2,600 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.95 kW
7.41 kW
El input
1.53 kW
2.35 kW
COP
5.21
3.15
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
243 %
184 %
Prated
6.21 kW
6.05 kW
SCOP
6.16
4.67
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
6.21 kW
6.05 kW
COP Tj = +2°C
4.48
2.72
Cdh Tj = +2 °C
0.987
0.987
Pdh Tj = +7°C
4.15 kW
3.80 kW
COP Tj = +7°C
5.85
4.10
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
4.45 kW
4.60 kW
COP Tj = 12°C
7.20
6.20
Cdh Tj = +12 °C
0.971
0.971
Pdh Tj = Tbiv
6.21 kW
6.05 kW
COP Tj = Tbiv
4.48
2.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.21 kW
6.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.48
2.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
21 W
21 W
PTO
15 W
15 W
PSB
21 W
21 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1347 kWh
1732 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
147 %
127 %
Prated
15.48 kW
15.89 kW
SCOP
3.75
3.24
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
9.37 kW
9.62 kW
COP Tj = -7°C
3.51
2.93
Cdh Tj = -7 °C
0.994
0.994
Pdh Tj = +2°C
5.70 kW
5.87 kW
COP Tj = +2°C
4.85
4.10
Cdh Tj = +2 °C
0.987
0.987
Pdh Tj = +7°C
4.36 kW
4.17 kW
COP Tj = +7°C
6.50
5.85
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
4.41 kW
5.25 kW
COP Tj = 12°C
7.70
6.90
Cdh Tj = +12 °C
0.971
0.971
Pdh Tj = Tbiv
9.37 kW
9.62 kW
COP Tj = Tbiv
3.51
2.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.53 kW
6.53 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.34
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
21 W
21 W
PTO
15 W
15 W
PSB
21 W
21 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
15.48 kW
15.89 kW
Annual energy consumption Qhe
10178 kWh
12133 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.75
7.56
COP Tj = -15°C (if TOL<-20°C)
2.79
1.79
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
156 %
Prated
10.80 kW
10.51 kW
SCOP
4.81
3.96
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
9.73 kW
9.30 kW
COP Tj = -7°C
3.51
2.45
Cdh Tj = -7 °C
0.994
0.994
Pdh Tj = +2°C
5.62 kW
6.12 kW
COP Tj = +2°C
4.79
3.77
Cdh Tj = +2 °C
0.987
0.987
Pdh Tj = +7°C
4.30 kW
3.97 kW
COP Tj = +7°C
6.49
5.70
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
4.41 kW
4.48 kW
COP Tj = 12°C
7.70
6.23
Cdh Tj = +12 °C
0.971
0.971
Pdh Tj = Tbiv
9.73 kW
9.30 kW
COP Tj = Tbiv
3.24
2.45
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.97 kW
8.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.00
2.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
21 W
21 W
PTO
15 W
15 W
PSB
21 W
21 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.83 kW
1.76 kW
Annual energy consumption Qhe
4641 kWh
5480 kWh