0,950 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
4.80 kW
El input
0.93 kW
1.48 kW
COP
5.40
3.25
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
192 %
137 %
Prated
5.00 kW
5.00 kW
SCOP
4.88
3.50
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.80 kW
4.30 kW
COP Tj = -7°C
3.43
2.47
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.10 kW
2.70 kW
COP Tj = +2°C
4.83
3.19
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
1.90 kW
1.70 kW
COP Tj = +7°C
5.95
4.89
Cdh Tj = +7 °C
0.950
0.950
Pdh Tj = 12°C
1.70 kW
1.60 kW
COP Tj = 12°C
8.49
6.61
Cdh Tj = +12 °C
0.940
0.940
Pdh Tj = Tbiv
4.80 kW
4.30 kW
COP Tj = Tbiv
3.43
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.40 kW
3.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.46
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
1.40 kW
Annual energy consumption Qhe
2306 kWh
2882 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
239 %
170 %
Prated
5.00 kW
5.00 kW
SCOP
6.05
4.33
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.10 kW
5.20 kW
COP Tj = +2°C
3.85
2.44
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.40 kW
3.20 kW
COP Tj = +7°C
5.80
3.67
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
1.50 kW
1.50 kW
COP Tj = 12°C
7.20
5.79
Cdh Tj = +12 °C
0.950
0.950
Pdh Tj = Tbiv
5.10 kW
5.20 kW
COP Tj = Tbiv
3.85
2.44
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.10 kW
5.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.44
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1124 kWh
1604 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
168 %
112 %
Prated
5.00 kW
4.00 kW
SCOP
4.28
2.88
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.90 kW
2.60 kW
COP Tj = -7°C
3.43
2.05
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
1.80 kW
1.60 kW
COP Tj = +2°C
5.41
3.77
Cdh Tj = +2 °C
0.970
0.970
Pdh Tj = +7°C
1.30 kW
1.30 kW
COP Tj = +7°C
6.24
5.15
Cdh Tj = +7 °C
0.950
0.950
Pdh Tj = 12°C
1.50 kW
1.50 kW
COP Tj = 12°C
8.38
7.21
Cdh Tj = +12 °C
0.950
0.950
Pdh Tj = Tbiv
3.70 kW
3.50 kW
COP Tj = Tbiv
2.85
1.76
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.20 kW
2.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.65
1.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.80 kW
1.50 kW
Annual energy consumption Qhe
2630 kWh
3721 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.70
3.50
COP Tj = -15°C (if TOL<-20°C)
2.85
1.76
Cdh Tj = -15 °C
0.980
0.990
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
XL
Efficiency ηDHW
128 %
128 %
COP
3.06
3.06
Heating up time
4h33min h:min
4:33 h:min
Standby power input
48.3 W
48.3 W
Reference hot water temperature
49.0 °C
49.0 °C
Mixed water at 40°C
333 l
333 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
120 %
COP
3.34
Heating up time
4:9 h:min
Standby power input
30.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
326 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
90 %
COP
2.16
Heating up time
6:36 h:min
Standby power input
62.8 W
Reference hot water temperature
48.0 °C
Mixed water at 40°C
321 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.00 kW
5.80 kW
El input
1.11 kW
1.84 kW
COP
5.41
3.15
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
137 %
Prated
6.00 kW
5.00 kW
SCOP
5.05
3.50
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.10 kW
4.30 kW
COP Tj = -7°C
3.22
2.47
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.40 kW
2.70 kW
COP Tj = +2°C
4.86
3.19
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.00 kW
1.70 kW
COP Tj = +7°C
7.09
4.89
Cdh Tj = +7 °C
0.950
0.950
Pdh Tj = 12°C
1.70 kW
1.60 kW
COP Tj = 12°C
8.49
6.61
Cdh Tj = +12 °C
0.940
0.940
Pdh Tj = Tbiv
5.10 kW
4.30 kW
COP Tj = Tbiv
3.22
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.40 kW
3.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.46
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.40 kW
Annual energy consumption Qhe
2386 kWh
2882 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
239 %
183 %
Prated
5.00 kW
6.00 kW
SCOP
6.05
4.65
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.10 kW
6.00 kW
COP Tj = +2°C
3.85
2.50
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.40 kW
3.90 kW
COP Tj = +7°C
5.80
4.00
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
1.50 kW
1.70 kW
COP Tj = 12°C
7.20
6.13
Cdh Tj = +12 °C
0.950
0.950
Pdh Tj = Tbiv
5.10 kW
6.00 kW
COP Tj = Tbiv
3.85
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.10 kW
6.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1124 kWh
1722 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
164 %
120 %
Prated
5.00 kW
5.00 kW
SCOP
4.18
3.08
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.20 kW
3.30 kW
COP Tj = -7°C
3.47
2.55
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
1.90 kW
1.80 kW
COP Tj = +2°C
5.18
3.67
Cdh Tj = +2 °C
0.970
0.970
Pdh Tj = +7°C
1.30 kW
1.30 kW
COP Tj = +7°C
6.24
5.15
Cdh Tj = +7 °C
0.950
0.950
Pdh Tj = 12°C
1.50 kW
1.50 kW
COP Tj = 12°C
8.38
7.21
Cdh Tj = +12 °C
0.950
0.950
Pdh Tj = Tbiv
3.90 kW
4.00 kW
COP Tj = Tbiv
2.77
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.20 kW
2.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.65
1.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.80 kW
2.50 kW
Annual energy consumption Qhe
2825 kWh
3976 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.90
4.00
COP Tj = -15°C (if TOL<-20°C)
2.77
1.91
Cdh Tj = -15 °C
0.980
0.990
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
XL
Efficiency ηDHW
128 %
128 %
COP
3.06
3.06
Heating up time
4h33min h:min
4:33 h:min
Standby power input
48.3 W
48.3 W
Reference hot water temperature
49.0 °C
49.0 °C
Mixed water at 40°C
333 l
333 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
120 %
COP
3.34
Heating up time
4:9 h:min
Standby power input
30.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
326 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
90 %
COP
2.16
Heating up time
6:36 h:min
Standby power input
62.8 W
Reference hot water temperature
48.0 °C
Mixed water at 40°C
321 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
4.80 kW
El input
0.93 kW
1.48 kW
COP
5.40
3.25
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
192 %
137 %
Prated
5.00 kW
5.00 kW
SCOP
4.88
3.50
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.80 kW
4.30 kW
COP Tj = -7°C
3.43
2.47
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.10 kW
2.70 kW
COP Tj = +2°C
4.83
3.19
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
1.90 kW
1.70 kW
COP Tj = +7°C
5.95
4.89
Cdh Tj = +7 °C
0.950
0.950
Pdh Tj = 12°C
1.70 kW
1.60 kW
COP Tj = 12°C
8.49
6.61
Cdh Tj = +12 °C
0.940
0.940
Pdh Tj = Tbiv
4.80 kW
4.30 kW
COP Tj = Tbiv
3.43
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.40 kW
3.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.46
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
1.40 kW
Annual energy consumption Qhe
2306 kWh
2882 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
239 %
170 %
Prated
5.00 kW
5.00 kW
SCOP
6.05
4.33
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.10 kW
5.20 kW
COP Tj = +2°C
3.85
2.44
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.40 kW
3.20 kW
COP Tj = +7°C
5.80
3.67
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
1.50 kW
1.50 kW
COP Tj = 12°C
7.20
5.79
Cdh Tj = +12 °C
0.950
0.950
Pdh Tj = Tbiv
5.10 kW
5.20 kW
COP Tj = Tbiv
3.85
2.44
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.10 kW
5.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.44
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1124 kWh
1604 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
168 %
112 %
Prated
5.00 kW
4.00 kW
SCOP
4.28
2.88
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.90 kW
2.60 kW
COP Tj = -7°C
3.43
2.05
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
1.80 kW
1.60 kW
COP Tj = +2°C
5.41
3.77
Cdh Tj = +2 °C
0.970
0.970
Pdh Tj = +7°C
1.30 kW
1.30 kW
COP Tj = +7°C
6.24
5.15
Cdh Tj = +7 °C
0.950
0.950
Pdh Tj = 12°C
1.50 kW
1.50 kW
COP Tj = 12°C
8.38
7.21
Cdh Tj = +12 °C
0.950
0.950
Pdh Tj = Tbiv
3.70 kW
3.50 kW
COP Tj = Tbiv
2.85
1.76
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.20 kW
2.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.65
1.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.80 kW
1.50 kW
Annual energy consumption Qhe
2630 kWh
3721 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.70
3.50
COP Tj = -15°C (if TOL<-20°C)
2.85
1.76
Cdh Tj = -15 °C
0.980
0.990
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
XL
Efficiency ηDHW
128 %
128 %
COP
3.06
3.06
Heating up time
4h33min h:min
4:33 h:min
Standby power input
48.3 W
48.3 W
Reference hot water temperature
49.0 °C
49.0 °C
Mixed water at 40°C
333 l
333 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
120 %
COP
3.34
Heating up time
4:9 h:min
Standby power input
30.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
326 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
90 %
COP
2.16
Heating up time
6:36 h:min
Standby power input
62.8 W
Reference hot water temperature
48.0 °C
Mixed water at 40°C
321 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.00 kW
5.80 kW
El input
1.11 kW
1.84 kW
COP
5.41
3.15
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
137 %
Prated
6.00 kW
5.00 kW
SCOP
5.05
3.50
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.10 kW
4.30 kW
COP Tj = -7°C
3.22
2.47
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.40 kW
2.70 kW
COP Tj = +2°C
4.86
3.19
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.00 kW
1.70 kW
COP Tj = +7°C
7.09
4.89
Cdh Tj = +7 °C
0.950
0.950
Pdh Tj = 12°C
1.70 kW
1.60 kW
COP Tj = 12°C
8.49
6.61
Cdh Tj = +12 °C
0.940
0.940
Pdh Tj = Tbiv
5.10 kW
4.30 kW
COP Tj = Tbiv
3.22
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.40 kW
3.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.46
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.40 kW
Annual energy consumption Qhe
2386 kWh
2882 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
239 %
183 %
Prated
5.00 kW
6.00 kW
SCOP
6.05
4.65
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.10 kW
6.00 kW
COP Tj = +2°C
3.85
2.50
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.40 kW
3.90 kW
COP Tj = +7°C
5.80
4.00
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
1.50 kW
1.70 kW
COP Tj = 12°C
7.20
6.13
Cdh Tj = +12 °C
0.950
0.950
Pdh Tj = Tbiv
5.10 kW
6.00 kW
COP Tj = Tbiv
3.85
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.10 kW
6.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1124 kWh
1722 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
164 %
120 %
Prated
5.00 kW
5.00 kW
SCOP
4.18
3.08
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.20 kW
3.30 kW
COP Tj = -7°C
3.47
2.55
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
1.90 kW
1.80 kW
COP Tj = +2°C
5.18
3.67
Cdh Tj = +2 °C
0.970
0.970
Pdh Tj = +7°C
1.30 kW
1.30 kW
COP Tj = +7°C
6.24
5.15
Cdh Tj = +7 °C
0.950
0.950
Pdh Tj = 12°C
1.50 kW
1.50 kW
COP Tj = 12°C
8.38
7.21
Cdh Tj = +12 °C
0.950
0.950
Pdh Tj = Tbiv
3.90 kW
4.00 kW
COP Tj = Tbiv
2.77
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.20 kW
2.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.65
1.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.80 kW
2.50 kW
Annual energy consumption Qhe
2825 kWh
3976 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.90
4.00
COP Tj = -15°C (if TOL<-20°C)
2.77
1.91
Cdh Tj = -15 °C
0.980
0.990
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
XL
Efficiency ηDHW
128 %
128 %
COP
3.06
3.06
Heating up time
4h33min h:min
4:33 h:min
Standby power input
48.3 W
48.3 W
Reference hot water temperature
49.0 °C
49.0 °C
Mixed water at 40°C
333 l
333 l
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
120 %
COP
3.34
Heating up time
4:9 h:min
Standby power input
30.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
326 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
90 %
COP
2.16
Heating up time
6:36 h:min
Standby power input
62.8 W
Reference hot water temperature
48.0 °C
Mixed water at 40°C
321 l