Certificate holders

Subtype

FHA-Monoblock 8-10kW

Certificate Holder
WOLF GmbH
Industriestr. 1
84048 Mainburg
Germany
Registration number
011-1W0559
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
FHA-Monoblock 8-10kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,400 kg

Certification Date
17.10.2022
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 10 (as of 2022-06)
Generate PDF Export model CSV
  • Number of models 3

Models

FHA-08/10-230V-M2 FS-B2
Configure model
Model name
FHA-08/10-230V-M2 FS-B2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.73 kW

9.69 kW

El input

2.29 kW

3.38 kW

COP

4.69

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.66 kW

2.22 kW

Cooling capacity

8.10

9.72

EER

3.04

4.38

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.10 kW

9.72 kW

SEER

3.72

5.46

Pdc Tj = 35°C

8.10 kW

9.72 kW

EER Tj = 35°C

3.04

4.38

Pdc Tj = 30°C

5.85 kW

6.87 kW

EER Tj = 30°C

4.13

6.10

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

3.74 kW

4.64 kW

EER Tj = 25°C

4.46

7.73

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

3.41 kW

4.25 kW

EER Tj = 20°C

5.81

7.44

Cdc Tj = 20 °C

0.983

0.983

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Annual energy consumption Qce

2077 kWh

1698 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

166 %

Prated

8.33 kW

7.22 kW

SCOP

6.55

4.23

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.33 kW

7.22 kW

COP Tj = +2°C

3.69

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.62 kW

4.96 kW

COP Tj = +7°C

5.91

3.64

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.89 kW

4.22 kW

COP Tj = 12°C

8.00

5.44

Cdh Tj = +12 °C

0.984

0.987

Pdh Tj = Tbiv

8.33 kW

7.22 kW

COP Tj = Tbiv

3.69

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.33 kW

7.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.69

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1699 kWh

2280 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

119 %

Prated

6.95 kW

3.59 kW

SCOP

4.95

3.06

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.39 kW

4.45 kW

COP Tj = -7°C

3.27

1.98

Cdh Tj = -7 °C

0.900

0.996

Pdh Tj = +2°C

3.92 kW

4.11 kW

COP Tj = +2°C

4.82

2.98

Cdh Tj = +2 °C

0.900

0.993

Pdh Tj = +7°C

3.78 kW

4.51 kW

COP Tj = +7°C

6.30

4.06

Cdh Tj = +7 °C

0.984

0.991

Pdh Tj = 12°C

4.89 kW

4.26 kW

COP Tj = 12°C

8.00

5.71

Cdh Tj = +12 °C

0.984

0.987

Pdh Tj = Tbiv

6.95 kW

3.59 kW

COP Tj = Tbiv

2.70

1.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.95 kW

3.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

1.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2896 kWh

2427 kWh

FHA-08/10-230V-M2 FS-e6-B2
Configure model
Model name
FHA-08/10-230V-M2 FS-e6-B2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.73 kW

9.69 kW

El input

2.29 kW

3.38 kW

COP

4.69

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.66 kW

2.22 kW

Cooling capacity

8.10

9.72

EER

3.04

4.38

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.10 kW

9.72 kW

SEER

3.72

5.46

Pdc Tj = 35°C

8.10 kW

9.72 kW

EER Tj = 35°C

3.04

4.38

Pdc Tj = 30°C

5.85 kW

6.87 kW

EER Tj = 30°C

4.13

6.10

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

3.74 kW

4.64 kW

EER Tj = 25°C

4.46

7.73

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

3.41 kW

4.25 kW

EER Tj = 20°C

5.81

7.44

Cdc Tj = 20 °C

0.983

0.983

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Annual energy consumption Qce

2077 kWh

1698 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

166 %

Prated

8.33 kW

7.22 kW

SCOP

6.55

4.23

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.33 kW

7.22 kW

COP Tj = +2°C

3.69

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.62 kW

4.96 kW

COP Tj = +7°C

5.91

3.64

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.89 kW

4.22 kW

COP Tj = 12°C

8.00

5.44

Cdh Tj = +12 °C

0.984

0.987

Pdh Tj = Tbiv

8.33 kW

7.22 kW

COP Tj = Tbiv

3.69

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.33 kW

7.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.69

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1699 kWh

2280 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

158 %

112 %

Prated

7.82 kW

7.19 kW

SCOP

4.03

2.86

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

4.82 kW

4.53 kW

COP Tj = -7°C

3.62

2.52

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.85 kW

2.88 kW

COP Tj = +2°C

4.54

3.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.79 kW

3.53 kW

COP Tj = +7°C

6.52

4.62

Cdh Tj = +7 °C

0.983

0.987

Pdh Tj = 12°C

4.89 kW

4.56 kW

COP Tj = 12°C

8.06

6.57

Cdh Tj = +12 °C

0.984

0.986

Pdh Tj = Tbiv

6.38 kW

5.87 kW

COP Tj = Tbiv

2.55

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.36 kW

5.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.05

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.46 kW

7.19 kW

Annual energy consumption Qhe

4784 kWh

6187 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.38

5.87

COP Tj = -15°C (if TOL<-20°C)

2.55

1.92

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

133 %

Prated

8.62 kW

8.17 kW

SCOP

4.98

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.63 kW

7.22 kW

COP Tj = -7°C

2.97

2.13

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.53 kW

4.53 kW

COP Tj = +2°C

5.01

3.41

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.81 kW

3.50 kW

COP Tj = +7°C

6.49

4.39

Cdh Tj = +7 °C

0.983

0.988

Pdh Tj = 12°C

4.90 kW

4.35 kW

COP Tj = 12°C

8.15

6.07

Cdh Tj = +12 °C

0.984

0.986

Pdh Tj = Tbiv

7.63 kW

7.22 kW

COP Tj = Tbiv

2.97

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.95 kW

3.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

1.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.68 kW

4.57 kW

Annual energy consumption Qhe

3576 kWh

4949 kWh

FHA-08/10-230V-M2 FS-e6-B2 + CEW-2-200 (FHA-08/10-230V-M2 FC-200-e6-B2; FHA-08/10-230V-M2 FC-200-R35-e6-B2)
Configure model
Model name
FHA-08/10-230V-M2 FS-e6-B2 + CEW-2-200 (FHA-08/10-230V-M2 FC-200-e6-B2; FHA-08/10-230V-M2 FC-200-R35-e6-B2)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.73 kW

9.69 kW

El input

2.29 kW

3.38 kW

COP

4.69

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.66 kW

2.22 kW

Cooling capacity

8.10

9.72

EER

3.04

4.38

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.10 kW

9.72 kW

SEER

3.72

5.46

Pdc Tj = 35°C

8.10 kW

9.72 kW

EER Tj = 35°C

3.04

4.38

Pdc Tj = 30°C

5.85 kW

6.87 kW

EER Tj = 30°C

4.13

6.10

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

3.74 kW

4.64 kW

EER Tj = 25°C

4.46

7.73

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

3.41 kW

4.25 kW

EER Tj = 20°C

5.81

7.44

Cdc Tj = 20 °C

0.983

0.983

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Annual energy consumption Qce

2077 kWh

1698 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

166 %

Prated

8.33 kW

7.22 kW

SCOP

6.55

4.23

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.33 kW

7.22 kW

COP Tj = +2°C

3.69

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.62 kW

4.96 kW

COP Tj = +7°C

5.91

3.64

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.89 kW

4.22 kW

COP Tj = 12°C

8.00

5.44

Cdh Tj = +12 °C

0.984

0.987

Pdh Tj = Tbiv

8.33 kW

7.22 kW

COP Tj = Tbiv

3.69

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.33 kW

7.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.69

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1699 kWh

2280 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

158 %

112 %

Prated

7.82 kW

7.19 kW

SCOP

4.03

2.86

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

4.82 kW

4.53 kW

COP Tj = -7°C

3.62

2.52

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.85 kW

2.88 kW

COP Tj = +2°C

4.54

3.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.79 kW

3.53 kW

COP Tj = +7°C

6.52

4.62

Cdh Tj = +7 °C

0.983

0.987

Pdh Tj = 12°C

4.89 kW

4.56 kW

COP Tj = 12°C

8.06

6.57

Cdh Tj = +12 °C

0.984

0.986

Pdh Tj = Tbiv

6.38 kW

5.87 kW

COP Tj = Tbiv

2.55

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.36 kW

5.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.05

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.46 kW

7.19 kW

Annual energy consumption Qhe

4784 kWh

6187 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.38

5.87

COP Tj = -15°C (if TOL<-20°C)

2.55

1.92

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

133 %

Prated

8.62 kW

8.17 kW

SCOP

4.98

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.63 kW

7.22 kW

COP Tj = -7°C

2.97

2.13

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.53 kW

4.53 kW

COP Tj = +2°C

5.01

3.41

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.81 kW

3.50 kW

COP Tj = +7°C

6.49

4.39

Cdh Tj = +7 °C

0.983

0.988

Pdh Tj = 12°C

4.90 kW

4.35 kW

COP Tj = 12°C

8.15

6.07

Cdh Tj = +12 °C

0.984

0.986

Pdh Tj = Tbiv

7.63 kW

7.22 kW

COP Tj = Tbiv

2.97

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.95 kW

3.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

1.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.68 kW

4.57 kW

Annual energy consumption Qhe

3576 kWh

4949 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

140 %

COP

3.35

Heating up time

1:59 h:min

Standby power input

43.6 W

Reference hot water temperature

51.7 °C

Mixed water at 40°C

237 l

Colder Climate

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.66

Heating up time

2:06 h:min

Standby power input

42.8 W

Reference hot water temperature

51.9 °C

Mixed water at 40°C

233 l