Certificate holders

Subtype

Platinum BC Mural iR32 12-16 & Platinum BC Integra iR32 12-16 & Platinum BC Mural Hybrid iR32 12-16

Certificate Holder
BAXI Climatización S.L.U
López de Hoyos 35
28002 Madrid
Spain
Registration number
007-DN0146
Certification Body
Kiwa Nederland B.V.
Subtype title
Platinum BC Mural iR32 12-16 & Platinum BC Integra iR32 12-16 & Platinum BC Mural Hybrid iR32 12-16
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,840 kg

Certification Date
11.11.2022
Testing basis
European KEYMARK Scheme for Heat Pumps (v10)
Generate PDF Export model CSV Download certificate
  • Number of models 12

Models

Platinum BC Integra 12EM iR32
Configure model
Model name
Platinum BC Integra 12EM iR32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.00 kW

El input

2.44 kW

3.87 kW

COP

4.95

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

10.55 kW

10.77 kW

Cooling capacity

4.19

2.92

EER

2.52

3.69

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.55 kW

10.77 kW

SEER

4.09

6.66

Pdc Tj = 35°C

10.55 kW

10.77 kW

EER Tj = 35°C

2.52

3.69

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

7.78 kW

7.88 kW

EER Tj = 30°C

3.58

5.39

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.17 kW

5.20 kW

EER Tj = 25°C

4.57

7.93

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.24 kW

3.03 kW

EER Tj = 20°C

5.05

9.28

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1548 kWh

971 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

135 %

Prated

12.00 kW

11.58 kW

SCOP

4.52

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.61 kW

10.25 kW

COP Tj = -7°C

2.88

2.01

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.48 kW

6.52 kW

COP Tj = +2°C

4.30

3.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.44 kW

4.36 kW

COP Tj = +7°C

6.00

4.59

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.74 kW

3.30 kW

COP Tj = 12°C

8.47

6.05

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.61 kW

10.25 kW

COP Tj = Tbiv

2.88

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.75 kW

9.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.26 kW

2.50 kW

Annual energy consumption Qhe

5482 kWh

6919 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.60

Heating up time

0:57 h:min

Standby power input

35.1 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

248 l

Platinum BC Integra 16EM iR32
Configure model
Model name
Platinum BC Integra 16EM iR32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.56 kW

5.52 kW

COP

4.50

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

12.36 kW

11.63 kW

Cooling capacity

5.44

3.22

EER

2.27

3.61

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.36 kW

11.63 kW

SEER

4.23

6.19

Pdc Tj = 35°C

12.36 kW

11.63 kW

EER Tj = 35°C

2.27

3.61

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

9.40 kW

8.67 kW

EER Tj = 30°C

3.41

5.22

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.89 kW

5.39 kW

EER Tj = 25°C

4.89

7.78

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.81 kW

2.48 kW

EER Tj = 20°C

5.80

6.89

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1754 kWh

1128 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

133 %

Prated

15.21 kW

13.02 kW

SCOP

4.50

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.45 kW

11.52 kW

COP Tj = -7°C

2.72

1.99

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.20 kW

7.18 kW

COP Tj = +2°C

4.30

3.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.70 kW

4.56 kW

COP Tj = +7°C

6.20

4.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.78 kW

3.32 kW

COP Tj = 12°C

8.51

6.07

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.45 kW

11.52 kW

COP Tj = Tbiv

2.72

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.52 kW

10.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.68 kW

2.67 kW

Annual energy consumption Qhe

6979 kWh

7890 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.60

Heating up time

0:57 h:min

Standby power input

35.1 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

248 l

Platinum BC Mural 12EM iR32
Configure model
Model name
Platinum BC Mural 12EM iR32
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.00 kW

El input

2.44 kW

3.87 kW

COP

4.95

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

10.55 kW

10.77 kW

Cooling capacity

4.19

2.92

EER

2.52

3.69

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.55 kW

10.77 kW

SEER

4.09

6.66

Pdc Tj = 35°C

10.55 kW

10.77 kW

EER Tj = 35°C

2.52

3.69

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

7.78 kW

7.88 kW

EER Tj = 30°C

3.58

5.39

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.17 kW

5.20 kW

EER Tj = 25°C

4.57

7.93

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.24 kW

3.03 kW

EER Tj = 20°C

5.05

9.28

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1548 kWh

971 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

135 %

Prated

12.00 kW

11.58 kW

SCOP

4.52

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.61 kW

10.25 kW

COP Tj = -7°C

2.88

2.01

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.48 kW

6.52 kW

COP Tj = +2°C

4.30

3.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.44 kW

4.36 kW

COP Tj = +7°C

6.00

4.59

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.74 kW

3.30 kW

COP Tj = 12°C

8.47

6.05

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.61 kW

10.25 kW

COP Tj = Tbiv

2.88

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.75 kW

9.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.26 kW

2.50 kW

Annual energy consumption Qhe

5482 kWh

6919 kWh

Platinum BC Mural 16EM iR32
Configure model
Model name
Platinum BC Mural 16EM iR32
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.56 kW

5.52 kW

COP

4.50

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

12.36 kW

11.63 kW

Cooling capacity

5.44

3.22

EER

2.27

3.61

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.36 kW

11.63 kW

SEER

4.23

6.19

Pdc Tj = 35°C

12.36 kW

11.63 kW

EER Tj = 35°C

2.27

3.61

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

9.40 kW

8.67 kW

EER Tj = 30°C

3.41

5.22

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.89 kW

5.39 kW

EER Tj = 25°C

4.89

7.78

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.81 kW

2.48 kW

EER Tj = 20°C

5.80

6.89

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1754 kWh

1128 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

133 %

Prated

15.21 kW

13.02 kW

SCOP

4.50

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.45 kW

11.52 kW

COP Tj = -7°C

2.72

1.99

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.20 kW

7.18 kW

COP Tj = +2°C

4.30

3.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.70 kW

4.56 kW

COP Tj = +7°C

6.20

4.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.78 kW

3.32 kW

COP Tj = 12°C

8.51

6.07

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.45 kW

11.52 kW

COP Tj = Tbiv

2.72

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.52 kW

10.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.68 kW

2.67 kW

Annual energy consumption Qhe

6979 kWh

7890 kWh

Platinum BC Mural Hybrid 12EM iR32
Configure model
Model name
Platinum BC Mural Hybrid 12EM iR32
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.00 kW

El input

2.44 kW

3.87 kW

COP

4.95

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

10.55 kW

10.77 kW

Cooling capacity

4.19

2.92

EER

2.52

3.69

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.55 kW

10.77 kW

SEER

4.09

6.66

Pdc Tj = 35°C

10.55 kW

10.77 kW

EER Tj = 35°C

2.52

3.69

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

7.78 kW

7.88 kW

EER Tj = 30°C

3.58

5.39

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.17 kW

5.20 kW

EER Tj = 25°C

4.57

7.93

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.24 kW

3.03 kW

EER Tj = 20°C

5.05

9.28

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1548 kWh

971 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

135 %

Prated

12.00 kW

11.58 kW

SCOP

4.52

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.61 kW

10.25 kW

COP Tj = -7°C

2.88

2.01

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.48 kW

6.52 kW

COP Tj = +2°C

4.30

3.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.44 kW

4.36 kW

COP Tj = +7°C

6.00

4.59

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.74 kW

3.30 kW

COP Tj = 12°C

8.47

6.05

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.61 kW

10.25 kW

COP Tj = Tbiv

2.88

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.75 kW

9.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.26 kW

2.50 kW

Annual energy consumption Qhe

5482 kWh

6919 kWh

Platinum BC Mural Hybrid 16EM iR32
Configure model
Model name
Platinum BC Mural Hybrid 16EM iR32
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.56 kW

5.52 kW

COP

4.50

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

12.36 kW

11.63 kW

Cooling capacity

5.44

3.22

EER

2.27

3.61

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.36 kW

11.63 kW

SEER

4.23

6.19

Pdc Tj = 35°C

12.36 kW

11.63 kW

EER Tj = 35°C

2.27

3.61

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

9.40 kW

8.67 kW

EER Tj = 30°C

3.41

5.22

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.89 kW

5.39 kW

EER Tj = 25°C

4.89

7.78

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.81 kW

2.48 kW

EER Tj = 20°C

5.80

6.89

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1754 kWh

1128 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

133 %

Prated

15.21 kW

13.02 kW

SCOP

4.50

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.45 kW

11.52 kW

COP Tj = -7°C

2.72

1.99

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.20 kW

7.18 kW

COP Tj = +2°C

4.30

3.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.70 kW

4.56 kW

COP Tj = +7°C

6.20

4.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.78 kW

3.32 kW

COP Tj = 12°C

8.51

6.07

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.45 kW

11.52 kW

COP Tj = Tbiv

2.72

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.52 kW

10.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.68 kW

2.67 kW

Annual energy consumption Qhe

6979 kWh

7890 kWh

Platinum BC Integra 12ET iR32
Configure model
Model name
Platinum BC Integra 12ET iR32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.00 kW

El input

2.44 kW

3.87 kW

COP

4.95

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

10.55 kW

10.77 kW

Cooling capacity

4.19

2.92

EER

2.52

3.69

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.55 kW

10.77 kW

SEER

4.09

6.66

Pdc Tj = 35°C

10.55 kW

10.77 kW

EER Tj = 35°C

2.52

3.69

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

7.78 kW

7.88 kW

EER Tj = 30°C

3.58

5.39

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.17 kW

5.20 kW

EER Tj = 25°C

4.57

7.93

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.24 kW

3.03 kW

EER Tj = 20°C

5.05

9.28

Cdc Tj = 20 °C

0.900

0.900

Poff

20 W

20 W

PTO

10 W

10 W

PSB

20 W

20 W

PCK

0 W

0 W

Annual energy consumption Qce

1548 kWh

971 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

135 %

Prated

12.00 kW

11.58 kW

SCOP

4.52

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.61 kW

10.25 kW

COP Tj = -7°C

2.88

2.01

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.48 kW

6.52 kW

COP Tj = +2°C

4.30

3.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.44 kW

4.36 kW

COP Tj = +7°C

6.00

4.59

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.74 kW

3.30 kW

COP Tj = 12°C

8.47

6.05

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.61 kW

10.25 kW

COP Tj = Tbiv

2.88

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.75 kW

9.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.26 kW

2.50 kW

Annual energy consumption Qhe

5482 kWh

6919 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.60

Heating up time

0:57 h:min

Standby power input

35.1 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

248 l

Platinum BC Integra 16ET iR32
Configure model
Model name
Platinum BC Integra 16ET iR32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.56 kW

5.52 kW

COP

4.50

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

12.36 kW

11.63 kW

Cooling capacity

5.44

3.22

EER

2.27

3.61

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.36 kW

11.63 kW

SEER

4.23

6.19

Pdc Tj = 35°C

12.36 kW

11.63 kW

EER Tj = 35°C

2.27

3.61

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

9.40 kW

8.67 kW

EER Tj = 30°C

3.41

5.22

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.89 kW

5.39 kW

EER Tj = 25°C

4.89

7.78

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.81 kW

2.48 kW

EER Tj = 20°C

5.80

6.89

Cdc Tj = 20 °C

0.900

0.900

Poff

20 W

20 W

PTO

10 W

10 W

PSB

20 W

20 W

PCK

0 W

0 W

Annual energy consumption Qce

1754 kWh

1128 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

133 %

Prated

15.21 kW

13.02 kW

SCOP

4.50

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.45 kW

11.52 kW

COP Tj = -7°C

2.72

1.99

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.20 kW

7.18 kW

COP Tj = +2°C

4.30

3.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.70 kW

4.56 kW

COP Tj = +7°C

6.20

4.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.78 kW

3.32 kW

COP Tj = 12°C

8.51

6.07

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.45 kW

11.52 kW

COP Tj = Tbiv

2.72

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.52 kW

10.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.68 kW

2.67 kW

Annual energy consumption Qhe

6979 kWh

7890 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.60

Heating up time

0:57 h:min

Standby power input

35.1 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

248 l

Platinum BC Mural 12ET iR32
Configure model
Model name
Platinum BC Mural 12ET iR32
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.00 kW

El input

2.44 kW

3.87 kW

COP

4.95

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

10.55 kW

10.77 kW

Cooling capacity

4.19

2.92

EER

2.52

3.69

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.55 kW

10.77 kW

SEER

4.09

6.66

Pdc Tj = 35°C

10.55 kW

10.77 kW

EER Tj = 35°C

2.52

3.69

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

7.78 kW

7.88 kW

EER Tj = 30°C

3.58

5.39

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.17 kW

5.20 kW

EER Tj = 25°C

4.57

7.93

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.24 kW

3.03 kW

EER Tj = 20°C

5.05

9.28

Cdc Tj = 20 °C

0.900

0.900

Poff

20 W

20 W

PTO

10 W

10 W

PSB

20 W

20 W

PCK

0 W

0 W

Annual energy consumption Qce

1548 kWh

971 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

135 %

Prated

12.00 kW

11.58 kW

SCOP

4.52

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.61 kW

10.25 kW

COP Tj = -7°C

2.88

2.01

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.48 kW

6.52 kW

COP Tj = +2°C

4.30

3.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.44 kW

4.36 kW

COP Tj = +7°C

6.00

4.59

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.74 kW

3.30 kW

COP Tj = 12°C

8.47

6.05

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.61 kW

10.25 kW

COP Tj = Tbiv

2.88

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.75 kW

9.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.26 kW

2.50 kW

Annual energy consumption Qhe

5482 kWh

6919 kWh

Platinum BC Mural 16ET iR32
Configure model
Model name
Platinum BC Mural 16ET iR32
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.56 kW

5.52 kW

COP

4.50

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

12.36 kW

11.63 kW

Cooling capacity

5.44

3.22

EER

2.27

3.61

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.36 kW

11.63 kW

SEER

4.23

6.19

Pdc Tj = 35°C

12.36 kW

11.63 kW

EER Tj = 35°C

2.27

3.61

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

9.40 kW

8.67 kW

EER Tj = 30°C

3.41

5.22

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.89 kW

5.39 kW

EER Tj = 25°C

4.89

7.78

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.81 kW

2.48 kW

EER Tj = 20°C

5.80

6.89

Cdc Tj = 20 °C

0.900

0.900

Poff

20 W

20 W

PTO

10 W

10 W

PSB

20 W

20 W

PCK

0 W

0 W

Annual energy consumption Qce

1754 kWh

1128 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

133 %

Prated

15.21 kW

13.02 kW

SCOP

4.50

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.45 kW

11.52 kW

COP Tj = -7°C

2.72

1.99

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.20 kW

7.18 kW

COP Tj = +2°C

4.30

3.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.70 kW

4.56 kW

COP Tj = +7°C

6.20

4.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.78 kW

3.32 kW

COP Tj = 12°C

8.51

6.07

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.45 kW

11.52 kW

COP Tj = Tbiv

2.72

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.52 kW

10.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.68 kW

2.67 kW

Annual energy consumption Qhe

6979 kWh

7890 kWh

Platinum BC Mural Hybrid 12ET iR32
Configure model
Model name
Platinum BC Mural Hybrid 12ET iR32
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.00 kW

El input

2.44 kW

3.87 kW

COP

4.95

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

10.55 kW

10.77 kW

Cooling capacity

4.19

2.92

EER

2.52

3.69

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.55 kW

10.77 kW

SEER

4.09

6.66

Pdc Tj = 35°C

10.55 kW

10.77 kW

EER Tj = 35°C

2.52

3.69

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

7.78 kW

7.88 kW

EER Tj = 30°C

3.58

5.39

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.17 kW

5.20 kW

EER Tj = 25°C

4.57

7.93

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.24 kW

3.03 kW

EER Tj = 20°C

5.05

9.28

Cdc Tj = 20 °C

0.900

0.900

Poff

20 W

20 W

PTO

10 W

10 W

PSB

20 W

20 W

PCK

0 W

0 W

Annual energy consumption Qce

1548 kWh

971 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

135 %

Prated

12.00 kW

11.58 kW

SCOP

4.52

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.61 kW

10.25 kW

COP Tj = -7°C

2.88

2.01

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.48 kW

6.52 kW

COP Tj = +2°C

4.30

3.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.44 kW

4.36 kW

COP Tj = +7°C

6.00

4.59

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.74 kW

3.30 kW

COP Tj = 12°C

8.47

6.05

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.61 kW

10.25 kW

COP Tj = Tbiv

2.88

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.75 kW

9.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.26 kW

2.50 kW

Annual energy consumption Qhe

5482 kWh

6919 kWh

Platinum BC Mural Hybrid 16ET iR32
Configure model
Model name
Platinum BC Mural Hybrid 16ET iR32
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.56 kW

5.52 kW

COP

4.50

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

12.36 kW

11.63 kW

Cooling capacity

5.44

3.22

EER

2.27

3.61

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.36 kW

11.63 kW

SEER

4.23

6.19

Pdc Tj = 35°C

12.36 kW

11.63 kW

EER Tj = 35°C

2.27

3.61

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

9.40 kW

8.67 kW

EER Tj = 30°C

3.41

5.22

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.89 kW

5.39 kW

EER Tj = 25°C

4.89

7.78

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.81 kW

2.48 kW

EER Tj = 20°C

5.80

6.89

Cdc Tj = 20 °C

0.900

0.900

Poff

20 W

20 W

PTO

10 W

10 W

PSB

20 W

20 W

PCK

0 W

0 W

Annual energy consumption Qce

1754 kWh

1128 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

133 %

Prated

15.21 kW

13.02 kW

SCOP

4.50

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.45 kW

11.52 kW

COP Tj = -7°C

2.72

1.99

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.20 kW

7.18 kW

COP Tj = +2°C

4.30

3.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.70 kW

4.56 kW

COP Tj = +7°C

6.20

4.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.78 kW

3.32 kW

COP Tj = 12°C

8.51

6.07

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.45 kW

11.52 kW

COP Tj = Tbiv

2.72

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.52 kW

10.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.68 kW

2.67 kW

Annual energy consumption Qhe

6979 kWh

7890 kWh