Certificate holders

Subtype

FHA-Monoblock 11-17kW

Certificate Holder
WOLF GmbH
Industriestr. 1
84048 Mainburg
Germany
Registration number
011-1W0558
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
FHA-Monoblock 11-17kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,750 kg

Certification Date
17.10.2022
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 10 (as of 2022-06)
Generate PDF Export model CSV
  • Number of models 12

Models

FHA-11/14-230V-M2 FS-C2
Configure model
Model name
FHA-11/14-230V-M2 FS-C2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.30 kW

13.56 kW

El input

3.09 kW

4.86 kW

COP

3.98

2.79

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.25 kW

3.17 kW

Cooling capacity

8.46

10.23

EER

1.99

3.23

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.45 kW

10.23 kW

SEER

4.41

5.65

Pdc Tj = 35°C

8.46 kW

10.23 kW

EER Tj = 35°C

1.99

3.23

Pdc Tj = 30°C

6.68 kW

8.16 kW

EER Tj = 30°C

3.71

5.34

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.10 kW

6.68 kW

EER Tj = 25°C

5.15

6.90

Cdc Tj = 25 °C

0.991

0.991

Pdc Tj = 20°C

4.98 kW

6.22 kW

EER Tj = 20°C

5.10

6.23

Cdc Tj = 20 °C

0.991

0.991

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

1829 kWh

1726 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

247 %

157 %

Prated

9.53 kW

8.41 kW

SCOP

6.24

4.00

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.53 kW

8.41 kW

COP Tj = +2°C

2.99

1.87

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.94 kW

6.95 kW

COP Tj = +7°C

5.75

3.37

Cdh Tj = +7 °C

0.993

0.996

Pdh Tj = 12°C

7.84 kW

7.18 kW

COP Tj = 12°C

7.68

5.36

Cdh Tj = +12 °C

0.991

0.993

Pdh Tj = Tbiv

9.53 kW

8.41 kW

COP Tj = Tbiv

2.99

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.53 kW

8.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.99

1.87

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2039 kWh

2811 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

174 %

122 %

Prated

8.66 kW

8.01 kW

SCOP

4.42

3.12

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.63 kW

6.52 kW

COP Tj = -7°C

2.76

1.65

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.58 kW

5.13 kW

COP Tj = +2°C

4.15

3.12

Cdh Tj = +2 °C

0.993

0.995

Pdh Tj = +7°C

7.11 kW

6.36 kW

COP Tj = +7°C

6.18

4.16

Cdh Tj = +7 °C

0.992

0.994

Pdh Tj = 12°C

7.78 kW

7.44 kW

COP Tj = 12°C

7.72

6.00

Cdh Tj = +12 °C

0.991

0.993

Pdh Tj = Tbiv

8.66 kW

8.01 kW

COP Tj = Tbiv

2.29

1.63

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.66 kW

8.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.29

1.63

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4053 kWh

5312 kWh

FHA-11/14-230V-M2 FS-e6-C2
Configure model
Model name
FHA-11/14-230V-M2 FS-e6-C2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.30 kW

13.56 kW

El input

3.09 kW

4.86 kW

COP

3.98

2.79

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.25 kW

3.17 kW

Cooling capacity

8.46

10.23

EER

1.99

3.23

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.45 kW

10.23 kW

SEER

4.41

5.65

Pdc Tj = 35°C

8.46 kW

10.23 kW

EER Tj = 35°C

1.99

3.23

Pdc Tj = 30°C

6.68 kW

8.16 kW

EER Tj = 30°C

3.71

5.34

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.10 kW

6.68 kW

EER Tj = 25°C

5.15

6.90

Cdc Tj = 25 °C

0.991

0.991

Pdc Tj = 20°C

4.98 kW

6.22 kW

EER Tj = 20°C

5.10

6.23

Cdc Tj = 20 °C

0.991

0.991

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

1829 kWh

1726 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

247 %

157 %

Prated

9.53 kW

8.41 kW

SCOP

6.24

4.00

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.53 kW

8.41 kW

COP Tj = +2°C

2.99

1.87

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.94 kW

6.95 kW

COP Tj = +7°C

5.75

3.37

Cdh Tj = +7 °C

0.993

0.996

Pdh Tj = 12°C

7.84 kW

7.18 kW

COP Tj = 12°C

7.68

5.36

Cdh Tj = +12 °C

0.991

0.993

Pdh Tj = Tbiv

9.53 kW

8.41 kW

COP Tj = Tbiv

2.99

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.53 kW

8.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.99

1.87

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2039 kWh

2811 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

147 %

101 %

Prated

8.88 kW

8.44 kW

SCOP

3.76

2.60

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

5.45 kW

5.23 kW

COP Tj = -7°C

3.42

2.01

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.73 kW

5.23 kW

COP Tj = +2°C

4.34

3.40

Cdh Tj = +2 °C

0.993

0.994

Pdh Tj = +7°C

7.36 kW

6.54 kW

COP Tj = +7°C

6.66

4.61

Cdh Tj = +7 °C

0.992

0.994

Pdh Tj = 12°C

7.74 kW

7.79 kW

COP Tj = 12°C

7.63

6.60

Cdh Tj = +12 °C

0.991

0.992

Pdh Tj = Tbiv

7.25 kW

6.88 kW

COP Tj = Tbiv

2.02

1.53

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.61 kW

6.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.53

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.27 kW

8.44 kW

Annual energy consumption Qhe

5822 kWh

8014 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.25

6.88

COP Tj = -15°C (if TOL<-20°C)

2.02

1.53

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

174 %

126 %

Prated

11.25 kW

9.15 kW

SCOP

4.43

3.22

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.95 kW

8.10 kW

COP Tj = -7°C

2.61

1.74

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.13 kW

5.18 kW

COP Tj = +2°C

4.25

3.24

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.17 kW

6.38 kW

COP Tj = +7°C

6.34

4.22

Cdh Tj = +7 °C

0.992

0.994

Pdh Tj = 12°C

7.76 kW

7.51 kW

COP Tj = 12°C

7.81

6.08

Cdh Tj = +12 °C

0.991

0.993

Pdh Tj = Tbiv

9.95 kW

8.10 kW

COP Tj = Tbiv

2.61

1.74

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.66 kW

8.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.29

1.63

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.59 kW

1.14 kW

Annual energy consumption Qhe

5250 kWh

5880 kWh

FHA-14/17-230V-M2 FS-C2
Configure model
Model name
FHA-14/17-230V-M2 FS-C2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.98 kW

14.78 kW

El input

4.07 kW

5.11 kW

COP

4.17

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.12 kW

4.90 kW

Cooling capacity

10.38

15.52

EER

2.52

3.17

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.38 kW

15.52 kW

SEER

4.48

5.92

Pdc Tj = 35°C

10.38 kW

15.52 kW

EER Tj = 35°C

2.52

3.17

Pdc Tj = 30°C

7.82 kW

10.98 kW

EER Tj = 30°C

3.73

5.15

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

4.89 kW

7.14 kW

EER Tj = 25°C

4.71

7.61

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

4.90 kW

6.37 kW

EER Tj = 20°C

5.15

6.54

Cdc Tj = 20 °C

0.990

0.990

Poff

7 W

7 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Annual energy consumption Qce

2210 kWh

2501 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

261 %

164 %

Prated

12.26 kW

10.23 kW

SCOP

6.60

4.17

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.26 kW

10.23 kW

COP Tj = +2°C

3.20

2.04

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.20 kW

6.88 kW

COP Tj = +7°C

6.00

3.53

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.99 kW

7.17 kW

COP Tj = 12°C

8.17

5.52

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

12.26 kW

10.23 kW

COP Tj = Tbiv

3.20

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.20

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2479 kWh

3277 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

122 %

Prated

9.89 kW

6.68 kW

SCOP

4.82

3.12

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.38 kW

8.94 kW

COP Tj = -7°C

2.83

2.00

Cdh Tj = -7 °C

0.900

0.998

Pdh Tj = +2°C

5.76 kW

4.94 kW

COP Tj = +2°C

4.81

2.99

Cdh Tj = +2 °C

0.900

0.994

Pdh Tj = +7°C

7.00 kW

6.21 kW

COP Tj = +7°C

6.19

4.08

Cdh Tj = +7 °C

0.991

0.994

Pdh Tj = 12°C

7.99 kW

7.29 kW

COP Tj = 12°C

8.33

5.92

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

9.89 kW

6.68 kW

COP Tj = Tbiv

2.41

1.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.89 kW

6.68 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4243 kWh

4430 kWh

FHA-14/17-230V-M2 FS-e6-C2
Configure model
Model name
FHA-14/17-230V-M2 FS-e6-C2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.98 kW

14.78 kW

El input

4.07 kW

5.11 kW

COP

4.17

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.12 kW

4.90 kW

Cooling capacity

10.38

15.52

EER

2.52

3.17

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.38 kW

15.52 kW

SEER

4.48

5.92

Pdc Tj = 35°C

10.38 kW

15.52 kW

EER Tj = 35°C

2.52

3.17

Pdc Tj = 30°C

7.82 kW

10.98 kW

EER Tj = 30°C

3.73

5.15

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

4.89 kW

7.14 kW

EER Tj = 25°C

4.71

7.61

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

4.90 kW

6.37 kW

EER Tj = 20°C

5.15

6.54

Cdc Tj = 20 °C

0.990

0.990

Poff

7 W

7 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Annual energy consumption Qce

2210 kWh

2501 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

261 %

164 %

Prated

12.26 kW

10.23 kW

SCOP

6.60

4.17

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.26 kW

10.23 kW

COP Tj = +2°C

3.20

2.04

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.20 kW

6.88 kW

COP Tj = +7°C

6.00

3.53

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.99 kW

7.17 kW

COP Tj = 12°C

8.17

5.52

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

12.26 kW

10.23 kW

COP Tj = Tbiv

3.20

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.20

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2479 kWh

3277 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

108 %

Prated

9.78 kW

10.62 kW

SCOP

3.96

2.78

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

5.81 kW

6.13 kW

COP Tj = -7°C

3.41

2.28

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.75 kW

5.20 kW

COP Tj = +2°C

4.92

3.52

Cdh Tj = +2 °C

0.992

0.993

Pdh Tj = +7°C

7.07 kW

6.47 kW

COP Tj = +7°C

6.49

4.71

Cdh Tj = +7 °C

0.991

0.993

Pdh Tj = 12°C

8.01 kW

7.43 kW

COP Tj = 12°C

8.30

6.41

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

7.98 kW

8.67 kW

COP Tj = Tbiv

2.14

1.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.65 kW

8.67 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.53

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.13 kW

10.62 kW

Annual energy consumption Qhe

6081 kWh

9423 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.98

8.67

COP Tj = -15°C (if TOL<-20°C)

2.14

1.79

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

131 %

Prated

13.04 kW

12.09 kW

SCOP

4.52

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.53 kW

10.69 kW

COP Tj = -7°C

2.56

2.05

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.99 kW

6.92 kW

COP Tj = +2°C

4.40

3.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.04 kW

6.37 kW

COP Tj = +7°C

6.38

4.43

Cdh Tj = +7 °C

0.991

0.993

Pdh Tj = 12°C

7.99 kW

7.34 kW

COP Tj = 12°C

8.40

6.08

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

11.53 kW

10.69 kW

COP Tj = Tbiv

2.56

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.89 kW

6.68 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.14 kW

5.41 kW

Annual energy consumption Qhe

5959 kWh

7443 kWh

FHA-11/14-400V-M2 FS-C2
Configure model
Model name
FHA-11/14-400V-M2 FS-C2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.65 kW

14.40 kW

El input

3.32 kW

4.93 kW

COP

4.41

2.92

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.65 kW

4.86 kW

Cooling capacity

11.09

15.44

EER

2.39

3.18

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

11.09 kW

15.44 kW

SEER

4.45

5.56

Pdc Tj = 35°C

11.09 kW

15.44 kW

EER Tj = 35°C

2.39

3.18

Pdc Tj = 30°C

8.42 kW

11.59 kW

EER Tj = 30°C

3.68

4.92

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.62 kW

7.70 kW

EER Tj = 25°C

5.04

7.05

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

5.13 kW

6.50 kW

EER Tj = 20°C

5.17

6.42

Cdc Tj = 20 °C

0.983

0.983

Poff

14 W

14 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Annual energy consumption Qce

2378 kWh

2649 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

166 %

Prated

10.76 kW

9.50 kW

SCOP

5.74

4.22

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.76 kW

9.50 kW

COP Tj = +2°C

3.26

2.01

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.96 kW

7.40 kW

COP Tj = +7°C

5.51

3.63

Cdh Tj = +7 °C

0.900

0.992

Pdh Tj = 12°C

7.37 kW

7.53 kW

COP Tj = 12°C

6.66

5.60

Cdh Tj = +12 °C

0.985

0.987

Pdh Tj = Tbiv

10.76 kW

9.50 kW

COP Tj = Tbiv

3.26

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.76 kW

9.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.26

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3009 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

123 %

Prated

9.15 kW

7.51 kW

SCOP

4.30

3.15

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.21 kW

6.97 kW

COP Tj = -7°C

2.67

1.76

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.83 kW

5.28 kW

COP Tj = +2°C

4.16

3.13

Cdh Tj = +2 °C

0.988

0.990

Pdh Tj = +7°C

6.96 kW

6.82 kW

COP Tj = +7°C

5.61

4.43

Cdh Tj = +7 °C

0.986

0.989

Pdh Tj = 12°C

7.09 kW

7.34 kW

COP Tj = 12°C

6.07

5.50

Cdh Tj = +12 °C

0.985

0.987

Pdh Tj = Tbiv

9.15 kW

7.51 kW

COP Tj = Tbiv

2.39

1.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.15 kW

7.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4389 kWh

4921 kWh

FHA-11/14-400V-M2 FS-e6-C2
Configure model
Model name
FHA-11/14-400V-M2 FS-e6-C2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.65 kW

14.40 kW

El input

3.32 kW

4.93 kW

COP

4.41

2.92

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.65 kW

4.86 kW

Cooling capacity

11.09

15.44

EER

2.39

3.18

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

11.09 kW

15.44 kW

SEER

4.45

5.56

Pdc Tj = 35°C

11.09 kW

15.44 kW

EER Tj = 35°C

2.39

3.18

Pdc Tj = 30°C

8.42 kW

11.59 kW

EER Tj = 30°C

3.68

4.92

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.62 kW

7.70 kW

EER Tj = 25°C

5.04

7.05

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

5.13 kW

6.50 kW

EER Tj = 20°C

5.17

6.42

Cdc Tj = 20 °C

0.983

0.983

Poff

14 W

14 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Annual energy consumption Qce

2378 kWh

2649 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

166 %

Prated

10.76 kW

9.50 kW

SCOP

5.74

4.22

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.76 kW

9.50 kW

COP Tj = +2°C

3.26

2.01

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.96 kW

7.40 kW

COP Tj = +7°C

5.51

3.63

Cdh Tj = +7 °C

0.900

0.992

Pdh Tj = 12°C

7.37 kW

7.53 kW

COP Tj = 12°C

6.66

5.60

Cdh Tj = +12 °C

0.985

0.987

Pdh Tj = Tbiv

10.76 kW

9.50 kW

COP Tj = Tbiv

3.26

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.76 kW

9.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.26

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3009 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

140 %

110 %

Prated

9.43 kW

8.80 kW

SCOP

3.56

2.82

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

6.03 kW

5.81 kW

COP Tj = -7°C

3.11

2.48

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.79 kW

5.51 kW

COP Tj = +2°C

4.25

3.52

Cdh Tj = +2 °C

0.988

0.989

Pdh Tj = +7°C

6.91 kW

6.89 kW

COP Tj = +7°C

5.69

4.82

Cdh Tj = +7 °C

0.986

0.988

Pdh Tj = 12°C

7.12 kW

7.79 kW

COP Tj = 12°C

6.04

6.48

Cdh Tj = +12 °C

0.986

0.986

Pdh Tj = Tbiv

7.69 kW

7.18 kW

COP Tj = Tbiv

2.16

1.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.67 kW

7.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.54

1.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.76 kW

8.80 kW

Annual energy consumption Qhe

6524 kWh

7485 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.69

7.18

COP Tj = -15°C (if TOL<-20°C)

2.16

1.58

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

11.55 kW

10.55 kW

SCOP

4.19

3.09

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.21 kW

9.34 kW

COP Tj = -7°C

2.67

1.84

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.09 kW

5.39 kW

COP Tj = +2°C

4.07

2.87

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.94 kW

6.95 kW

COP Tj = +7°C

5.65

4.65

Cdh Tj = +7 °C

0.986

0.989

Pdh Tj = 12°C

7.35 kW

7.67 kW

COP Tj = 12°C

6.77

6.16

Cdh Tj = +12 °C

0.984

0.986

Pdh Tj = Tbiv

10.21 kW

9.34 kW

COP Tj = Tbiv

2.67

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.15 kW

7.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.40 kW

3.04 kW

Annual energy consumption Qhe

5687 kWh

7048 kWh

FHA-14/17-400V-M2 FS-C2
Configure model
Model name
FHA-14/17-400V-M2 FS-C2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

17.02 kW

16.34 kW

El input

4.08 kW

5.73 kW

COP

4.17

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

5.28 kW

4.75 kW

Cooling capacity

12.91

15.84

EER

2.45

3.33

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.91 kW

15.84 kW

SEER

4.50

5.67

Pdc Tj = 35°C

12.91 kW

15.84 kW

EER Tj = 35°C

2.45

3.33

Pdc Tj = 30°C

9.77 kW

12.41 kW

EER Tj = 30°C

3.58

5.07

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

6.11 kW

7.09 kW

EER Tj = 25°C

5.02

7.12

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

5.14 kW

6.50 kW

EER Tj = 20°C

5.19

6.47

Cdc Tj = 20 °C

1.000

1.000

Poff

15 W

15 W

PTO

16 W

16 W

PSB

17 W

17 W

PCK

0 W

0 W

Annual energy consumption Qce

2736 kWh

2664 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

231 %

165 %

Prated

12.38 kW

10.34 kW

SCOP

5.86

4.19

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.38 kW

10.34 kW

COP Tj = +2°C

3.22

2.04

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.03 kW

7.06 kW

COP Tj = +7°C

5.62

3.56

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.43 kW

7.46 kW

COP Tj = 12°C

6.78

5.58

Cdh Tj = +12 °C

0.985

0.988

Pdh Tj = Tbiv

12.38 kW

10.34 kW

COP Tj = Tbiv

3.22

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.38 kW

10.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.22

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2822 kWh

3298 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

119 %

Prated

9.34 kW

7.71 kW

SCOP

4.37

3.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.96 kW

6.67 kW

COP Tj = -7°C

2.77

1.70

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.81 kW

5.06 kW

COP Tj = +2°C

4.18

3.06

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.22 kW

6.27 kW

COP Tj = +7°C

6.12

4.07

Cdh Tj = +7 °C

0.986

0.990

Pdh Tj = 12°C

7.35 kW

7.52 kW

COP Tj = 12°C

6.80

5.95

Cdh Tj = +12 °C

0.985

0.987

Pdh Tj = Tbiv

9.34 kW

7.71 kW

COP Tj = Tbiv

2.36

1.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.34 kW

7.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.36

1.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4413 kWh

5215 kWh

FHA-14/17-400V-M2 FS-e6-C2
Configure model
Model name
FHA-14/17-400V-M2 FS-e6-C2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

17.02 kW

16.34 kW

El input

4.08 kW

5.73 kW

COP

4.17

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

5.28 kW

4.75 kW

Cooling capacity

12.91

15.84

EER

2.45

3.33

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.91 kW

15.84 kW

SEER

4.50

5.67

Pdc Tj = 35°C

12.91 kW

15.84 kW

EER Tj = 35°C

2.45

3.33

Pdc Tj = 30°C

9.77 kW

12.41 kW

EER Tj = 30°C

3.58

5.07

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

6.11 kW

7.09 kW

EER Tj = 25°C

5.02

7.12

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

5.14 kW

6.50 kW

EER Tj = 20°C

5.19

6.47

Cdc Tj = 20 °C

1.000

1.000

Poff

15 W

15 W

PTO

16 W

16 W

PSB

17 W

17 W

PCK

0 W

0 W

Annual energy consumption Qce

2736 kWh

2664 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

231 %

165 %

Prated

12.38 kW

10.34 kW

SCOP

5.86

4.19

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.38 kW

10.34 kW

COP Tj = +2°C

3.22

2.04

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.03 kW

7.06 kW

COP Tj = +7°C

5.62

3.56

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.43 kW

7.46 kW

COP Tj = 12°C

6.78

5.58

Cdh Tj = +12 °C

0.985

0.988

Pdh Tj = Tbiv

12.38 kW

10.34 kW

COP Tj = Tbiv

3.22

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.38 kW

10.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.22

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2822 kWh

3298 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

146 %

105 %

Prated

9.93 kW

8.37 kW

SCOP

3.72

2.70

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

6.33 kW

5.24 kW

COP Tj = -7°C

3.22

2.37

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.98 kW

7.04 kW

COP Tj = +2°C

4.49

3.37

Cdh Tj = +2 °C

0.988

0.992

Pdh Tj = +7°C

7.20 kW

6.55 kW

COP Tj = +7°C

6.28

4.59

Cdh Tj = +7 °C

0.986

0.989

Pdh Tj = 12°C

7.43 kW

7.73 kW

COP Tj = 12°C

6.78

6.43

Cdh Tj = +12 °C

0.985

0.987

Pdh Tj = Tbiv

8.10 kW

6.83 kW

COP Tj = Tbiv

2.17

1.46

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.63 kW

6.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.53

1.46

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.29 kW

8.37 kW

Annual energy consumption Qhe

6570 kWh

7645 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.10

6.83

COP Tj = -15°C (if TOL<-20°C)

2.17

1.46

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

129 %

Prated

13.07 kW

11.73 kW

SCOP

4.40

3.30

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.56 kW

10.37 kW

COP Tj = -7°C

2.60

1.87

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.69 kW

6.06 kW

COP Tj = +2°C

4.32

3.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.19 kW

6.47 kW

COP Tj = +7°C

6.24

4.37

Cdh Tj = +7 °C

0.986

0.989

Pdh Tj = 12°C

7.42 kW

7.76 kW

COP Tj = 12°C

6.93

6.31

Cdh Tj = +12 °C

0.985

0.987

Pdh Tj = Tbiv

11.56 kW

10.37 kW

COP Tj = Tbiv

2.60

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.34 kW

7.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.36

1.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.73 kW

4.02 kW

Annual energy consumption Qhe

6131 kWh

7348 kWh

FHA-11/14-230V-M2 FS-e6-C2 + SEW-2-300 (FHA-11/14-230V-M2 FC-300-e6-C2; FHA-11/14-230V-M2 FC-300-R50-e6-C2; FHA-11/14-230V-M2 FC-300-S50-e6-C2)
Configure model
Model name
FHA-11/14-230V-M2 FS-e6-C2 + SEW-2-300 (FHA-11/14-230V-M2 FC-300-e6-C2; FHA-11/14-230V-M2 FC-300-R50-e6-C2; FHA-11/14-230V-M2 FC-300-S50-e6-C2)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.30 kW

13.56 kW

El input

3.09 kW

4.86 kW

COP

3.98

2.79

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.25 kW

3.17 kW

Cooling capacity

8.46

10.23

EER

1.99

3.23

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.45 kW

10.23 kW

SEER

4.41

5.65

Pdc Tj = 35°C

8.46 kW

10.23 kW

EER Tj = 35°C

1.99

3.23

Pdc Tj = 30°C

6.68 kW

8.16 kW

EER Tj = 30°C

3.71

5.34

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.10 kW

6.68 kW

EER Tj = 25°C

5.15

6.90

Cdc Tj = 25 °C

0.991

0.991

Pdc Tj = 20°C

4.98 kW

6.22 kW

EER Tj = 20°C

5.10

6.23

Cdc Tj = 20 °C

0.991

0.991

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

1829 kWh

1726 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

247 %

157 %

Prated

9.53 kW

8.41 kW

SCOP

6.24

4.00

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.53 kW

8.41 kW

COP Tj = +2°C

2.99

1.87

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.94 kW

6.95 kW

COP Tj = +7°C

5.75

3.37

Cdh Tj = +7 °C

0.993

0.996

Pdh Tj = 12°C

7.84 kW

7.18 kW

COP Tj = 12°C

7.68

5.36

Cdh Tj = +12 °C

0.991

0.993

Pdh Tj = Tbiv

9.53 kW

8.41 kW

COP Tj = Tbiv

2.99

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.53 kW

8.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.99

1.87

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2039 kWh

2811 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

147 %

101 %

Prated

8.88 kW

8.44 kW

SCOP

3.76

2.60

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

5.45 kW

5.23 kW

COP Tj = -7°C

3.42

2.01

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.73 kW

5.23 kW

COP Tj = +2°C

4.34

3.40

Cdh Tj = +2 °C

0.993

0.994

Pdh Tj = +7°C

7.36 kW

6.54 kW

COP Tj = +7°C

6.66

4.61

Cdh Tj = +7 °C

0.992

0.994

Pdh Tj = 12°C

7.74 kW

7.79 kW

COP Tj = 12°C

7.63

6.60

Cdh Tj = +12 °C

0.991

0.992

Pdh Tj = Tbiv

7.25 kW

6.88 kW

COP Tj = Tbiv

2.02

1.53

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.61 kW

6.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.53

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.27 kW

8.44 kW

Annual energy consumption Qhe

5822 kWh

8014 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.25

6.88

COP Tj = -15°C (if TOL<-20°C)

2.02

1.53

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

174 %

126 %

Prated

11.25 kW

9.15 kW

SCOP

4.43

3.22

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.95 kW

8.10 kW

COP Tj = -7°C

2.61

1.74

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.13 kW

5.18 kW

COP Tj = +2°C

4.25

3.24

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.17 kW

6.38 kW

COP Tj = +7°C

6.34

4.22

Cdh Tj = +7 °C

0.992

0.994

Pdh Tj = 12°C

7.76 kW

7.51 kW

COP Tj = 12°C

7.81

6.08

Cdh Tj = +12 °C

0.991

0.993

Pdh Tj = Tbiv

9.95 kW

8.10 kW

COP Tj = Tbiv

2.61

1.74

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.66 kW

8.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.29

1.63

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.59 kW

1.14 kW

Annual energy consumption Qhe

5250 kWh

5880 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

130 %

COP

3.25

Heating up time

2:03 h:min

Standby power input

54.2 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

315 l

Colder Climate

Average Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

108 %

COP

2.71

Heating up time

1:55 h:min

Standby power input

61.9 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

312 l

FHA-14/17-230V-M2 FS-e6-C2 + SEW-2-300 (FHA-14/17-230V-M2 FC-300-S50-e6-C2)
Configure model
Model name
FHA-14/17-230V-M2 FS-e6-C2 + SEW-2-300 (FHA-14/17-230V-M2 FC-300-S50-e6-C2)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.98 kW

14.78 kW

El input

4.07 kW

5.11 kW

COP

4.17

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.12 kW

4.90 kW

Cooling capacity

10.38

15.52

EER

2.52

3.17

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.38 kW

15.52 kW

SEER

4.48

5.92

Pdc Tj = 35°C

10.38 kW

15.52 kW

EER Tj = 35°C

2.52

3.17

Pdc Tj = 30°C

7.82 kW

10.98 kW

EER Tj = 30°C

3.73

5.15

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

4.89 kW

7.14 kW

EER Tj = 25°C

4.71

7.61

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

4.90 kW

6.37 kW

EER Tj = 20°C

5.15

6.54

Cdc Tj = 20 °C

0.990

0.990

Poff

7 W

7 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Annual energy consumption Qce

2210 kWh

2501 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

261 %

164 %

Prated

12.26 kW

10.23 kW

SCOP

6.60

4.17

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.26 kW

10.23 kW

COP Tj = +2°C

3.20

2.04

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.20 kW

6.88 kW

COP Tj = +7°C

6.00

3.53

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.99 kW

7.17 kW

COP Tj = 12°C

8.17

5.52

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

12.26 kW

10.23 kW

COP Tj = Tbiv

3.20

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.20

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2479 kWh

3277 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

108 %

Prated

9.78 kW

10.62 kW

SCOP

3.96

2.78

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

5.81 kW

6.13 kW

COP Tj = -7°C

3.41

2.28

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.75 kW

5.20 kW

COP Tj = +2°C

4.92

3.52

Cdh Tj = +2 °C

0.992

0.993

Pdh Tj = +7°C

7.07 kW

6.47 kW

COP Tj = +7°C

6.49

4.71

Cdh Tj = +7 °C

0.991

0.993

Pdh Tj = 12°C

8.01 kW

7.43 kW

COP Tj = 12°C

8.30

6.41

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

7.98 kW

8.67 kW

COP Tj = Tbiv

2.14

1.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.65 kW

8.67 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.53

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.13 kW

10.62 kW

Annual energy consumption Qhe

6081 kWh

9423 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.98

8.67

COP Tj = -15°C (if TOL<-20°C)

2.14

1.79

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

131 %

Prated

13.04 kW

12.09 kW

SCOP

4.52

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.53 kW

10.69 kW

COP Tj = -7°C

2.56

2.05

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.99 kW

6.92 kW

COP Tj = +2°C

4.40

3.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.04 kW

6.37 kW

COP Tj = +7°C

6.38

4.43

Cdh Tj = +7 °C

0.991

0.993

Pdh Tj = 12°C

7.99 kW

7.34 kW

COP Tj = 12°C

8.40

6.08

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

11.53 kW

10.69 kW

COP Tj = Tbiv

2.56

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.89 kW

6.68 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.14 kW

5.41 kW

Annual energy consumption Qhe

5959 kWh

7443 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

130 %

COP

3.25

Heating up time

2:03 h:min

Standby power input

54.2 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

315 l

Colder Climate

Average Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

108 %

COP

2.71

Heating up time

1:55 h:min

Standby power input

61.9 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

312 l

FHA-11/14-400V-M2 FS-e6-C2 + SEW-2-300 (FHA-11/14-400V-M2 FC-300-e6-C2 ; FHA-11/14-400V FC-300-R50-e6-C2; FHA-11/14-400V FC-300-S50-e6-C2)
Configure model
Model name
FHA-11/14-400V-M2 FS-e6-C2 + SEW-2-300 (FHA-11/14-400V-M2 FC-300-e6-C2 ; FHA-11/14-400V FC-300-R50-e6-C2; FHA-11/14-400V FC-300-S50-e6-C2)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.65 kW

14.40 kW

El input

3.32 kW

4.93 kW

COP

4.41

2.92

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.65 kW

4.86 kW

Cooling capacity

11.09

15.44

EER

2.39

3.18

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

11.09 kW

15.44 kW

SEER

4.45

5.56

Pdc Tj = 35°C

11.09 kW

15.44 kW

EER Tj = 35°C

2.39

3.18

Pdc Tj = 30°C

8.42 kW

11.59 kW

EER Tj = 30°C

3.68

4.92

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.62 kW

7.70 kW

EER Tj = 25°C

5.04

7.05

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

5.13 kW

6.50 kW

EER Tj = 20°C

5.17

6.42

Cdc Tj = 20 °C

0.983

0.983

Poff

14 W

14 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Annual energy consumption Qce

2378 kWh

2649 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

166 %

Prated

10.76 kW

9.50 kW

SCOP

5.74

4.22

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.76 kW

9.50 kW

COP Tj = +2°C

3.26

2.01

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.96 kW

7.40 kW

COP Tj = +7°C

5.51

3.63

Cdh Tj = +7 °C

0.900

0.992

Pdh Tj = 12°C

7.37 kW

7.53 kW

COP Tj = 12°C

6.66

5.60

Cdh Tj = +12 °C

0.985

0.987

Pdh Tj = Tbiv

10.76 kW

9.50 kW

COP Tj = Tbiv

3.26

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.76 kW

9.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.26

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3009 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

140 %

110 %

Prated

9.43 kW

8.80 kW

SCOP

3.56

2.82

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

6.03 kW

5.81 kW

COP Tj = -7°C

3.11

2.48

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.79 kW

5.51 kW

COP Tj = +2°C

4.25

3.52

Cdh Tj = +2 °C

0.988

0.989

Pdh Tj = +7°C

6.91 kW

6.89 kW

COP Tj = +7°C

5.69

4.82

Cdh Tj = +7 °C

0.986

0.988

Pdh Tj = 12°C

7.12 kW

7.79 kW

COP Tj = 12°C

6.04

6.48

Cdh Tj = +12 °C

0.986

0.986

Pdh Tj = Tbiv

7.69 kW

7.18 kW

COP Tj = Tbiv

2.16

1.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.67 kW

7.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.54

1.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.76 kW

8.80 kW

Annual energy consumption Qhe

6524 kWh

7485 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.69

7.18

COP Tj = -15°C (if TOL<-20°C)

2.16

1.58

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

11.55 kW

10.55 kW

SCOP

4.19

3.09

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.21 kW

9.34 kW

COP Tj = -7°C

2.67

1.84

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.09 kW

5.39 kW

COP Tj = +2°C

4.07

2.87

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.94 kW

6.95 kW

COP Tj = +7°C

5.65

4.65

Cdh Tj = +7 °C

0.986

0.989

Pdh Tj = 12°C

7.35 kW

7.67 kW

COP Tj = 12°C

6.77

6.16

Cdh Tj = +12 °C

0.984

0.986

Pdh Tj = Tbiv

10.21 kW

9.34 kW

COP Tj = Tbiv

2.67

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.15 kW

7.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.40 kW

3.04 kW

Annual energy consumption Qhe

5687 kWh

7048 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

128 %

COP

3.19

Heating up time

2:07 h:min

Standby power input

63.6 W

Reference hot water temperature

49.6 °C

Mixed water at 40°C

311 l

Colder Climate

Average Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

104 %

COP

2.59

Heating up time

2:04 h:min

Standby power input

75.4 W

Reference hot water temperature

49.6 °C

Mixed water at 40°C

311 l

FHA-14/17-400V-M2 FS-e6-C2 + SEW-2-300 (FHA-14/17-400V FC-300-S50-e6-C2)
Configure model
Model name
FHA-14/17-400V-M2 FS-e6-C2 + SEW-2-300 (FHA-14/17-400V FC-300-S50-e6-C2)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

17.02 kW

16.34 kW

El input

4.08 kW

5.73 kW

COP

4.17

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

5.28 kW

4.75 kW

Cooling capacity

12.91

15.84

EER

2.45

3.33

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.91 kW

15.84 kW

SEER

4.50

5.67

Pdc Tj = 35°C

12.91 kW

15.84 kW

EER Tj = 35°C

2.45

3.33

Pdc Tj = 30°C

9.77 kW

12.41 kW

EER Tj = 30°C

3.58

5.07

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

6.11 kW

7.09 kW

EER Tj = 25°C

5.02

7.12

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

5.14 kW

6.50 kW

EER Tj = 20°C

5.19

6.47

Cdc Tj = 20 °C

1.000

1.000

Poff

15 W

15 W

PTO

16 W

16 W

PSB

17 W

17 W

PCK

0 W

0 W

Annual energy consumption Qce

2736 kWh

2664 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

231 %

165 %

Prated

12.38 kW

10.34 kW

SCOP

5.86

4.19

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.38 kW

10.34 kW

COP Tj = +2°C

3.22

2.04

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.03 kW

7.06 kW

COP Tj = +7°C

5.62

3.56

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.43 kW

7.46 kW

COP Tj = 12°C

6.78

5.58

Cdh Tj = +12 °C

0.985

0.988

Pdh Tj = Tbiv

12.38 kW

10.34 kW

COP Tj = Tbiv

3.22

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.38 kW

10.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.22

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2822 kWh

3298 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

146 %

105 %

Prated

9.93 kW

8.37 kW

SCOP

3.72

2.70

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

6.33 kW

5.24 kW

COP Tj = -7°C

3.22

2.37

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.98 kW

7.04 kW

COP Tj = +2°C

4.49

3.37

Cdh Tj = +2 °C

0.988

0.992

Pdh Tj = +7°C

7.20 kW

6.55 kW

COP Tj = +7°C

6.28

4.59

Cdh Tj = +7 °C

0.986

0.989

Pdh Tj = 12°C

7.43 kW

7.73 kW

COP Tj = 12°C

6.78

6.43

Cdh Tj = +12 °C

0.985

0.987

Pdh Tj = Tbiv

8.10 kW

6.83 kW

COP Tj = Tbiv

2.17

1.46

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.63 kW

6.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.53

1.46

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.29 kW

8.37 kW

Annual energy consumption Qhe

6570 kWh

7645 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.10

6.83

COP Tj = -15°C (if TOL<-20°C)

2.17

1.46

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

129 %

Prated

13.07 kW

11.73 kW

SCOP

4.40

3.30

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.56 kW

10.37 kW

COP Tj = -7°C

2.60

1.87

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.69 kW

6.06 kW

COP Tj = +2°C

4.32

3.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.19 kW

6.47 kW

COP Tj = +7°C

6.24

4.37

Cdh Tj = +7 °C

0.986

0.989

Pdh Tj = 12°C

7.42 kW

7.76 kW

COP Tj = 12°C

6.93

6.31

Cdh Tj = +12 °C

0.985

0.987

Pdh Tj = Tbiv

11.56 kW

10.37 kW

COP Tj = Tbiv

2.60

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.34 kW

7.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.36

1.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.73 kW

4.02 kW

Annual energy consumption Qhe

6131 kWh

7348 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

128 %

COP

3.19

Heating up time

2:07 h:min

Standby power input

63.6 W

Reference hot water temperature

49.6 °C

Mixed water at 40°C

311 l

Colder Climate

Average Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

104 %

COP

2.59

Heating up time

2:04 h:min

Standby power input

75.4 W

Reference hot water temperature

49.6 °C

Mixed water at 40°C

311 l