C
0.973
0.975
Pdh Tj = Tbiv
5.14 kW
3.64 kW
COP Tj = Tbiv
2.59
1.59
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.14 kW
3.64 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
17 W
17 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2493 kWh
2485 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.66 kW
6.88 kW
El input
1.59 kW
2.39 kW
COP
4.81
2.88
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.00 kW
1.46 kW
Cooling capacity
5.71
6.42
EER
2.85
4.41
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.72 kW
6.43 kW
SEER
3.54
5.39
Pdc Tj = 35°C
5.72 kW
6.43 kW
EER Tj = 35°C
2.86
4.42
Pdc Tj = 30°C
4.21 kW
4.66 kW
EER Tj = 30°C
4.27
6.54
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
2.61 kW
3.48 kW
EER Tj = 25°C
4.06
7.20
Cdc Tj = 25 °C
0.250
0.965
Pdc Tj = 20°C
2.36 kW
3.30 kW
EER Tj = 20°C
5.19
7.10
Cdc Tj = 20 °C
0.963
0.963
Poff
7 W
7 W
PTO
17 W
17 W
PSB
12 W
12 W
PCK
0 W
0 W
Annual energy consumption Qce
1542 kWh
1138 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
141 %
Prated
5.48 kW
4.80 kW
SCOP
4.86
3.59
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.48 kW
4.80 kW
COP Tj = +2°C
3.73
2.20
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.55 kW
3.78 kW
COP Tj = +7°C
4.88
3.47
Cdh Tj = +7 °C
0.900
0.984
Pdh Tj = 12°C
3.30 kW
3.20 kW
COP Tj = 12°C
5.26
4.15
Cdh Tj = +12 °C
0.973
0.978
Pdh Tj = Tbiv
5.48 kW
4.80 kW
COP Tj = Tbiv
3.73
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.48 kW
4.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.73
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
17 W
17 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1508 kWh
1788 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
109 %
Prated
5.08 kW
4.96 kW
SCOP
3.99
2.80
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-18 °C
Pdh Tj = -7°C
3.03 kW
3.22 kW
COP Tj = -7°C
3.63
2.37
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.59 kW
2.35 kW
COP Tj = +2°C
4.91
3.56
Cdh Tj = +2 °C
0.968
0.974
Pdh Tj = +7°C
2.95 kW
2.80 kW
COP Tj = +7°C
5.18
4.01
Cdh Tj = +7 °C
0.970
0.976
Pdh Tj = 12°C
3.31 kW
3.23 kW
COP Tj = 12°C
5.30
4.20
Cdh Tj = +12 °C
0.973
0.978
Pdh Tj = Tbiv
4.15 kW
4.05 kW
COP Tj = Tbiv
2.54
1.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.15 kW
3.01 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.88
1.36
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
17 W
17 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.93 kW
4.96 kW
Annual energy consumption Qhe
3142 kWh
4369 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.15
4.05
COP Tj = -15°C (if TOL<-20°C)
2.54
1.75
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
129 %
Prated
6.32 kW
5.62 kW
SCOP
4.26
3.30
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.59 kW
4.97 kW
COP Tj = -7°C
2.83
1.98
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.64 kW
2.97 kW
COP Tj = +2°C
4.42
3.32
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.96 kW
2.82 kW
COP Tj = +7°C
5.19
4.35
Cdh Tj = +7 °C
0.970
0.974
Pdh Tj = 12°C
3.30 kW
3.39 kW
COP Tj = 12°C
5.35
5.41
Cdh Tj = +12 °C
0.972
0.973
Pdh Tj = Tbiv
5.59 kW
4.97 kW
COP Tj = Tbiv
2.83
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.14 kW
3.64 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
17 W
17 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.18 kW
1.97 kW
Annual energy consumption Qhe
3067 kWh
3517 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.17 kW
5.66 kW
El input
1.25 kW
1.98 kW
COP
4.94
2.87
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.11 kW
1.59 kW
Cooling capacity
3.71
6.87
EER
3.33
4.31
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.71 kW
6.90 kW
SEER
3.99
5.65
Pdc Tj = 35°C
3.71 kW
6.90 kW
EER Tj = 35°C
3.33
4.31
Pdc Tj = 30°C
2.82 kW
5.16 kW
EER Tj = 30°C
3.93
6.68
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
2.12 kW
3.29 kW
EER Tj = 25°C
4.14
6.17
Cdc Tj = 25 °C
0.981
0.250
Pdc Tj = 20°C
2.42 kW
3.09 kW
EER Tj = 20°C
5.31
6.65
Cdc Tj = 20 °C
0.978
0.979
Poff
9 W
9 W
PTO
10 W
10 W
PSB
16 W
16 W
PCK
0 W
0 W
Annual energy consumption Qce
887 kWh
1164 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
206 %
159 %
Prated
4.54 kW
4.15 kW
SCOP
5.21
4.05
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.54 kW
4.15 kW
COP Tj = +2°C
3.71
2.18
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.13 kW
3.77 kW
COP Tj = +7°C
6.04
3.39
Cdh Tj = +7 °C
0.900
0.991
Pdh Tj = 12°C
3.48 kW
4.19 kW
COP Tj = 12°C
5.06
5.51
Cdh Tj = +12 °C
0.986
0.987
Pdh Tj = Tbiv
4.54 kW
4.15 kW
COP Tj = Tbiv
3.71
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.54 kW
4.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.71
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
10 W
10 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1164 kWh
1366 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
157 %
101 %
Prated
3.85 kW
3.20 kW
SCOP
4.00
2.59
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-18 °C
Pdh Tj = -7°C
2.35 kW
2.93 kW
COP Tj = -7°C
3.58
2.15
Cdh Tj = -7 °C
0.900
0.993
Pdh Tj = +2°C
2.64 kW
2.99 kW
COP Tj = +2°C
4.89
3.34
Cdh Tj = +2 °C
0.982
0.989
Pdh Tj = +7°C
3.13 kW
2.85 kW
COP Tj = +7°C
6.15
4.38
Cdh Tj = +7 °C
0.981
0.985
Pdh Tj = 12°C
3.48 kW
3.45 kW
COP Tj = 12°C
5.10
4.99
Cdh Tj = +12 °C
0.985
0.986
Pdh Tj = Tbiv
3.14 kW
2.61 kW
COP Tj = Tbiv
2.30
1.37
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.86 kW
2.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.92
1.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
10 W
10 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.99 kW
3.20 kW
Annual energy consumption Qhe
2376 kWh
3042 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.14
2.61
COP Tj = -15°C (if TOL<-20°C)
2.30
1.37
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
127 %
Prated
5.01 kW
4.41 kW
SCOP
4.59
3.24
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.44 kW
3.91 kW
COP Tj = -7°C
2.92
1.92
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.66 kW
2.93 kW
COP Tj = +2°C
4.98
3.17
Cdh Tj = +2 °C
0.900
0.989
Pdh Tj = +7°C
3.06 kW
3.74 kW
COP Tj = +7°C
5.53
4.43
Cdh Tj = +7 °C
0.982
0.988
Pdh Tj = 12°C
3.49 kW
3.60 kW
COP Tj = 12°C
5.15
6.25
Cdh Tj = +12 °C
0.985
0.983
Pdh Tj = Tbiv
4.44 kW
3.91 kW
COP Tj = Tbiv
2.92
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.01 kW
3.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
10 W
10 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.00 kW
1.17 kW
Annual energy consumption Qhe
2257 kWh
2812 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
134 %
COP
3.18
Heating up time
2:27 h:min
Standby power input
36.4 W
Reference hot water temperature
50.3 °C
Mixed water at 40°C
223 l
Colder Climate
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
110 %
COP
2.63
Heating up time
2:49 h:min
Standby power input
35.1 W
Reference hot water temperature
50.2 °C
Mixed water at 40°C
220 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.66 kW
6.88 kW
El input
1.59 kW
2.39 kW
COP
4.81
2.88
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.00 kW
1.46 kW
Cooling capacity
5.71
6.42
EER
2.85
4.41
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.72 kW
6.43 kW
SEER
3.54
5.39
Pdc Tj = 35°C
5.72 kW
6.43 kW
EER Tj = 35°C
2.86
4.42
Pdc Tj = 30°C
4.21 kW
4.66 kW
EER Tj = 30°C
4.27
6.54
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
2.61 kW
3.48 kW
EER Tj = 25°C
4.06
7.20
Cdc Tj = 25 °C
0.250
0.965
Pdc Tj = 20°C
2.36 kW
3.30 kW
EER Tj = 20°C
5.19
7.10
Cdc Tj = 20 °C
0.963
0.963
Poff
7 W
7 W
PTO
17 W
17 W
PSB
12 W
12 W
PCK
0 W
0 W
Annual energy consumption Qce
1542 kWh
1138 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
141 %
Prated
5.48 kW
4.80 kW
SCOP
4.86
3.59
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.48 kW
4.80 kW
COP Tj = +2°C
3.73
2.20
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.55 kW
3.78 kW
COP Tj = +7°C
4.88
3.47
Cdh Tj = +7 °C
0.900
0.984
Pdh Tj = 12°C
3.30 kW
3.20 kW
COP Tj = 12°C
5.26
4.15
Cdh Tj = +12 °C
0.973
0.978
Pdh Tj = Tbiv
5.48 kW
4.80 kW
COP Tj = Tbiv
3.73
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.48 kW
4.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.73
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
17 W
17 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1508 kWh
1788 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
109 %
Prated
5.08 kW
4.96 kW
SCOP
3.99
2.80
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-18 °C
Pdh Tj = -7°C
3.03 kW
3.22 kW
COP Tj = -7°C
3.63
2.37
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.59 kW
2.35 kW
COP Tj = +2°C
4.91
3.56
Cdh Tj = +2 °C
0.968
0.974
Pdh Tj = +7°C
2.95 kW
2.80 kW
COP Tj = +7°C
5.18
4.01
Cdh Tj = +7 °C
0.970
0.976
Pdh Tj = 12°C
3.31 kW
3.23 kW
COP Tj = 12°C
5.30
4.20
Cdh Tj = +12 °C
0.973
0.978
Pdh Tj = Tbiv
4.15 kW
4.05 kW
COP Tj = Tbiv
2.54
1.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.15 kW
3.01 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.88
1.36
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
17 W
17 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.93 kW
4.96 kW
Annual energy consumption Qhe
3142 kWh
4369 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.15
4.05
COP Tj = -15°C (if TOL<-20°C)
2.54
1.75
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
30 dB(A)
30 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
129 %
Prated
6.32 kW
5.62 kW
SCOP
4.26
3.30
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.59 kW
4.97 kW
COP Tj = -7°C
2.83
1.98
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.64 kW
2.97 kW
COP Tj = +2°C
4.42
3.32
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.96 kW
2.82 kW
COP Tj = +7°C
5.19
4.35
Cdh Tj = +7 °C
0.970
0.974
Pdh Tj = 12°C
3.30 kW
3.39 kW
COP Tj = 12°C
5.35
5.41
Cdh Tj = +12 °C
0.972
0.973
Pdh Tj = Tbiv
5.59 kW
4.97 kW
COP Tj = Tbiv
2.83
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.14 kW
3.64 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
17 W
17 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.18 kW
1.97 kW
Annual energy consumption Qhe
3067 kWh
3517 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
157 %
COP
3.76
Heating up time
2:12 h:min
Standby power input
36.5 W
Reference hot water temperature
51.2 °C
Mixed water at 40°C
225 l
Colder Climate
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.82
Heating up time
2:21 h:min
Standby power input
41.0 W
Reference hot water temperature
51.0 °C
Mixed water at 40°C
225 l