1,050 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.14 kW
8.06 kW
El input
1.64 kW
2.79 kW
COP
4.96
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
134 %
Prated
6.54 kW
5.88 kW
SCOP
4.92
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.76 kW
5.17 kW
COP Tj = -7°C
3.14
1.85
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.52 kW
3.16 kW
COP Tj = +2°C
4.84
3.40
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.32 kW
2.15 kW
COP Tj = +7°C
5.98
4.50
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.98 kW
2.14 kW
COP Tj = 12°C
9.67
7.71
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.76 kW
5.17 kW
COP Tj = Tbiv
3.14
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.66
1.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
11 W
11 W
PSB
10 W
10 W
PCK
1 W
1 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.37 kW
0.20 kW
Annual energy consumption Qhe
2732 kWh
3536 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
137 %
COP
3.36
Heating up time
2:24 h:min
Standby power input
27.0 W
Reference hot water temperature
47.0 °C
Mixed water at 40°C
280 l