2,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.87 kW
9.15 kW
El input
2.27 kW
3.26 kW
COP
4.34
2.81
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
133 %
Prated
11 kW
11 kW
SCOP
4.73
3.51
Tbiv
-7 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.9 kW
9.24 kW
COP Tj = -7°C
4.46
2.98
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
9.96 kW
9.45 kW
COP Tj = +2°C
4.72
3.49
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
10.01 kW
9.58 kW
COP Tj = +7°C
4.97
3.89
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
10.07 kW
9.72 kW
COP Tj = 12°C
5.23
4.35
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
9.9 kW
9.29 kW
COP Tj = Tbiv
4.46
3.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.87 kW
9.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.34
2.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
62 °C
62 °C
Poff
6 W
6 W
PTO
6 W
6 W
PSB
6 W
6 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.13 kW
1.85 kW
Annual energy consumption Qhe
4809 kWh
6469 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
83 %
COP
2.03
Heating up time
1:02 h:min
Standby power input
25.4 W
Reference hot water temperature
44.6 °C
Mixed water at 40°C
179 l