Certificate holders

Subtype

Yutaki M 7.0HP R32 (tri)

Certificate Holder
Johnson Controls-Hitachi AirConditioning Spain
Ronda Shimizu, 1. Pol. Ind. Can Torrella
08233 Vacarisses, Barcelona
Spain
Registration number
041-K002-65
Certification Body
BRE Global Limited
Subtype title
Yutaki M 7.0HP R32 (tri)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

3,000 kg

Certification Date
14.10.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 7

Models

RASM-7R1E - heating only
Configure model
Model name
RASM-7R1E - heating only
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.62 kW

5.84 kW

COP

4.42

2.74

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

125 %

Prated

18.00 kW

18.00 kW

SCOP

3.97

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.00 kW

16.00 kW

COP Tj = -7°C

2.82

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.70 kW

9.70 kW

COP Tj = +2°C

3.88

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.21 kW

6.30 kW

COP Tj = +7°C

5.03

4.12

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.79 kW

4.50 kW

COP Tj = 12°C

5.95

5.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

2.82

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

35 °C

55 °C

Poff

29 W

29 W

PTO

0 W

0 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.10 kW

2.10 kW

Annual energy consumption Qhe

9424 kWh

11651 kWh

RASM-7R1E - with cooling kit
Configure model
Model name
RASM-7R1E - with cooling kit
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.62 kW

5.84 kW

COP

4.42

2.74

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.43 kW

3.26 kW

Cooling capacity

14.00

15.00

EER

3.16

4.60

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

14.00 kW

15.00 kW

SEER

4.08

6.78

Pdc Tj = 35°C

14.00 kW

15.00 kW

EER Tj = 35°C

3.16

4.60

Cdc Tj = 35 °C

 

 

Pdc Tj = 30°C

10.32 kW

11.05 kW

EER Tj = 30°C

3.97

6.03

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

6.62 kW

7.11 kW

EER Tj = 25°C

4.61

7.87

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.19 kW

4.90 kW

EER Tj = 20°C

4.63

10.39

Cdc Tj = 20 °C

0.900

0.900

Poff

29 W

29 W

PTO

0 W

0 W

PSB

29 W

29 W

PCK

0 W

0 W

Annual energy consumption Qce

1201 kWh

774 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

126 %

Prated

18.00 kW

18.00 kW

SCOP

3.97

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.00 kW

16.00 kW

COP Tj = -7°C

2.82

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.70 kW

9.70 kW

COP Tj = +2°C

3.88

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.21 kW

6.30 kW

COP Tj = +7°C

5.03

4.12

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.79 kW

4.50 kW

COP Tj = 12°C

5.95

5.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

2.82

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

35 °C

55 °C

Poff

29 W

29 W

PTO

0 W

0 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.10 kW

2.10 kW

Annual energy consumption Qhe

9318 kWh

11545 kWh

RASM-7RW1E & HWM-WE - heating only
Configure model
Model name
RASM-7RW1E & HWM-WE - heating only
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.62 kW

5.84 kW

COP

4.42

2.74

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

125 %

Prated

18.00 kW

18.00 kW

SCOP

3.97

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.00 kW

16.00 kW

COP Tj = -7°C

2.82

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.70 kW

9.70 kW

COP Tj = +2°C

3.88

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.21 kW

6.30 kW

COP Tj = +7°C

5.03

4.12

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.79 kW

4.50 kW

COP Tj = 12°C

5.95

5.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

2.82

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

35 °C

55 °C

Poff

29 W

29 W

PTO

0 W

0 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.10 kW

2.10 kW

Annual energy consumption Qhe

9424 kWh

11651 kWh

RASM-7RW1E & HWM-WE - with cooling kit
Configure model
Model name
RASM-7RW1E & HWM-WE - with cooling kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.62 kW

5.84 kW

COP

4.42

2.74

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.43 kW

3.26 kW

Cooling capacity

14.00

15.00

EER

3.16

4.60

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

14.00 kW

15.00 kW

SEER

4.08

6.78

Pdc Tj = 35°C

14.00 kW

15.00 kW

EER Tj = 35°C

3.16

4.60

Cdc Tj = 35 °C

 

 

Pdc Tj = 30°C

10.32 kW

11.05 kW

EER Tj = 30°C

3.97

6.03

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

6.62 kW

7.11 kW

EER Tj = 25°C

4.61

7.87

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.19 kW

4.90 kW

EER Tj = 20°C

4.63

10.39

Cdc Tj = 20 °C

0.900

0.900

Poff

29 W

29 W

PTO

0 W

0 W

PSB

29 W

29 W

PCK

0 W

0 W

Annual energy consumption Qce

1201 kWh

774 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

126 %

Prated

18.00 kW

18.00 kW

SCOP

3.97

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.00 kW

16.00 kW

COP Tj = -7°C

2.82

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.70 kW

9.70 kW

COP Tj = +2°C

3.88

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.21 kW

6.30 kW

COP Tj = +7°C

5.03

4.12

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.79 kW

4.50 kW

COP Tj = 12°C

5.95

5.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

2.82

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

35 °C

55 °C

Poff

29 W

29 W

PTO

0 W

0 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.10 kW

2.10 kW

Annual energy consumption Qhe

9318 kWh

11545 kWh

RASM-7RW1E & HWD-WE-220S - heating only
Configure model
Model name
RASM-7RW1E & HWD-WE-220S - heating only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.62 kW

5.84 kW

COP

4.42

2.74

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

125 %

Prated

18.00 kW

18.00 kW

SCOP

3.97

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.00 kW

16.00 kW

COP Tj = -7°C

2.82

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.70 kW

9.70 kW

COP Tj = +2°C

3.88

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.21 kW

6.30 kW

COP Tj = +7°C

5.03

4.12

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.79 kW

4.50 kW

COP Tj = 12°C

5.95

5.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

2.82

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

35 °C

55 °C

Poff

29 W

29 W

PTO

0 W

0 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.10 kW

2.10 kW

Annual energy consumption Qhe

9424 kWh

11651 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

95 %

COP

2.30

Heating up time

1:10 h:min

Standby power input

56.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

288 l

RASM-7RW1E & HWD-WE-220S-K - heating only
Configure model
Model name
RASM-7RW1E & HWD-WE-220S-K - heating only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.62 kW

5.84 kW

COP

4.42

2.74

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

125 %

Prated

18.00 kW

18.00 kW

SCOP

3.97

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.00 kW

16.00 kW

COP Tj = -7°C

2.82

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.70 kW

9.70 kW

COP Tj = +2°C

3.88

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.21 kW

6.30 kW

COP Tj = +7°C

5.03

4.12

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.79 kW

4.50 kW

COP Tj = 12°C

5.95

5.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

2.82

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

35 °C

55 °C

Poff

29 W

29 W

PTO

0 W

0 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.10 kW

2.10 kW

Annual energy consumption Qhe

9424 kWh

11651 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

95 %

COP

2.30

Heating up time

1:10 h:min

Standby power input

56.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

288 l

RASM-7RW1E & HWD-WE-220S - with cooling kit
Configure model
Model name
RASM-7RW1E & HWD-WE-220S - with cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.62 kW

5.84 kW

COP

4.42

2.74

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.43 kW

3.26 kW

Cooling capacity

14.00

15.00

EER

3.16

4.60

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

14.00 kW

15.00 kW

SEER

4.08

6.78

Pdc Tj = 35°C

14.00 kW

15.00 kW

EER Tj = 35°C

3.16

4.60

Cdc Tj = 35 °C

 

 

Pdc Tj = 30°C

10.32 kW

11.05 kW

EER Tj = 30°C

3.97

6.03

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

6.62 kW

7.11 kW

EER Tj = 25°C

4.61

7.87

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.19 kW

4.90 kW

EER Tj = 20°C

4.63

10.39

Cdc Tj = 20 °C

0.900

0.900

Poff

29 W

29 W

PTO

0 W

0 W

PSB

29 W

29 W

PCK

0 W

0 W

Annual energy consumption Qce

1201 kWh

774 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

126 %

Prated

18.00 kW

18.00 kW

SCOP

3.97

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.00 kW

16.00 kW

COP Tj = -7°C

2.82

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.70 kW

9.70 kW

COP Tj = +2°C

3.88

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.21 kW

6.30 kW

COP Tj = +7°C

5.03

4.12

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.79 kW

4.50 kW

COP Tj = 12°C

5.95

5.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

2.82

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

35 °C

55 °C

Poff

29 W

29 W

PTO

0 W

0 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.10 kW

2.10 kW

Annual energy consumption Qhe

9318 kWh

11545 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

95 %

COP

2.30

Heating up time

1:10 h:min

Standby power input

56.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

288 l