Certificate holders

Subtype

AEROTOP SX7

Certificate Holder
ELCO GmbH
Hohenzollernstrasse 31
72379 Hechingen
Germany
Registration number
011-1W0542
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
AEROTOP SX7
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,100 kg

Certification Date
04.08.2022
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 9
Generate PDF Export model CSV
  • Number of models 1

Models

AEROTOP SX7
Configure model
Model name
AEROTOP SX7
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.20 kW

4.60 kW

El input

1.01 kW

1.57 kW

COP

5.17

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

238 %

180 %

Prated

4.97 kW

4.05 kW

SCOP

6.03

4.58

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

4.97 kW

4.05 kW

COP Tj = +2°C

4.41

2.55

Cdh Tj = +2 °C

0.981

0.981

Pdh Tj = +7°C

3.21 kW

2.75 kW

COP Tj = +7°C

5.84

4.00

Cdh Tj = +7 °C

0.958

0.958

Pdh Tj = 12°C

3.25 kW

3.25 kW

COP Tj = 12°C

7.00

6.20

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

4.97 kW

4.04 kW

COP Tj = Tbiv

4.41

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.97 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.41

2.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

21 W

21 W

PTO

15 W

15 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1100 kWh

1180 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

125 %

Prated

11.40 kW

11.10 kW

SCOP

3.97

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

6.90 kW

6.72 kW

COP Tj = -7°C

3.71

2.87

Cdh Tj = -7 °C

0.992

0.992

Pdh Tj = +2°C

4.20 kW

4.06 kW

COP Tj = +2°C

5.45

4.25

Cdh Tj = +2 °C

0.981

0.981

Pdh Tj = +7°C

3.10 kW

3.00 kW

COP Tj = +7°C

6.42

5.85

Cdh Tj = +7 °C

0.958

0.958

Pdh Tj = 12°C

3.32 kW

3.35 kW

COP Tj = 12°C

8.25

6.40

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

6.90 kW

6.72 kW

COP Tj = Tbiv

3.71

2.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.60 kW

4.21 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.989

0.992

WTOL

60 °C

60 °C

Poff

21 W

21 W

PTO

15 W

15 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

11.40 kW

11.20 kW

Annual energy consumption Qhe

7086 kWh

8546 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.60

5.10

COP Tj = -15°C (if TOL<-20°C)

2.90

1.79

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

152 %

Prated

7.82 kW

7.30 kW

SCOP

5.06

3.88

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

6.92 kW

6.46 kW

COP Tj = -7°C

3.40

2.36

Cdh Tj = -7 °C

0.992

0.992

Pdh Tj = +2°C

4.62 kW

4.02 kW

COP Tj = +2°C

5.06

3.70

Cdh Tj = +2 °C

0.981

0.981

Pdh Tj = +7°C

3.15 kW

2.81 kW

COP Tj = +7°C

6.20

5.60

Cdh Tj = +7 °C

0.958

0.958

Pdh Tj = 12°C

3.32 kW

3.24 kW

COP Tj = 12°C

8.25

6.14

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

6.92 kW

6.46 kW

COP Tj = Tbiv

3.40

2.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.40 kW

6.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.11

2.22

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

21 W

21 W

PTO

15 W

15 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.42 kW

1.23 kW

Annual energy consumption Qhe

3192 kWh

3890 kWh