1,750 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.30 kW
13.56 kW
El input
3.09 kW
4.86 kW
COP
3.98
2.79
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.25 kW
3.17 kW
Cooling capacity
8.46
10.23
EER
1.99
3.23
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
8.45 kW
10.23 kW
SEER
4.41
5.65
Pdc Tj = 35°C
8.46 kW
10.23 kW
EER Tj = 35°C
1.99
3.23
Pdc Tj = 30°C
6.68 kW
8.16 kW
EER Tj = 30°C
3.71
5.34
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
5.10 kW
6.68 kW
EER Tj = 25°C
5.15
6.90
Cdc Tj = 25 °C
0.991
0.991
Pdc Tj = 20°C
4.98 kW
6.22 kW
EER Tj = 20°C
5.10
6.23
Cdc Tj = 20 °C
0.991
0.991
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
1829 kWh
1726 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
247 %
157 %
Prated
9.53 kW
8.41 kW
SCOP
6.24
4.00
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.53 kW
8.41 kW
COP Tj = +2°C
2.99
1.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.94 kW
6.95 kW
COP Tj = +7°C
5.75
3.37
Cdh Tj = +7 °C
0.993
0.996
Pdh Tj = 12°C
7.84 kW
7.18 kW
COP Tj = 12°C
7.68
5.36
Cdh Tj = +12 °C
0.991
0.993
Pdh Tj = Tbiv
9.53 kW
8.41 kW
COP Tj = Tbiv
2.99
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.53 kW
8.41 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
1.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2039 kWh
2811 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
174 %
122 %
Prated
8.66 kW
8.01 kW
SCOP
4.42
3.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.63 kW
6.52 kW
COP Tj = -7°C
2.76
1.65
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.58 kW
5.13 kW
COP Tj = +2°C
4.15
3.12
Cdh Tj = +2 °C
0.993
0.995
Pdh Tj = +7°C
7.11 kW
6.36 kW
COP Tj = +7°C
6.18
4.16
Cdh Tj = +7 °C
0.992
0.994
Pdh Tj = 12°C
7.78 kW
7.44 kW
COP Tj = 12°C
7.72
6.00
Cdh Tj = +12 °C
0.991
0.993
Pdh Tj = Tbiv
8.66 kW
8.01 kW
COP Tj = Tbiv
2.29
1.63
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.66 kW
8.01 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.29
1.63
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4053 kWh
5312 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.30 kW
13.56 kW
El input
3.09 kW
4.86 kW
COP
3.98
2.79
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.25 kW
3.17 kW
Cooling capacity
8.46
10.23
EER
1.99
3.23
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
8.45 kW
10.23 kW
SEER
4.41
5.65
Pdc Tj = 35°C
8.46 kW
10.23 kW
EER Tj = 35°C
1.99
3.23
Pdc Tj = 30°C
6.68 kW
8.16 kW
EER Tj = 30°C
3.71
5.34
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
5.10 kW
6.68 kW
EER Tj = 25°C
5.15
6.90
Cdc Tj = 25 °C
0.991
0.991
Pdc Tj = 20°C
4.98 kW
6.22 kW
EER Tj = 20°C
5.10
6.23
Cdc Tj = 20 °C
0.991
0.991
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
1829 kWh
1726 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
247 %
157 %
Prated
9.53 kW
8.41 kW
SCOP
6.24
4.00
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.53 kW
8.41 kW
COP Tj = +2°C
2.99
1.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.94 kW
6.95 kW
COP Tj = +7°C
5.75
3.37
Cdh Tj = +7 °C
0.993
0.996
Pdh Tj = 12°C
7.84 kW
7.18 kW
COP Tj = 12°C
7.68
5.36
Cdh Tj = +12 °C
0.991
0.993
Pdh Tj = Tbiv
9.53 kW
8.41 kW
COP Tj = Tbiv
2.99
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.53 kW
8.41 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
1.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2039 kWh
2811 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
147 %
101 %
Prated
8.88 kW
8.44 kW
SCOP
3.76
2.60
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-15 °C
Pdh Tj = -7°C
5.45 kW
5.23 kW
COP Tj = -7°C
3.42
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.73 kW
5.23 kW
COP Tj = +2°C
4.34
3.40
Cdh Tj = +2 °C
0.993
0.994
Pdh Tj = +7°C
7.36 kW
6.54 kW
COP Tj = +7°C
6.66
4.61
Cdh Tj = +7 °C
0.992
0.994
Pdh Tj = 12°C
7.74 kW
7.79 kW
COP Tj = 12°C
7.63
6.60
Cdh Tj = +12 °C
0.991
0.992
Pdh Tj = Tbiv
7.25 kW
6.88 kW
COP Tj = Tbiv
2.02
1.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.61 kW
6.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.53
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.27 kW
8.44 kW
Annual energy consumption Qhe
5822 kWh
8014 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.25
6.88
COP Tj = -15°C (if TOL<-20°C)
2.02
1.53
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
174 %
126 %
Prated
11.25 kW
9.15 kW
SCOP
4.43
3.22
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.95 kW
8.10 kW
COP Tj = -7°C
2.61
1.74
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.13 kW
5.18 kW
COP Tj = +2°C
4.25
3.24
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.17 kW
6.38 kW
COP Tj = +7°C
6.34
4.22
Cdh Tj = +7 °C
0.992
0.994
Pdh Tj = 12°C
7.76 kW
7.51 kW
COP Tj = 12°C
7.81
6.08
Cdh Tj = +12 °C
0.991
0.993
Pdh Tj = Tbiv
9.95 kW
8.10 kW
COP Tj = Tbiv
2.61
1.74
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.66 kW
8.01 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.29
1.63
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.59 kW
1.14 kW
Annual energy consumption Qhe
5250 kWh
5880 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.98 kW
14.78 kW
El input
4.07 kW
5.11 kW
COP
4.17
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.12 kW
4.90 kW
Cooling capacity
10.38
15.52
EER
2.52
3.17
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
10.38 kW
15.52 kW
SEER
4.48
5.92
Pdc Tj = 35°C
10.38 kW
15.52 kW
EER Tj = 35°C
2.52
3.17
Pdc Tj = 30°C
7.82 kW
10.98 kW
EER Tj = 30°C
3.73
5.15
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
4.89 kW
7.14 kW
EER Tj = 25°C
4.71
7.61
Cdc Tj = 25 °C
0.250
0.250
Pdc Tj = 20°C
4.90 kW
6.37 kW
EER Tj = 20°C
5.15
6.54
Cdc Tj = 20 °C
0.990
0.990
Poff
7 W
7 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
2210 kWh
2501 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
261 %
164 %
Prated
12.26 kW
10.23 kW
SCOP
6.60
4.17
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.26 kW
10.23 kW
COP Tj = +2°C
3.20
2.04
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.20 kW
6.88 kW
COP Tj = +7°C
6.00
3.53
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.99 kW
7.17 kW
COP Tj = 12°C
8.17
5.52
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
12.26 kW
10.23 kW
COP Tj = Tbiv
3.20
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.26 kW
10.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.20
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2479 kWh
3277 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
122 %
Prated
9.89 kW
6.68 kW
SCOP
4.82
3.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.38 kW
8.94 kW
COP Tj = -7°C
2.83
2.00
Cdh Tj = -7 °C
0.900
0.998
Pdh Tj = +2°C
5.76 kW
4.94 kW
COP Tj = +2°C
4.81
2.99
Cdh Tj = +2 °C
0.900
0.994
Pdh Tj = +7°C
7.00 kW
6.21 kW
COP Tj = +7°C
6.19
4.08
Cdh Tj = +7 °C
0.991
0.994
Pdh Tj = 12°C
7.99 kW
7.29 kW
COP Tj = 12°C
8.33
5.92
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
9.89 kW
6.68 kW
COP Tj = Tbiv
2.41
1.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.89 kW
6.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.41
1.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4243 kWh
4430 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.98 kW
14.78 kW
El input
4.07 kW
5.11 kW
COP
4.17
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.12 kW
4.90 kW
Cooling capacity
10.38
15.52
EER
2.52
3.17
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
10.38 kW
15.52 kW
SEER
4.48
5.92
Pdc Tj = 35°C
10.38 kW
15.52 kW
EER Tj = 35°C
2.52
3.17
Pdc Tj = 30°C
7.82 kW
10.98 kW
EER Tj = 30°C
3.73
5.15
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
4.89 kW
7.14 kW
EER Tj = 25°C
4.71
7.61
Cdc Tj = 25 °C
0.250
0.250
Pdc Tj = 20°C
4.90 kW
6.37 kW
EER Tj = 20°C
5.15
6.54
Cdc Tj = 20 °C
0.990
0.990
Poff
7 W
7 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
2210 kWh
2501 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
261 %
164 %
Prated
12.26 kW
10.23 kW
SCOP
6.60
4.17
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.26 kW
10.23 kW
COP Tj = +2°C
3.20
2.04
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.20 kW
6.88 kW
COP Tj = +7°C
6.00
3.53
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.99 kW
7.17 kW
COP Tj = 12°C
8.17
5.52
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
12.26 kW
10.23 kW
COP Tj = Tbiv
3.20
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.26 kW
10.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.20
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2479 kWh
3277 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
108 %
Prated
9.78 kW
10.62 kW
SCOP
3.96
2.78
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-15 °C
Pdh Tj = -7°C
5.81 kW
6.13 kW
COP Tj = -7°C
3.41
2.28
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.75 kW
5.20 kW
COP Tj = +2°C
4.92
3.52
Cdh Tj = +2 °C
0.992
0.993
Pdh Tj = +7°C
7.07 kW
6.47 kW
COP Tj = +7°C
6.49
4.71
Cdh Tj = +7 °C
0.991
0.993
Pdh Tj = 12°C
8.01 kW
7.43 kW
COP Tj = 12°C
8.30
6.41
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
7.98 kW
8.67 kW
COP Tj = Tbiv
2.14
1.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.65 kW
8.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.53
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.13 kW
10.62 kW
Annual energy consumption Qhe
6081 kWh
9423 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.98
8.67
COP Tj = -15°C (if TOL<-20°C)
2.14
1.79
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
131 %
Prated
13.04 kW
12.09 kW
SCOP
4.52
3.36
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.53 kW
10.69 kW
COP Tj = -7°C
2.56
2.05
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.99 kW
6.92 kW
COP Tj = +2°C
4.40
3.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.04 kW
6.37 kW
COP Tj = +7°C
6.38
4.43
Cdh Tj = +7 °C
0.991
0.993
Pdh Tj = 12°C
7.99 kW
7.34 kW
COP Tj = 12°C
8.40
6.08
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
11.53 kW
10.69 kW
COP Tj = Tbiv
2.56
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.89 kW
6.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.41
1.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.14 kW
5.41 kW
Annual energy consumption Qhe
5959 kWh
7443 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.65 kW
14.40 kW
El input
3.32 kW
4.93 kW
COP
4.41
2.92
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.65 kW
4.86 kW
Cooling capacity
11.09
15.44
EER
2.39
3.18
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
11.09 kW
15.44 kW
SEER
4.45
5.56
Pdc Tj = 35°C
11.09 kW
15.44 kW
EER Tj = 35°C
2.39
3.18
Pdc Tj = 30°C
8.42 kW
11.59 kW
EER Tj = 30°C
3.68
4.92
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
5.62 kW
7.70 kW
EER Tj = 25°C
5.04
7.05
Cdc Tj = 25 °C
0.250
0.250
Pdc Tj = 20°C
5.13 kW
6.50 kW
EER Tj = 20°C
5.17
6.42
Cdc Tj = 20 °C
0.983
0.983
Poff
14 W
14 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Annual energy consumption Qce
2378 kWh
2649 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
227 %
166 %
Prated
10.76 kW
9.50 kW
SCOP
5.74
4.22
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.76 kW
9.50 kW
COP Tj = +2°C
3.26
2.01
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.96 kW
7.40 kW
COP Tj = +7°C
5.51
3.63
Cdh Tj = +7 °C
0.900
0.992
Pdh Tj = 12°C
7.37 kW
7.53 kW
COP Tj = 12°C
6.66
5.60
Cdh Tj = +12 °C
0.985
0.987
Pdh Tj = Tbiv
10.76 kW
9.50 kW
COP Tj = Tbiv
3.26
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.76 kW
9.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.26
2.01
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3009 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
123 %
Prated
9.15 kW
7.51 kW
SCOP
4.30
3.15
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.21 kW
6.97 kW
COP Tj = -7°C
2.67
1.76
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.83 kW
5.28 kW
COP Tj = +2°C
4.16
3.13
Cdh Tj = +2 °C
0.988
0.990
Pdh Tj = +7°C
6.96 kW
6.82 kW
COP Tj = +7°C
5.61
4.43
Cdh Tj = +7 °C
0.986
0.989
Pdh Tj = 12°C
7.09 kW
7.34 kW
COP Tj = 12°C
6.07
5.50
Cdh Tj = +12 °C
0.985
0.987
Pdh Tj = Tbiv
9.15 kW
7.51 kW
COP Tj = Tbiv
2.39
1.39
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.15 kW
7.51 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.39
1.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4389 kWh
4921 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.65 kW
14.40 kW
El input
3.32 kW
4.93 kW
COP
4.41
2.92
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.65 kW
4.86 kW
Cooling capacity
11.09
15.44
EER
2.39
3.18
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
11.09 kW
15.44 kW
SEER
4.45
5.56
Pdc Tj = 35°C
11.09 kW
15.44 kW
EER Tj = 35°C
2.39
3.18
Pdc Tj = 30°C
8.42 kW
11.59 kW
EER Tj = 30°C
3.68
4.92
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
5.62 kW
7.70 kW
EER Tj = 25°C
5.04
7.05
Cdc Tj = 25 °C
0.250
0.250
Pdc Tj = 20°C
5.13 kW
6.50 kW
EER Tj = 20°C
5.17
6.42
Cdc Tj = 20 °C
0.983
0.983
Poff
14 W
14 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Annual energy consumption Qce
2378 kWh
2649 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
227 %
166 %
Prated
10.76 kW
9.50 kW
SCOP
5.74
4.22
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.76 kW
9.50 kW
COP Tj = +2°C
3.26
2.01
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.96 kW
7.40 kW
COP Tj = +7°C
5.51
3.63
Cdh Tj = +7 °C
0.900
0.992
Pdh Tj = 12°C
7.37 kW
7.53 kW
COP Tj = 12°C
6.66
5.60
Cdh Tj = +12 °C
0.985
0.987
Pdh Tj = Tbiv
10.76 kW
9.50 kW
COP Tj = Tbiv
3.26
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.76 kW
9.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.26
2.01
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3009 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
140 %
110 %
Prated
9.43 kW
8.80 kW
SCOP
3.56
2.82
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-15 °C
Pdh Tj = -7°C
6.03 kW
5.81 kW
COP Tj = -7°C
3.11
2.48
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.79 kW
5.51 kW
COP Tj = +2°C
4.25
3.52
Cdh Tj = +2 °C
0.988
0.989
Pdh Tj = +7°C
6.91 kW
6.89 kW
COP Tj = +7°C
5.69
4.82
Cdh Tj = +7 °C
0.986
0.988
Pdh Tj = 12°C
7.12 kW
7.79 kW
COP Tj = 12°C
6.04
6.48
Cdh Tj = +12 °C
0.986
0.986
Pdh Tj = Tbiv
7.69 kW
7.18 kW
COP Tj = Tbiv
2.16
1.58
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.67 kW
7.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.54
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.76 kW
8.80 kW
Annual energy consumption Qhe
6524 kWh
7485 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.69
7.18
COP Tj = -15°C (if TOL<-20°C)
2.16
1.58
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
11.55 kW
10.55 kW
SCOP
4.19
3.09
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.21 kW
9.34 kW
COP Tj = -7°C
2.67
1.84
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.09 kW
5.39 kW
COP Tj = +2°C
4.07
2.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.94 kW
6.95 kW
COP Tj = +7°C
5.65
4.65
Cdh Tj = +7 °C
0.986
0.989
Pdh Tj = 12°C
7.35 kW
7.67 kW
COP Tj = 12°C
6.77
6.16
Cdh Tj = +12 °C
0.984
0.986
Pdh Tj = Tbiv
10.21 kW
9.34 kW
COP Tj = Tbiv
2.67
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.15 kW
7.51 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.39
1.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.40 kW
3.04 kW
Annual energy consumption Qhe
5687 kWh
7048 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
17.02 kW
16.34 kW
El input
4.08 kW
5.73 kW
COP
4.17
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
5.28 kW
4.75 kW
Cooling capacity
12.91
15.84
EER
2.45
3.33
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
12.91 kW
15.84 kW
SEER
4.50
5.67
Pdc Tj = 35°C
12.91 kW
15.84 kW
EER Tj = 35°C
2.45
3.33
Pdc Tj = 30°C
9.77 kW
12.41 kW
EER Tj = 30°C
3.58
5.07
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
6.11 kW
7.09 kW
EER Tj = 25°C
5.02
7.12
Cdc Tj = 25 °C
0.250
0.250
Pdc Tj = 20°C
5.14 kW
6.50 kW
EER Tj = 20°C
5.19
6.47
Cdc Tj = 20 °C
1.000
1.000
Poff
15 W
15 W
PTO
16 W
16 W
PSB
17 W
17 W
PCK
0 W
0 W
Annual energy consumption Qce
2736 kWh
2664 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
231 %
165 %
Prated
12.38 kW
10.34 kW
SCOP
5.86
4.19
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.38 kW
10.34 kW
COP Tj = +2°C
3.22
2.04
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.03 kW
7.06 kW
COP Tj = +7°C
5.62
3.56
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.43 kW
7.46 kW
COP Tj = 12°C
6.78
5.58
Cdh Tj = +12 °C
0.985
0.988
Pdh Tj = Tbiv
12.38 kW
10.34 kW
COP Tj = Tbiv
3.22
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.38 kW
10.34 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.22
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2822 kWh
3298 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
172 %
119 %
Prated
9.34 kW
7.71 kW
SCOP
4.37
3.05
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.96 kW
6.67 kW
COP Tj = -7°C
2.77
1.70
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.81 kW
5.06 kW
COP Tj = +2°C
4.18
3.06
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.22 kW
6.27 kW
COP Tj = +7°C
6.12
4.07
Cdh Tj = +7 °C
0.986
0.990
Pdh Tj = 12°C
7.35 kW
7.52 kW
COP Tj = 12°C
6.80
5.95
Cdh Tj = +12 °C
0.985
0.987
Pdh Tj = Tbiv
9.34 kW
7.71 kW
COP Tj = Tbiv
2.36
1.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.34 kW
7.71 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4413 kWh
5215 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
17.02 kW
16.34 kW
El input
4.08 kW
5.73 kW
COP
4.17
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
5.28 kW
4.75 kW
Cooling capacity
12.91
15.84
EER
2.45
3.33
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
12.91 kW
15.84 kW
SEER
4.50
5.67
Pdc Tj = 35°C
12.91 kW
15.84 kW
EER Tj = 35°C
2.45
3.33
Pdc Tj = 30°C
9.77 kW
12.41 kW
EER Tj = 30°C
3.58
5.07
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
6.11 kW
7.09 kW
EER Tj = 25°C
5.02
7.12
Cdc Tj = 25 °C
0.250
0.250
Pdc Tj = 20°C
5.14 kW
6.50 kW
EER Tj = 20°C
5.19
6.47
Cdc Tj = 20 °C
1.000
1.000
Poff
15 W
15 W
PTO
16 W
16 W
PSB
17 W
17 W
PCK
0 W
0 W
Annual energy consumption Qce
2736 kWh
2664 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
231 %
165 %
Prated
12.38 kW
10.34 kW
SCOP
5.86
4.19
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.38 kW
10.34 kW
COP Tj = +2°C
3.22
2.04
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.03 kW
7.06 kW
COP Tj = +7°C
5.62
3.56
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.43 kW
7.46 kW
COP Tj = 12°C
6.78
5.58
Cdh Tj = +12 °C
0.985
0.988
Pdh Tj = Tbiv
12.38 kW
10.34 kW
COP Tj = Tbiv
3.22
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.38 kW
10.34 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.22
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2822 kWh
3298 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
146 %
105 %
Prated
9.93 kW
8.37 kW
SCOP
3.72
2.70
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-15 °C
Pdh Tj = -7°C
6.33 kW
5.24 kW
COP Tj = -7°C
3.22
2.37
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.98 kW
7.04 kW
COP Tj = +2°C
4.49
3.37
Cdh Tj = +2 °C
0.988
0.992
Pdh Tj = +7°C
7.20 kW
6.55 kW
COP Tj = +7°C
6.28
4.59
Cdh Tj = +7 °C
0.986
0.989
Pdh Tj = 12°C
7.43 kW
7.73 kW
COP Tj = 12°C
6.78
6.43
Cdh Tj = +12 °C
0.985
0.987
Pdh Tj = Tbiv
8.10 kW
6.83 kW
COP Tj = Tbiv
2.17
1.46
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.63 kW
6.83 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.53
1.46
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.29 kW
8.37 kW
Annual energy consumption Qhe
6570 kWh
7645 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.10
6.83
COP Tj = -15°C (if TOL<-20°C)
2.17
1.46
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
173 %
129 %
Prated
13.07 kW
11.73 kW
SCOP
4.40
3.30
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.56 kW
10.37 kW
COP Tj = -7°C
2.60
1.87
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.69 kW
6.06 kW
COP Tj = +2°C
4.32
3.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.19 kW
6.47 kW
COP Tj = +7°C
6.24
4.37
Cdh Tj = +7 °C
0.986
0.989
Pdh Tj = 12°C
7.42 kW
7.76 kW
COP Tj = 12°C
6.93
6.31
Cdh Tj = +12 °C
0.985
0.987
Pdh Tj = Tbiv
11.56 kW
10.37 kW
COP Tj = Tbiv
2.60
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.34 kW
7.71 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.73 kW
4.02 kW
Annual energy consumption Qhe
6131 kWh
7348 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.30 kW
13.56 kW
El input
3.09 kW
4.86 kW
COP
3.98
2.79
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.25 kW
3.17 kW
Cooling capacity
8.46
10.23
EER
1.99
3.23
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
8.45 kW
10.23 kW
SEER
4.41
5.65
Pdc Tj = 35°C
8.46 kW
10.23 kW
EER Tj = 35°C
1.99
3.23
Pdc Tj = 30°C
6.68 kW
8.16 kW
EER Tj = 30°C
3.71
5.34
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
5.10 kW
6.68 kW
EER Tj = 25°C
5.15
6.90
Cdc Tj = 25 °C
0.991
0.991
Pdc Tj = 20°C
4.98 kW
6.22 kW
EER Tj = 20°C
5.10
6.23
Cdc Tj = 20 °C
0.991
0.991
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
1829 kWh
1726 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
247 %
157 %
Prated
9.53 kW
8.41 kW
SCOP
6.24
4.00
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.53 kW
8.41 kW
COP Tj = +2°C
2.99
1.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.94 kW
6.95 kW
COP Tj = +7°C
5.75
3.37
Cdh Tj = +7 °C
0.993
0.996
Pdh Tj = 12°C
7.84 kW
7.18 kW
COP Tj = 12°C
7.68
5.36
Cdh Tj = +12 °C
0.991
0.993
Pdh Tj = Tbiv
9.53 kW
8.41 kW
COP Tj = Tbiv
2.99
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.53 kW
8.41 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
1.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2039 kWh
2811 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
147 %
101 %
Prated
8.88 kW
8.44 kW
SCOP
3.76
2.60
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-15 °C
Pdh Tj = -7°C
5.45 kW
5.23 kW
COP Tj = -7°C
3.42
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.73 kW
5.23 kW
COP Tj = +2°C
4.34
3.40
Cdh Tj = +2 °C
0.993
0.994
Pdh Tj = +7°C
7.36 kW
6.54 kW
COP Tj = +7°C
6.66
4.61
Cdh Tj = +7 °C
0.992
0.994
Pdh Tj = 12°C
7.74 kW
7.79 kW
COP Tj = 12°C
7.63
6.60
Cdh Tj = +12 °C
0.991
0.992
Pdh Tj = Tbiv
7.25 kW
6.88 kW
COP Tj = Tbiv
2.02
1.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.61 kW
6.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.53
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.27 kW
8.44 kW
Annual energy consumption Qhe
5822 kWh
8014 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.25
6.88
COP Tj = -15°C (if TOL<-20°C)
2.02
1.53
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
174 %
126 %
Prated
11.25 kW
9.15 kW
SCOP
4.43
3.22
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.95 kW
8.10 kW
COP Tj = -7°C
2.61
1.74
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.13 kW
5.18 kW
COP Tj = +2°C
4.25
3.24
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.17 kW
6.38 kW
COP Tj = +7°C
6.34
4.22
Cdh Tj = +7 °C
0.992
0.994
Pdh Tj = 12°C
7.76 kW
7.51 kW
COP Tj = 12°C
7.81
6.08
Cdh Tj = +12 °C
0.991
0.993
Pdh Tj = Tbiv
9.95 kW
8.10 kW
COP Tj = Tbiv
2.61
1.74
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.66 kW
8.01 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.29
1.63
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.59 kW
1.14 kW
Annual energy consumption Qhe
5250 kWh
5880 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XXL
Efficiency ηDHW
130 %
COP
3.25
Heating up time
2:03 h:min
Standby power input
54.2 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
315 l
Colder Climate
Average Climate
EN 16147
Declared load profile
XXL
Efficiency ηDHW
108 %
COP
2.71
Heating up time
1:55 h:min
Standby power input
61.9 W
Reference hot water temperature
49.8 °C
Mixed water at 40°C
312 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.98 kW
14.78 kW
El input
4.07 kW
5.11 kW
COP
4.17
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.12 kW
4.90 kW
Cooling capacity
10.38
15.52
EER
2.52
3.17
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
10.38 kW
15.52 kW
SEER
4.48
5.92
Pdc Tj = 35°C
10.38 kW
15.52 kW
EER Tj = 35°C
2.52
3.17
Pdc Tj = 30°C
7.82 kW
10.98 kW
EER Tj = 30°C
3.73
5.15
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
4.89 kW
7.14 kW
EER Tj = 25°C
4.71
7.61
Cdc Tj = 25 °C
0.250
0.250
Pdc Tj = 20°C
4.90 kW
6.37 kW
EER Tj = 20°C
5.15
6.54
Cdc Tj = 20 °C
0.990
0.990
Poff
7 W
7 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
2210 kWh
2501 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
261 %
164 %
Prated
12.26 kW
10.23 kW
SCOP
6.60
4.17
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.26 kW
10.23 kW
COP Tj = +2°C
3.20
2.04
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.20 kW
6.88 kW
COP Tj = +7°C
6.00
3.53
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.99 kW
7.17 kW
COP Tj = 12°C
8.17
5.52
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
12.26 kW
10.23 kW
COP Tj = Tbiv
3.20
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.26 kW
10.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.20
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2479 kWh
3277 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
108 %
Prated
9.78 kW
10.62 kW
SCOP
3.96
2.78
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-15 °C
Pdh Tj = -7°C
5.81 kW
6.13 kW
COP Tj = -7°C
3.41
2.28
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.75 kW
5.20 kW
COP Tj = +2°C
4.92
3.52
Cdh Tj = +2 °C
0.992
0.993
Pdh Tj = +7°C
7.07 kW
6.47 kW
COP Tj = +7°C
6.49
4.71
Cdh Tj = +7 °C
0.991
0.993
Pdh Tj = 12°C
8.01 kW
7.43 kW
COP Tj = 12°C
8.30
6.41
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
7.98 kW
8.67 kW
COP Tj = Tbiv
2.14
1.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.65 kW
8.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.53
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.13 kW
10.62 kW
Annual energy consumption Qhe
6081 kWh
9423 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.98
8.67
COP Tj = -15°C (if TOL<-20°C)
2.14
1.79
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
131 %
Prated
13.04 kW
12.09 kW
SCOP
4.52
3.36
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.53 kW
10.69 kW
COP Tj = -7°C
2.56
2.05
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.99 kW
6.92 kW
COP Tj = +2°C
4.40
3.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.04 kW
6.37 kW
COP Tj = +7°C
6.38
4.43
Cdh Tj = +7 °C
0.991
0.993
Pdh Tj = 12°C
7.99 kW
7.34 kW
COP Tj = 12°C
8.40
6.08
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
11.53 kW
10.69 kW
COP Tj = Tbiv
2.56
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.89 kW
6.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.41
1.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.14 kW
5.41 kW
Annual energy consumption Qhe
5959 kWh
7443 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XXL
Efficiency ηDHW
130 %
COP
3.25
Heating up time
2:03 h:min
Standby power input
54.2 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
315 l
Colder Climate
Average Climate
EN 16147
Declared load profile
XXL
Efficiency ηDHW
108 %
COP
2.71
Heating up time
1:55 h:min
Standby power input
61.9 W
Reference hot water temperature
49.8 °C
Mixed water at 40°C
312 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.65 kW
14.40 kW
El input
3.32 kW
4.93 kW
COP
4.41
2.92
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.65 kW
4.86 kW
Cooling capacity
11.09
15.44
EER
2.39
3.18
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
11.09 kW
15.44 kW
SEER
4.45
5.56
Pdc Tj = 35°C
11.09 kW
15.44 kW
EER Tj = 35°C
2.39
3.18
Pdc Tj = 30°C
8.42 kW
11.59 kW
EER Tj = 30°C
3.68
4.92
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
5.62 kW
7.70 kW
EER Tj = 25°C
5.04
7.05
Cdc Tj = 25 °C
0.250
0.250
Pdc Tj = 20°C
5.13 kW
6.50 kW
EER Tj = 20°C
5.17
6.42
Cdc Tj = 20 °C
0.983
0.983
Poff
14 W
14 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Annual energy consumption Qce
2378 kWh
2649 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
227 %
166 %
Prated
10.76 kW
9.50 kW
SCOP
5.74
4.22
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.76 kW
9.50 kW
COP Tj = +2°C
3.26
2.01
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.96 kW
7.40 kW
COP Tj = +7°C
5.51
3.63
Cdh Tj = +7 °C
0.900
0.992
Pdh Tj = 12°C
7.37 kW
7.53 kW
COP Tj = 12°C
6.66
5.60
Cdh Tj = +12 °C
0.985
0.987
Pdh Tj = Tbiv
10.76 kW
9.50 kW
COP Tj = Tbiv
3.26
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.76 kW
9.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.26
2.01
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3009 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
140 %
110 %
Prated
9.43 kW
8.80 kW
SCOP
3.56
2.82
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-15 °C
Pdh Tj = -7°C
6.03 kW
5.81 kW
COP Tj = -7°C
3.11
2.48
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.79 kW
5.51 kW
COP Tj = +2°C
4.25
3.52
Cdh Tj = +2 °C
0.988
0.989
Pdh Tj = +7°C
6.91 kW
6.89 kW
COP Tj = +7°C
5.69
4.82
Cdh Tj = +7 °C
0.986
0.988
Pdh Tj = 12°C
7.12 kW
7.79 kW
COP Tj = 12°C
6.04
6.48
Cdh Tj = +12 °C
0.986
0.986
Pdh Tj = Tbiv
7.69 kW
7.18 kW
COP Tj = Tbiv
2.16
1.58
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.67 kW
7.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.54
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.76 kW
8.80 kW
Annual energy consumption Qhe
6524 kWh
7485 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.69
7.18
COP Tj = -15°C (if TOL<-20°C)
2.16
1.58
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
11.55 kW
10.55 kW
SCOP
4.19
3.09
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.21 kW
9.34 kW
COP Tj = -7°C
2.67
1.84
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.09 kW
5.39 kW
COP Tj = +2°C
4.07
2.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.94 kW
6.95 kW
COP Tj = +7°C
5.65
4.65
Cdh Tj = +7 °C
0.986
0.989
Pdh Tj = 12°C
7.35 kW
7.67 kW
COP Tj = 12°C
6.77
6.16
Cdh Tj = +12 °C
0.984
0.986
Pdh Tj = Tbiv
10.21 kW
9.34 kW
COP Tj = Tbiv
2.67
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.15 kW
7.51 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.39
1.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.40 kW
3.04 kW
Annual energy consumption Qhe
5687 kWh
7048 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XXL
Efficiency ηDHW
128 %
COP
3.19
Heating up time
2:07 h:min
Standby power input
63.6 W
Reference hot water temperature
49.6 °C
Mixed water at 40°C
311 l
Colder Climate
Average Climate
EN 16147
Declared load profile
XXL
Efficiency ηDHW
104 %
COP
2.59
Heating up time
2:04 h:min
Standby power input
75.4 W
Reference hot water temperature
49.6 °C
Mixed water at 40°C
311 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
17.02 kW
16.34 kW
El input
4.08 kW
5.73 kW
COP
4.17
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
5.28 kW
4.75 kW
Cooling capacity
12.91
15.84
EER
2.45
3.33
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
12.91 kW
15.84 kW
SEER
4.50
5.67
Pdc Tj = 35°C
12.91 kW
15.84 kW
EER Tj = 35°C
2.45
3.33
Pdc Tj = 30°C
9.77 kW
12.41 kW
EER Tj = 30°C
3.58
5.07
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
6.11 kW
7.09 kW
EER Tj = 25°C
5.02
7.12
Cdc Tj = 25 °C
0.250
0.250
Pdc Tj = 20°C
5.14 kW
6.50 kW
EER Tj = 20°C
5.19
6.47
Cdc Tj = 20 °C
1.000
1.000
Poff
15 W
15 W
PTO
16 W
16 W
PSB
17 W
17 W
PCK
0 W
0 W
Annual energy consumption Qce
2736 kWh
2664 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
231 %
165 %
Prated
12.38 kW
10.34 kW
SCOP
5.86
4.19
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.38 kW
10.34 kW
COP Tj = +2°C
3.22
2.04
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.03 kW
7.06 kW
COP Tj = +7°C
5.62
3.56
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.43 kW
7.46 kW
COP Tj = 12°C
6.78
5.58
Cdh Tj = +12 °C
0.985
0.988
Pdh Tj = Tbiv
12.38 kW
10.34 kW
COP Tj = Tbiv
3.22
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.38 kW
10.34 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.22
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2822 kWh
3298 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
146 %
105 %
Prated
9.93 kW
8.37 kW
SCOP
3.72
2.70
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-15 °C
Pdh Tj = -7°C
6.33 kW
5.24 kW
COP Tj = -7°C
3.22
2.37
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.98 kW
7.04 kW
COP Tj = +2°C
4.49
3.37
Cdh Tj = +2 °C
0.988
0.992
Pdh Tj = +7°C
7.20 kW
6.55 kW
COP Tj = +7°C
6.28
4.59
Cdh Tj = +7 °C
0.986
0.989
Pdh Tj = 12°C
7.43 kW
7.73 kW
COP Tj = 12°C
6.78
6.43
Cdh Tj = +12 °C
0.985
0.987
Pdh Tj = Tbiv
8.10 kW
6.83 kW
COP Tj = Tbiv
2.17
1.46
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.63 kW
6.83 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.53
1.46
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.29 kW
8.37 kW
Annual energy consumption Qhe
6570 kWh
7645 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.10
6.83
COP Tj = -15°C (if TOL<-20°C)
2.17
1.46
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
173 %
129 %
Prated
13.07 kW
11.73 kW
SCOP
4.40
3.30
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.56 kW
10.37 kW
COP Tj = -7°C
2.60
1.87
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.69 kW
6.06 kW
COP Tj = +2°C
4.32
3.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.19 kW
6.47 kW
COP Tj = +7°C
6.24
4.37
Cdh Tj = +7 °C
0.986
0.989
Pdh Tj = 12°C
7.42 kW
7.76 kW
COP Tj = 12°C
6.93
6.31
Cdh Tj = +12 °C
0.985
0.987
Pdh Tj = Tbiv
11.56 kW
10.37 kW
COP Tj = Tbiv
2.60
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.34 kW
7.71 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.73 kW
4.02 kW
Annual energy consumption Qhe
6131 kWh
7348 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XXL
Efficiency ηDHW
128 %
COP
3.19
Heating up time
2:07 h:min
Standby power input
63.6 W
Reference hot water temperature
49.6 °C
Mixed water at 40°C
311 l
Colder Climate
Average Climate
EN 16147
Declared load profile
XXL
Efficiency ηDHW
104 %
COP
2.59
Heating up time
2:04 h:min
Standby power input
75.4 W
Reference hot water temperature
49.6 °C
Mixed water at 40°C