1,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.68 kW
7.08 kW
El input
1.73 kW
2.44 kW
COP
4.44
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
148 %
Prated
10.90 kW
9.94 kW
SCOP
5.14
3.90
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.64 kW
8.96 kW
COP Tj = -7°C
4.23
2.98
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.87 kW
5.56 kW
COP Tj = +2°C
5.15
3.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.95 kW
3.78 kW
COP Tj = +7°C
5.85
4.63
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.97 kW
1.90 kW
COP Tj = 12°C
5.85
4.75
Cdh Tj = +12 °C
0.965
0.970
Pdh Tj = Tbiv
10.90 kW
9.94 kW
COP Tj = Tbiv
3.97
2.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.90 kW
9.94 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.97
2.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
kW
kW
Annual energy consumption Qhe
4378 kWh
5267 kWh