2,300 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.50 kW
2.96 kW
El input
0.69 kW
1.05 kW
COP
5.11
2.82
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
2.80 kW
2.33 kW
ηs
231 %
144 %
Prated
2.80 kW
2.33 kW
SCOP
5.86
3.67
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
2.80 kW
2.33 kW
COP Tj = +2°C
4.12
2.30
Pdh Tj = +7°C
1.77 kW
1.56 kW
COP Tj = +7°C
5.53
2.99
Pdh Tj = 12°C
1.61 kW
1.61 kW
COP Tj = 12°C
7.73
5.65
Pdh Tj = Tbiv
2.80 kW
2.33 kW
COP Tj = Tbiv
4.12
2.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.80 kW
2.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.12
2.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
640 kWh
848 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
7.65 kW
7.35 kW
ηs
148 %
117 %
Prated
7.65 kW
7.35 kW
SCOP
3.77
2.99
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.63 kW
4.45 kW
COP Tj = -7°C
3.59
2.79
Pdh Tj = +2°C
2.85 kW
2.82 kW
COP Tj = +2°C
4.97
3.71
Pdh Tj = +7°C
1.76 kW
1.73 kW
COP Tj = +7°C
6.63
5.30
Pdh Tj = 12°C
1.62 kW
1.61 kW
COP Tj = 12°C
8.44
6.71
Pdh Tj = Tbiv
4.63 kW
4.45 kW
COP Tj = Tbiv
3.59
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.92 kW
2.47 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
4.00 kW
Annual energy consumption Qhe
5001 kWh
6057 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.20 kW
4.78 kW
ηs
191 %
135 %
Prated
5.20 kW
4.78 kW
SCOP
4.85
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.23 kW
COP Tj = -7°C
3.34
2.35
Pdh Tj = +2°C
2.79 kW
2.76 kW
COP Tj = +2°C
4.69
3.37
Pdh Tj = +7°C
1.84 kW
1.72 kW
COP Tj = +7°C
6.28
4.26
Pdh Tj = 12°C
1.62 kW
1.58 kW
COP Tj = 12°C
8.44
6.19
Pdh Tj = Tbiv
4.60 kW
4.23 kW
COP Tj = Tbiv
3.34
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.15 kW
3.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.01
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.05 kW
1.04 kW
Annual energy consumption Qhe
2215 kWh
2866 kWh
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.50 kW
2.96 kW
El input
0.69 kW
1.05 kW
COP
5.11
2.82
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
2.80 kW
2.33 kW
ηs
231 %
144 %
Prated
2.80 kW
2.33 kW
SCOP
5.86
3.67
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
2.80 kW
2.33 kW
COP Tj = +2°C
4.12
2.30
Pdh Tj = +7°C
1.77 kW
1.56 kW
COP Tj = +7°C
5.53
2.99
Pdh Tj = 12°C
1.61 kW
1.61 kW
COP Tj = 12°C
7.73
5.65
Pdh Tj = Tbiv
2.80 kW
2.33 kW
COP Tj = Tbiv
4.12
2.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.80 kW
2.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.12
2.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
640 kWh
848 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
7.65 kW
7.35 kW
ηs
148 %
117 %
Prated
7.65 kW
7.35 kW
SCOP
3.77
2.99
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.63 kW
4.45 kW
COP Tj = -7°C
3.59
2.79
Pdh Tj = +2°C
2.85 kW
2.82 kW
COP Tj = +2°C
4.97
3.71
Pdh Tj = +7°C
1.76 kW
1.73 kW
COP Tj = +7°C
6.63
5.30
Pdh Tj = 12°C
1.62 kW
1.61 kW
COP Tj = 12°C
8.44
6.71
Pdh Tj = Tbiv
4.63 kW
4.45 kW
COP Tj = Tbiv
3.59
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.92 kW
2.47 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
4.00 kW
Annual energy consumption Qhe
5001 kWh
6057 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.20 kW
4.78 kW
ηs
191 %
135 %
Prated
5.20 kW
4.78 kW
SCOP
4.85
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.23 kW
COP Tj = -7°C
3.34
2.35
Pdh Tj = +2°C
2.79 kW
2.76 kW
COP Tj = +2°C
4.69
3.37
Pdh Tj = +7°C
1.84 kW
1.72 kW
COP Tj = +7°C
6.28
4.26
Pdh Tj = 12°C
1.62 kW
1.58 kW
COP Tj = 12°C
8.44
6.19
Pdh Tj = Tbiv
4.60 kW
4.23 kW
COP Tj = Tbiv
3.34
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.15 kW
3.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.01
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.05 kW
1.04 kW
Annual energy consumption Qhe
2215 kWh
2866 kWh
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.50 kW
2.96 kW
El input
0.69 kW
1.05 kW
COP
5.11
2.82
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
2.80 kW
2.33 kW
ηs
231 %
144 %
Prated
2.80 kW
2.33 kW
SCOP
5.86
3.67
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
2.80 kW
2.33 kW
COP Tj = +2°C
4.12
2.30
Pdh Tj = +7°C
1.77 kW
1.56 kW
COP Tj = +7°C
5.53
2.99
Pdh Tj = 12°C
1.61 kW
1.61 kW
COP Tj = 12°C
7.73
5.65
Pdh Tj = Tbiv
2.80 kW
2.33 kW
COP Tj = Tbiv
4.12
2.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.80 kW
2.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.12
2.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
640 kWh
848 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
7.65 kW
7.35 kW
ηs
148 %
117 %
Prated
7.65 kW
7.35 kW
SCOP
3.77
2.99
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.63 kW
4.45 kW
COP Tj = -7°C
3.59
2.79
Pdh Tj = +2°C
2.85 kW
2.82 kW
COP Tj = +2°C
4.97
3.71
Pdh Tj = +7°C
1.76 kW
1.73 kW
COP Tj = +7°C
6.63
5.30
Pdh Tj = 12°C
1.62 kW
1.61 kW
COP Tj = 12°C
8.44
6.71
Pdh Tj = Tbiv
4.63 kW
4.45 kW
COP Tj = Tbiv
3.59
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.92 kW
2.47 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
4.00 kW
Annual energy consumption Qhe
5001 kWh
6057 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.20 kW
4.78 kW
ηs
191 %
135 %
Prated
5.20 kW
4.78 kW
SCOP
4.85
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.23 kW
COP Tj = -7°C
3.34
2.35
Pdh Tj = +2°C
2.79 kW
2.76 kW
COP Tj = +2°C
4.69
3.37
Pdh Tj = +7°C
1.84 kW
1.72 kW
COP Tj = +7°C
6.28
4.26
Pdh Tj = 12°C
1.62 kW
1.58 kW
COP Tj = 12°C
8.44
6.19
Pdh Tj = Tbiv
4.60 kW
4.23 kW
COP Tj = Tbiv
3.34
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.15 kW
3.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.01
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.05 kW
1.04 kW
Annual energy consumption Qhe
2215 kWh
2866 kWh
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.50 kW
2.96 kW
El input
0.69 kW
1.05 kW
COP
5.11
2.82
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
2.80 kW
2.33 kW
ηs
231 %
144 %
Prated
2.80 kW
2.33 kW
SCOP
5.86
3.67
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
2.80 kW
2.33 kW
COP Tj = +2°C
4.12
2.30
Pdh Tj = +7°C
1.77 kW
1.56 kW
COP Tj = +7°C
5.53
2.99
Pdh Tj = 12°C
1.61 kW
1.61 kW
COP Tj = 12°C
7.73
5.65
Pdh Tj = Tbiv
2.80 kW
2.33 kW
COP Tj = Tbiv
4.12
2.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.80 kW
2.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.12
2.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
640 kWh
848 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
7.65 kW
7.35 kW
ηs
148 %
117 %
Prated
7.65 kW
7.35 kW
SCOP
3.77
2.99
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.63 kW
4.45 kW
COP Tj = -7°C
3.59
2.79
Pdh Tj = +2°C
2.85 kW
2.82 kW
COP Tj = +2°C
4.97
3.71
Pdh Tj = +7°C
1.76 kW
1.73 kW
COP Tj = +7°C
6.63
5.30
Pdh Tj = 12°C
1.62 kW
1.61 kW
COP Tj = 12°C
8.44
6.71
Pdh Tj = Tbiv
4.63 kW
4.45 kW
COP Tj = Tbiv
3.59
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.92 kW
2.47 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
4.00 kW
Annual energy consumption Qhe
5001 kWh
6057 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.20 kW
4.78 kW
ηs
191 %
135 %
Prated
5.20 kW
4.78 kW
SCOP
4.85
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.23 kW
COP Tj = -7°C
3.34
2.35
Pdh Tj = +2°C
2.79 kW
2.76 kW
COP Tj = +2°C
4.69
3.37
Pdh Tj = +7°C
1.84 kW
1.72 kW
COP Tj = +7°C
6.28
4.26
Pdh Tj = 12°C
1.62 kW
1.58 kW
COP Tj = 12°C
8.44
6.19
Pdh Tj = Tbiv
4.60 kW
4.23 kW
COP Tj = Tbiv
3.34
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.15 kW
3.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.01
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.05 kW
1.04 kW
Annual energy consumption Qhe
2215 kWh
2866 kWh
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.50 kW
2.96 kW
El input
0.69 kW
1.05 kW
COP
5.11
2.82
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
2.80 kW
2.33 kW
ηs
231 %
144 %
Prated
2.80 kW
2.33 kW
SCOP
5.86
3.67
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
2.80 kW
2.33 kW
COP Tj = +2°C
4.12
2.30
Pdh Tj = +7°C
1.77 kW
1.56 kW
COP Tj = +7°C
5.53
2.99
Pdh Tj = 12°C
1.61 kW
1.61 kW
COP Tj = 12°C
7.73
5.65
Pdh Tj = Tbiv
2.80 kW
2.33 kW
COP Tj = Tbiv
4.12
2.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.80 kW
2.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.12
2.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
640 kWh
848 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
7.65 kW
7.35 kW
ηs
148 %
117 %
Prated
7.65 kW
7.35 kW
SCOP
3.77
2.99
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.63 kW
4.45 kW
COP Tj = -7°C
3.59
2.79
Pdh Tj = +2°C
2.85 kW
2.82 kW
COP Tj = +2°C
4.97
3.71
Pdh Tj = +7°C
1.76 kW
1.73 kW
COP Tj = +7°C
6.63
5.30
Pdh Tj = 12°C
1.62 kW
1.61 kW
COP Tj = 12°C
8.44
6.71
Pdh Tj = Tbiv
4.63 kW
4.45 kW
COP Tj = Tbiv
3.59
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.92 kW
2.47 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
4.00 kW
Annual energy consumption Qhe
5001 kWh
6057 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.20 kW
4.78 kW
ηs
191 %
135 %
Prated
5.20 kW
4.78 kW
SCOP
4.85
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.23 kW
COP Tj = -7°C
3.34
2.35
Pdh Tj = +2°C
2.79 kW
2.76 kW
COP Tj = +2°C
4.69
3.37
Pdh Tj = +7°C
1.84 kW
1.72 kW
COP Tj = +7°C
6.28
4.26
Pdh Tj = 12°C
1.62 kW
1.58 kW
COP Tj = 12°C
8.44
6.19
Pdh Tj = Tbiv
4.60 kW
4.23 kW
COP Tj = Tbiv
3.34
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.15 kW
3.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.01
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.05 kW
1.04 kW
Annual energy consumption Qhe
2215 kWh
2866 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.20
Heating up time
02:46 h:min
Standby power input
39.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
240 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
95 %
COP
2.30
Heating up time
02:55 h:min
Standby power input
42.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
242 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
107 %
COP
2.60
Heating up time
01:48 h:min
Standby power input
44.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
241 l
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.50 kW
2.96 kW
El input
0.69 kW
1.05 kW
COP
5.11
2.82
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
2.80 kW
2.33 kW
ηs
231 %
144 %
Prated
2.80 kW
2.33 kW
SCOP
5.86
3.67
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
2.80 kW
2.33 kW
COP Tj = +2°C
4.12
2.30
Pdh Tj = +7°C
1.77 kW
1.56 kW
COP Tj = +7°C
5.53
2.99
Pdh Tj = 12°C
1.61 kW
1.61 kW
COP Tj = 12°C
7.73
5.65
Pdh Tj = Tbiv
2.80 kW
2.33 kW
COP Tj = Tbiv
4.12
2.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.80 kW
2.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.12
2.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
640 kWh
848 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
7.65 kW
7.35 kW
ηs
148 %
117 %
Prated
7.65 kW
7.35 kW
SCOP
3.77
2.99
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.63 kW
4.45 kW
COP Tj = -7°C
3.59
2.79
Pdh Tj = +2°C
2.85 kW
2.82 kW
COP Tj = +2°C
4.97
3.71
Pdh Tj = +7°C
1.76 kW
1.73 kW
COP Tj = +7°C
6.63
5.30
Pdh Tj = 12°C
1.62 kW
1.61 kW
COP Tj = 12°C
8.44
6.71
Pdh Tj = Tbiv
4.63 kW
4.45 kW
COP Tj = Tbiv
3.59
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.92 kW
2.47 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
4.00 kW
Annual energy consumption Qhe
5001 kWh
6057 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.20 kW
4.78 kW
ηs
191 %
135 %
Prated
5.20 kW
4.78 kW
SCOP
4.85
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.23 kW
COP Tj = -7°C
3.34
2.35
Pdh Tj = +2°C
2.79 kW
2.76 kW
COP Tj = +2°C
4.69
3.37
Pdh Tj = +7°C
1.84 kW
1.72 kW
COP Tj = +7°C
6.28
4.26
Pdh Tj = 12°C
1.62 kW
1.58 kW
COP Tj = 12°C
8.44
6.19
Pdh Tj = Tbiv
4.60 kW
4.23 kW
COP Tj = Tbiv
3.34
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.15 kW
3.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.01
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.05 kW
1.04 kW
Annual energy consumption Qhe
2215 kWh
2866 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.20
Heating up time
02:46 h:min
Standby power input
39.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
240 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
95 %
COP
2.30
Heating up time
02:55 h:min
Standby power input
42.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
242 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
107 %
COP
2.60
Heating up time
01:48 h:min
Standby power input
44.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
241 l
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.50 kW
2.96 kW
El input
0.69 kW
1.05 kW
COP
5.11
2.82
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
2.80 kW
2.33 kW
ηs
231 %
144 %
Prated
2.80 kW
2.33 kW
SCOP
5.86
3.67
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
2.80 kW
2.33 kW
COP Tj = +2°C
4.12
2.30
Pdh Tj = +7°C
1.77 kW
1.56 kW
COP Tj = +7°C
5.53
2.99
Pdh Tj = 12°C
1.61 kW
1.61 kW
COP Tj = 12°C
7.73
5.65
Pdh Tj = Tbiv
2.80 kW
2.33 kW
COP Tj = Tbiv
4.12
2.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.80 kW
2.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.12
2.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
640 kWh
848 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
7.65 kW
7.35 kW
ηs
148 %
117 %
Prated
7.65 kW
7.35 kW
SCOP
3.77
2.99
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.63 kW
4.45 kW
COP Tj = -7°C
3.59
2.79
Pdh Tj = +2°C
2.85 kW
2.82 kW
COP Tj = +2°C
4.97
3.71
Pdh Tj = +7°C
1.76 kW
1.73 kW
COP Tj = +7°C
6.63
5.30
Pdh Tj = 12°C
1.62 kW
1.61 kW
COP Tj = 12°C
8.44
6.71
Pdh Tj = Tbiv
4.63 kW
4.45 kW
COP Tj = Tbiv
3.59
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.92 kW
2.47 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
4.00 kW
Annual energy consumption Qhe
5001 kWh
6057 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.20 kW
4.78 kW
ηs
191 %
135 %
Prated
5.20 kW
4.78 kW
SCOP
4.85
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.23 kW
COP Tj = -7°C
3.34
2.35
Pdh Tj = +2°C
2.79 kW
2.76 kW
COP Tj = +2°C
4.69
3.37
Pdh Tj = +7°C
1.84 kW
1.72 kW
COP Tj = +7°C
6.28
4.26
Pdh Tj = 12°C
1.62 kW
1.58 kW
COP Tj = 12°C
8.44
6.19
Pdh Tj = Tbiv
4.60 kW
4.23 kW
COP Tj = Tbiv
3.34
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.15 kW
3.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.01
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.05 kW
1.04 kW
Annual energy consumption Qhe
2215 kWh
2866 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.20
Heating up time
02:46 h:min
Standby power input
39.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
240 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
95 %
COP
2.30
Heating up time
02:55 h:min
Standby power input
42.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
242 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
107 %
COP
2.60
Heating up time
01:48 h:min
Standby power input
44.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
241 l
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.50 kW
2.96 kW
El input
0.69 kW
1.05 kW
COP
5.11
2.82
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
2.80 kW
2.33 kW
ηs
231 %
144 %
Prated
2.80 kW
2.33 kW
SCOP
5.86
3.67
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
2.80 kW
2.33 kW
COP Tj = +2°C
4.12
2.30
Pdh Tj = +7°C
1.77 kW
1.56 kW
COP Tj = +7°C
5.53
2.99
Pdh Tj = 12°C
1.61 kW
1.61 kW
COP Tj = 12°C
7.73
5.65
Pdh Tj = Tbiv
2.80 kW
2.33 kW
COP Tj = Tbiv
4.12
2.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.80 kW
2.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.12
2.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
640 kWh
848 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
7.65 kW
7.35 kW
ηs
148 %
117 %
Prated
7.65 kW
7.35 kW
SCOP
3.77
2.99
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.63 kW
4.45 kW
COP Tj = -7°C
3.59
2.79
Pdh Tj = +2°C
2.85 kW
2.82 kW
COP Tj = +2°C
4.97
3.71
Pdh Tj = +7°C
1.76 kW
1.73 kW
COP Tj = +7°C
6.63
5.30
Pdh Tj = 12°C
1.62 kW
1.61 kW
COP Tj = 12°C
8.44
6.71
Pdh Tj = Tbiv
4.63 kW
4.45 kW
COP Tj = Tbiv
3.59
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.92 kW
2.47 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
4.00 kW
Annual energy consumption Qhe
5001 kWh
6057 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.20 kW
4.78 kW
ηs
191 %
135 %
Prated
5.20 kW
4.78 kW
SCOP
4.85
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.23 kW
COP Tj = -7°C
3.34
2.35
Pdh Tj = +2°C
2.79 kW
2.76 kW
COP Tj = +2°C
4.69
3.37
Pdh Tj = +7°C
1.84 kW
1.72 kW
COP Tj = +7°C
6.28
4.26
Pdh Tj = 12°C
1.62 kW
1.58 kW
COP Tj = 12°C
8.44
6.19
Pdh Tj = Tbiv
4.60 kW
4.23 kW
COP Tj = Tbiv
3.34
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.15 kW
3.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.01
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.05 kW
1.04 kW
Annual energy consumption Qhe
2215 kWh
2866 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.20
Heating up time
02:46 h:min
Standby power input
39.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
240 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
95 %
COP
2.30
Heating up time
02:55 h:min
Standby power input
42.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
242 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
107 %
COP
2.60
Heating up time
01:48 h:min
Standby power input
44.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
241 l
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.50 kW
2.96 kW
El input
0.69 kW
1.05 kW
COP
5.11
2.82
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
2.80 kW
2.33 kW
ηs
231 %
144 %
Prated
2.80 kW
2.33 kW
SCOP
5.86
3.67
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
2.80 kW
2.33 kW
COP Tj = +2°C
4.12
2.30
Pdh Tj = +7°C
1.77 kW
1.56 kW
COP Tj = +7°C
5.53
2.99
Pdh Tj = 12°C
1.61 kW
1.61 kW
COP Tj = 12°C
7.73
5.65
Pdh Tj = Tbiv
2.80 kW
2.33 kW
COP Tj = Tbiv
4.12
2.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.80 kW
2.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.12
2.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
640 kWh
848 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
7.65 kW
7.35 kW
ηs
148 %
117 %
Prated
7.65 kW
7.35 kW
SCOP
3.77
2.99
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.63 kW
4.45 kW
COP Tj = -7°C
3.59
2.79
Pdh Tj = +2°C
2.85 kW
2.82 kW
COP Tj = +2°C
4.97
3.71
Pdh Tj = +7°C
1.76 kW
1.73 kW
COP Tj = +7°C
6.63
5.30
Pdh Tj = 12°C
1.62 kW
1.61 kW
COP Tj = 12°C
8.44
6.71
Pdh Tj = Tbiv
4.63 kW
4.45 kW
COP Tj = Tbiv
3.59
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.92 kW
2.47 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
4.00 kW
Annual energy consumption Qhe
5001 kWh
6057 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.20 kW
4.78 kW
ηs
191 %
135 %
Prated
5.20 kW
4.78 kW
SCOP
4.85
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.23 kW
COP Tj = -7°C
3.34
2.35
Pdh Tj = +2°C
2.79 kW
2.76 kW
COP Tj = +2°C
4.69
3.37
Pdh Tj = +7°C
1.84 kW
1.72 kW
COP Tj = +7°C
6.28
4.26
Pdh Tj = 12°C
1.62 kW
1.58 kW
COP Tj = 12°C
8.44
6.19
Pdh Tj = Tbiv
4.60 kW
4.23 kW
COP Tj = Tbiv
3.34
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.15 kW
3.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.01
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.05 kW
1.04 kW
Annual energy consumption Qhe
2215 kWh
2866 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.20
Heating up time
02:46 h:min
Standby power input
39.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
240 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
95 %
COP
2.30
Heating up time
02:55 h:min
Standby power input
42.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
242 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
107 %
COP
2.60
Heating up time
01:48 h:min
Standby power input
44.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
241 l
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.50 kW
2.96 kW
El input
0.69 kW
1.05 kW
COP
5.11
2.82
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.20 kW
4.78 kW
ηs
191 %
135 %
Prated
5.20 kW
4.78 kW
SCOP
4.85
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.23 kW
COP Tj = -7°C
3.34
2.35
Pdh Tj = +2°C
2.79 kW
2.76 kW
COP Tj = +2°C
4.69
3.37
Pdh Tj = +7°C
1.84 kW
1.72 kW
COP Tj = +7°C
6.28
4.26
Pdh Tj = 12°C
1.62 kW
1.58 kW
COP Tj = 12°C
8.44
6.19
Pdh Tj = Tbiv
4.60 kW
4.23 kW
COP Tj = Tbiv
3.34
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.15 kW
3.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.01
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.05 kW
1.04 kW
Annual energy consumption Qhe
2215 kWh
2866 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
131 %
COP
3.10
Heating up time
01:34 h:min
Standby power input
38.0 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
250 l
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.50 kW
2.96 kW
El input
0.69 kW
1.05 kW
COP
5.11
2.82
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.20 kW
4.78 kW
ηs
191 %
135 %
Prated
5.20 kW
4.78 kW
SCOP
4.85
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.23 kW
COP Tj = -7°C
3.34
2.35
Pdh Tj = +2°C
2.79 kW
2.76 kW
COP Tj = +2°C
4.69
3.37
Pdh Tj = +7°C
1.84 kW
1.72 kW
COP Tj = +7°C
6.28
4.26
Pdh Tj = 12°C
1.62 kW
1.58 kW
COP Tj = 12°C
8.44
6.19
Pdh Tj = Tbiv
4.60 kW
4.23 kW
COP Tj = Tbiv
3.34
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.15 kW
3.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.01
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
11 W
11 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.05 kW
1.04 kW
Annual energy consumption Qhe
2215 kWh
2866 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
131 %
COP
3.10
Heating up time
01:34 h:min
Standby power input
38.0 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
250 l