3,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.56 kW
10.64 kW
El input
2.19 kW
3.62 kW
COP
4.83
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
3.47 kW
Cooling capacity
11.2
EER
3.22
EN 14825
+7°C/+12°C
Pdesignc
11 kW
SEER
5.92
Pdc Tj = 35°C
11 kW
EER Tj = 35°C
3.19
Pdc Tj = 30°C
8.1 kW
EER Tj = 30°C
4.94
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
5.7 kW
EER Tj = 25°C
7.18
Cdc Tj = 25 °C
0.97
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.47
Cdc Tj = 20 °C
0.97
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1116 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44.7 dB(A)
44.7 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
126 %
Prated
10 kW
10 kW
SCOP
4.63
3.23
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.2 kW
7.9 kW
COP Tj = -7°C
3.03
1.89
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
5.5 kW
5.4 kW
COP Tj = +2°C
4.37
3.25
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.6 kW
4.4 kW
COP Tj = +7°C
6.74
4.81
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.4 kW
5.3 kW
COP Tj = 12°C
8.54
6.41
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
9.2 kW
8.2 kW
COP Tj = Tbiv
3.01
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.4 kW
6.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
1.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.6 kW
3.2 kW
Annual energy consumption Qhe
4462 kWh
6397 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
126 %
COP
3.05
Heating up time
2:34 h:min
Standby power input
36.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.56 kW
10.64 kW
El input
2.19 kW
3.62 kW
COP
4.83
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
3.47 kW
Cooling capacity
11.2
EER
3.22
EN 14825
+7°C/+12°C
Pdesignc
11 kW
SEER
5.92
Pdc Tj = 35°C
11 kW
EER Tj = 35°C
3.19
Pdc Tj = 30°C
8.1 kW
EER Tj = 30°C
4.94
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
5.7 kW
EER Tj = 25°C
7.18
Cdc Tj = 25 °C
0.97
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.47
Cdc Tj = 20 °C
0.97
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1116 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44.7 dB(A)
44.7 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
128 %
Prated
10 kW
10 kW
SCOP
4.72
3.27
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.2 kW
7.9 kW
COP Tj = -7°C
3.03
1.89
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
5.5 kW
5.4 kW
COP Tj = +2°C
4.37
3.25
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.6 kW
4.4 kW
COP Tj = +7°C
6.74
4.81
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.4 kW
5.3 kW
COP Tj = 12°C
8.54
6.41
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
9.2 kW
8.2 kW
COP Tj = Tbiv
3.01
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.4 kW
6.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
1.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.6 kW
3.2 kW
Annual energy consumption Qhe
4378 kWh
6312 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
126 %
COP
3.05
Heating up time
2:34 h:min
Standby power input
36.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.56 kW
10.64 kW
El input
2.19 kW
3.62 kW
COP
4.83
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
3.47 kW
Cooling capacity
11.2
EER
3.22
EN 14825
+7°C/+12°C
Pdesignc
11 kW
SEER
5.92
Pdc Tj = 35°C
11 kW
EER Tj = 35°C
3.19
Pdc Tj = 30°C
8.1 kW
EER Tj = 30°C
4.94
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
5.7 kW
EER Tj = 25°C
7.18
Cdc Tj = 25 °C
0.97
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.47
Cdc Tj = 20 °C
0.97
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1116 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44.7 dB(A)
44.7 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
126 %
Prated
10 kW
10 kW
SCOP
4.63
3.23
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.2 kW
7.9 kW
COP Tj = -7°C
3.03
1.89
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
5.5 kW
5.4 kW
COP Tj = +2°C
4.37
3.25
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.6 kW
4.4 kW
COP Tj = +7°C
6.74
4.81
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.4 kW
5.3 kW
COP Tj = 12°C
8.54
6.41
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
9.2 kW
8.2 kW
COP Tj = Tbiv
3.01
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.4 kW
6.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
1.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.6 kW
3.2 kW
Annual energy consumption Qhe
4462 kWh
6397 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
128 %
COP
3.1
Heating up time
2:34 h:min
Standby power input
31.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.56 kW
10.64 kW
El input
2.19 kW
3.62 kW
COP
4.83
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
3.47 kW
Cooling capacity
11.2
EER
3.22
EN 14825
+7°C/+12°C
Pdesignc
11 kW
SEER
5.92
Pdc Tj = 35°C
11 kW
EER Tj = 35°C
3.19
Pdc Tj = 30°C
8.1 kW
EER Tj = 30°C
4.94
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
5.7 kW
EER Tj = 25°C
7.18
Cdc Tj = 25 °C
0.97
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.47
Cdc Tj = 20 °C
0.97
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1116 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44.7 dB(A)
44.7 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
128 %
Prated
10 kW
10 kW
SCOP
4.72
3.27
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.2 kW
7.9 kW
COP Tj = -7°C
3.03
1.89
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
5.5 kW
5.4 kW
COP Tj = +2°C
4.37
3.25
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.6 kW
4.4 kW
COP Tj = +7°C
6.74
4.81
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.4 kW
5.3 kW
COP Tj = 12°C
8.54
6.41
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
9.2 kW
8.2 kW
COP Tj = Tbiv
3.01
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.4 kW
6.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
1.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.6 kW
3.2 kW
Annual energy consumption Qhe
4378 kWh
6312 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
128 %
COP
3.1
Heating up time
2:34 h:min
Standby power input
31.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
11.87 kW
El input
2.46 kW
4.11 kW
COP
4.87
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.34 kW
Cooling capacity
12.9
EER
2.98
EN 14825
+7°C/+12°C
Pdesignc
12.9 kW
SEER
5.86
Pdc Tj = 35°C
12.9 kW
EER Tj = 35°C
2.96
Pdc Tj = 30°C
8.8 kW
EER Tj = 30°C
4.77
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
6.2 kW
EER Tj = 25°C
7
Cdc Tj = 25 °C
0.97
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.88
Cdc Tj = 20 °C
0.96
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1314 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
126 %
Prated
11 kW
11 kW
SCOP
4.6
3.22
Tbiv
-7 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.8 kW
8.5 kW
COP Tj = -7°C
2.99
1.8
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
6.1 kW
6.2 kW
COP Tj = +2°C
4.35
3.28
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.6 kW
4.4 kW
COP Tj = +7°C
6.7
4.88
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.4 kW
5.3 kW
COP Tj = 12°C
8.65
6.58
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
9.8 kW
8.9 kW
COP Tj = Tbiv
2.99
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.1 kW
7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.71
1.76
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.9 kW
4 kW
Annual energy consumption Qhe
4935 kWh
7047 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
126 %
COP
3.05
Heating up time
2:34 h:min
Standby power input
36.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
11.87 kW
El input
2.46 kW
4.11 kW
COP
4.87
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.34 kW
Cooling capacity
12.9
EER
2.98
EN 14825
+7°C/+12°C
Pdesignc
12.9 kW
SEER
5.86
Pdc Tj = 35°C
12.9 kW
EER Tj = 35°C
2.96
Pdc Tj = 30°C
8.8 kW
EER Tj = 30°C
4.77
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
6.2 kW
EER Tj = 25°C
7
Cdc Tj = 25 °C
0.97
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.88
Cdc Tj = 20 °C
0.96
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1314 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
128 %
Prated
11 kW
11 kW
SCOP
4.68
3.26
Tbiv
-7 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.8 kW
8.5 kW
COP Tj = -7°C
2.99
1.8
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
6.1 kW
6.2 kW
COP Tj = +2°C
4.35
3.28
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.6 kW
4.4 kW
COP Tj = +7°C
6.7
4.88
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.4 kW
5.3 kW
COP Tj = 12°C
8.65
6.58
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
9.8 kW
8.9 kW
COP Tj = Tbiv
2.99
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.1 kW
7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.71
1.76
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.9 kW
4 kW
Annual energy consumption Qhe
4851 kWh
6962 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
126 %
COP
3.05
Heating up time
2:34 h:min
Standby power input
36.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
11.87 kW
El input
2.46 kW
4.11 kW
COP
4.87
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.34 kW
Cooling capacity
12.9
EER
2.98
EN 14825
+7°C/+12°C
Pdesignc
12.9 kW
SEER
5.86
Pdc Tj = 35°C
12.9 kW
EER Tj = 35°C
2.96
Pdc Tj = 30°C
8.8 kW
EER Tj = 30°C
4.77
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
6.2 kW
EER Tj = 25°C
7
Cdc Tj = 25 °C
0.97
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.88
Cdc Tj = 20 °C
0.96
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1314 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
126 %
Prated
11 kW
11 kW
SCOP
4.6
3.22
Tbiv
-7 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.8 kW
8.5 kW
COP Tj = -7°C
2.99
1.8
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
6.1 kW
6.2 kW
COP Tj = +2°C
4.35
3.28
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.6 kW
4.4 kW
COP Tj = +7°C
6.7
4.88
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.4 kW
5.3 kW
COP Tj = 12°C
8.65
6.58
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
9.8 kW
8.9 kW
COP Tj = Tbiv
2.99
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.1 kW
7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.71
1.76
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.9 kW
4 kW
Annual energy consumption Qhe
4935 kWh
7047 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
128 %
COP
3.1
Heating up time
2:34 h:min
Standby power input
31.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
11.87 kW
El input
2.46 kW
4.11 kW
COP
4.87
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.34 kW
Cooling capacity
12.9
EER
2.98
EN 14825
+7°C/+12°C
Pdesignc
12.9 kW
SEER
5.86
Pdc Tj = 35°C
12.9 kW
EER Tj = 35°C
2.96
Pdc Tj = 30°C
8.8 kW
EER Tj = 30°C
4.77
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
6.2 kW
EER Tj = 25°C
7
Cdc Tj = 25 °C
0.97
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.88
Cdc Tj = 20 °C
0.96
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1314 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
128 %
Prated
11 kW
11 kW
SCOP
4.68
3.26
Tbiv
-7 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.8 kW
8.5 kW
COP Tj = -7°C
2.99
1.8
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
6.1 kW
6.2 kW
COP Tj = +2°C
4.35
3.28
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.6 kW
4.4 kW
COP Tj = +7°C
6.7
4.88
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.4 kW
5.3 kW
COP Tj = 12°C
8.65
6.58
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
9.8 kW
8.9 kW
COP Tj = Tbiv
2.99
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.1 kW
7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.71
1.76
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.9 kW
4 kW
Annual energy consumption Qhe
4851 kWh
6962 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
128 %
COP
3.1
Heating up time
2:34 h:min
Standby power input
31.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16 kW
15.63 kW
El input
3.53 kW
5.68 kW
COP
4.53
2.75
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.68 kW
Cooling capacity
13.6
EER
2.91
EN 14825
+7°C/+12°C
Pdesignc
13.6 kW
SEER
5.76
Pdc Tj = 35°C
13.6 kW
EER Tj = 35°C
2.88
Pdc Tj = 30°C
9.7 kW
EER Tj = 30°C
4.58
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
6.2 kW
EER Tj = 25°C
6.99
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.69
Cdc Tj = 20 °C
0.97
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1417 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
130 %
Prated
12 kW
12 kW
SCOP
4.61
3.32
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.2 kW
9.4 kW
COP Tj = -7°C
2.87
1.95
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
6.7 kW
6.9 kW
COP Tj = +2°C
4.33
3.27
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.7 kW
4.4 kW
COP Tj = +7°C
6.83
4.93
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.5 kW
5.3 kW
COP Tj = 12°C
8.82
6.6
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
11.4 kW
10.1 kW
COP Tj = Tbiv
2.72
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.5
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.4 kW
6.1 kW
Annual energy consumption Qhe
5377 kWh
7477 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
126 %
COP
3.05
Heating up time
2:34 h:min
Standby power input
36.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16 kW
15.63 kW
El input
3.53 kW
5.68 kW
COP
4.53
2.75
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.68 kW
Cooling capacity
13.6
EER
2.91
EN 14825
+7°C/+12°C
Pdesignc
13.6 kW
SEER
5.76
Pdc Tj = 35°C
13.6 kW
EER Tj = 35°C
2.88
Pdc Tj = 30°C
9.7 kW
EER Tj = 30°C
4.58
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
6.2 kW
EER Tj = 25°C
6.99
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.69
Cdc Tj = 20 °C
0.97
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1417 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
131 %
Prated
12 kW
12 kW
SCOP
4.68
3.35
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.2 kW
9.4 kW
COP Tj = -7°C
2.87
1.95
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
6.7 kW
6.9 kW
COP Tj = +2°C
4.33
3.27
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.7 kW
4.4 kW
COP Tj = +7°C
6.83
4.93
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.5 kW
5.3 kW
COP Tj = 12°C
8.82
6.6
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
11.4 kW
10.1 kW
COP Tj = Tbiv
2.72
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.5
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.4 kW
6.1 kW
Annual energy consumption Qhe
5293 kWh
7392 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
126 %
COP
3.05
Heating up time
2:34 h:min
Standby power input
36.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16 kW
15.63 kW
El input
3.53 kW
5.68 kW
COP
4.53
2.75
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.68 kW
Cooling capacity
13.6
EER
2.91
EN 14825
+7°C/+12°C
Pdesignc
13.6 kW
SEER
5.76
Pdc Tj = 35°C
13.6 kW
EER Tj = 35°C
2.88
Pdc Tj = 30°C
9.7 kW
EER Tj = 30°C
4.58
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
6.2 kW
EER Tj = 25°C
6.99
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.69
Cdc Tj = 20 °C
0.97
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1417 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
130 %
Prated
12 kW
12 kW
SCOP
4.61
3.32
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.2 kW
9.4 kW
COP Tj = -7°C
2.87
1.95
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
6.7 kW
6.9 kW
COP Tj = +2°C
4.33
3.27
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.7 kW
4.4 kW
COP Tj = +7°C
6.83
4.93
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.5 kW
5.3 kW
COP Tj = 12°C
8.82
6.6
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
11.4 kW
10.1 kW
COP Tj = Tbiv
2.72
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.5
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.4 kW
6.1 kW
Annual energy consumption Qhe
5377 kWh
7477 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
126 %
COP
3.05
Heating up time
2:34 h:min
Standby power input
36.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16 kW
15.63 kW
El input
3.53 kW
5.68 kW
COP
4.53
2.75
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.68 kW
Cooling capacity
13.6
EER
2.91
EN 14825
+7°C/+12°C
Pdesignc
13.6 kW
SEER
5.76
Pdc Tj = 35°C
13.6 kW
EER Tj = 35°C
2.88
Pdc Tj = 30°C
9.7 kW
EER Tj = 30°C
4.58
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
6.2 kW
EER Tj = 25°C
6.99
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.69
Cdc Tj = 20 °C
0.97
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1417 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
131 %
Prated
12 kW
12 kW
SCOP
4.68
3.35
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.2 kW
9.4 kW
COP Tj = -7°C
2.87
1.95
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
6.7 kW
6.9 kW
COP Tj = +2°C
4.33
3.27
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.7 kW
4.4 kW
COP Tj = +7°C
6.83
4.93
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.5 kW
5.3 kW
COP Tj = 12°C
8.82
6.6
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
11.4 kW
10.1 kW
COP Tj = Tbiv
2.72
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.5
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.4 kW
6.1 kW
Annual energy consumption Qhe
5293 kWh
7392 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
126 %
COP
3.05
Heating up time
2:34 h:min
Standby power input
36.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16 kW
15.63 kW
El input
3.53 kW
5.68 kW
COP
4.53
2.75
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.68 kW
Cooling capacity
13.6
EER
2.91
EN 14825
+7°C/+12°C
Pdesignc
13.6 kW
SEER
5.76
Pdc Tj = 35°C
13.6 kW
EER Tj = 35°C
2.88
Pdc Tj = 30°C
9.7 kW
EER Tj = 30°C
4.58
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
6.2 kW
EER Tj = 25°C
6.99
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.69
Cdc Tj = 20 °C
0.97
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1417 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
130 %
Prated
12 kW
12 kW
SCOP
4.61
3.32
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.2 kW
9.4 kW
COP Tj = -7°C
2.87
1.95
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
6.7 kW
6.9 kW
COP Tj = +2°C
4.33
3.27
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.7 kW
4.4 kW
COP Tj = +7°C
6.83
4.93
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.5 kW
5.3 kW
COP Tj = 12°C
8.82
6.6
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
11.4 kW
10.1 kW
COP Tj = Tbiv
2.72
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.5
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.4 kW
6.1 kW
Annual energy consumption Qhe
5377 kWh
7477 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
128 %
COP
3.1
Heating up time
2:34 h:min
Standby power input
31.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16 kW
15.63 kW
El input
3.53 kW
5.68 kW
COP
4.53
2.75
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.68 kW
Cooling capacity
13.6
EER
2.91
EN 14825
+7°C/+12°C
Pdesignc
13.6 kW
SEER
5.76
Pdc Tj = 35°C
13.6 kW
EER Tj = 35°C
2.88
Pdc Tj = 30°C
9.7 kW
EER Tj = 30°C
4.58
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
6.2 kW
EER Tj = 25°C
6.99
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.69
Cdc Tj = 20 °C
0.97
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1417 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
131 %
Prated
12 kW
12 kW
SCOP
4.68
3.35
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.2 kW
9.4 kW
COP Tj = -7°C
2.87
1.95
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
6.7 kW
6.9 kW
COP Tj = +2°C
4.33
3.27
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.7 kW
4.4 kW
COP Tj = +7°C
6.83
4.93
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.5 kW
5.3 kW
COP Tj = 12°C
8.82
6.6
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
11.4 kW
10.1 kW
COP Tj = Tbiv
2.72
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.5
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.4 kW
6.1 kW
Annual energy consumption Qhe
5293 kWh
7392 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
128 %
COP
3.1
Heating up time
2:34 h:min
Standby power input
31.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16 kW
15.63 kW
El input
3.53 kW
5.68 kW
COP
4.53
2.75
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.68 kW
Cooling capacity
13.6
EER
2.91
EN 14825
+7°C/+12°C
Pdesignc
13.6 kW
SEER
5.76
Pdc Tj = 35°C
13.6 kW
EER Tj = 35°C
2.88
Pdc Tj = 30°C
9.7 kW
EER Tj = 30°C
4.58
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
6.2 kW
EER Tj = 25°C
6.99
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.69
Cdc Tj = 20 °C
0.97
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1417 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
130 %
Prated
12 kW
12 kW
SCOP
4.61
3.32
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.2 kW
9.4 kW
COP Tj = -7°C
2.87
1.95
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
6.7 kW
6.9 kW
COP Tj = +2°C
4.33
3.27
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.7 kW
4.4 kW
COP Tj = +7°C
6.83
4.93
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.5 kW
5.3 kW
COP Tj = 12°C
8.82
6.6
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
11.4 kW
10.1 kW
COP Tj = Tbiv
2.72
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.5
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.4 kW
6.1 kW
Annual energy consumption Qhe
5377 kWh
7477 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
128 %
COP
3.1
Heating up time
2:34 h:min
Standby power input
31.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16 kW
15.63 kW
El input
3.53 kW
5.68 kW
COP
4.53
2.75
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.68 kW
Cooling capacity
13.6
EER
2.91
EN 14825
+7°C/+12°C
Pdesignc
13.6 kW
SEER
5.76
Pdc Tj = 35°C
13.6 kW
EER Tj = 35°C
2.88
Pdc Tj = 30°C
9.7 kW
EER Tj = 30°C
4.58
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
6.2 kW
EER Tj = 25°C
6.99
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
5.9 kW
EER Tj = 20°C
8.69
Cdc Tj = 20 °C
0.97
Poff
23 W
PTO
23 W
PSB
23 W
PCK
0 W
Annual energy consumption Qce
1417 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
131 %
Prated
12 kW
12 kW
SCOP
4.68
3.35
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.2 kW
9.4 kW
COP Tj = -7°C
2.87
1.95
Cdh Tj = -7 °C
n/a
1
Pdh Tj = +2°C
6.7 kW
6.9 kW
COP Tj = +2°C
4.33
3.27
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
4.7 kW
4.4 kW
COP Tj = +7°C
6.83
4.93
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.5 kW
5.3 kW
COP Tj = 12°C
8.82
6.6
Cdh Tj = +12 °C
1
1
Pdh Tj = Tbiv
11.4 kW
10.1 kW
COP Tj = Tbiv
2.72
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.5
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
35 °C
55 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.4 kW
6.1 kW
Annual energy consumption Qhe
5293 kWh
7392 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
128 %
COP
3.1
Heating up time
2:34 h:min
Standby power input
31.4 W
Reference hot water temperature
44.1 °C
Mixed water at 40°C
242 l