Certificate holders

Subtype

HA 8-7.2 OS 230V B3 / HA 10-7.2 OS 230V B3

Certificate Holder
Saunier Duval Brand Group


Germany
Registration number
011-1W0556
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
HA 8-7.2 OS 230V B3 / HA 10-7.2 OS 230V B3
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,600 kg

Certification Date
26.09.2022
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 10 (as of 2022-06)
Generate PDF Export model CSV
  • Number of models 10

Models

HA 10-7.2 OS 230V B3 + HA 10-7.2 WSB
Configure model
Model name
HA 10-7.2 OS 230V B3 + HA 10-7.2 WSB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.85 kW

7.40 kW

El input

2.11 kW

2.32 kW

COP

4.68

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.00 kW

1.90 kW

Cooling capacity

7.32

7.16

EER

2.44

3.76

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.69 kW

8.44 kW

SEER

3.97

5.94

Pdc Tj = 35°C

7.69 kW

8.44 kW

EER Tj = 35°C

2.39

3.61

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.34 kW

5.98 kW

EER Tj = 30°C

3.43

5.01

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.32 kW

4.48 kW

EER Tj = 25°C

4.44

6.84

Cdc Tj = 25 °C

0.975

0.972

Pdc Tj = 20°C

3.65 kW

4.82 kW

EER Tj = 20°C

5.50

8.57

Cdc Tj = 20 °C

0.972

0.967

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1161 kWh

853 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

162 %

Prated

8.03 kW

7.39 kW

SCOP

5.71

4.12

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.03 kW

7.39 kW

COP Tj = +2°C

3.35

2.08

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.51 kW

5.16 kW

COP Tj = +7°C

5.21

3.50

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.41 kW

5.40 kW

COP Tj = 12°C

7.05

5.55

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

8.03 kW

7.39 kW

COP Tj = Tbiv

3.35

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.03 kW

7.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1878 kWh

2396 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

144 %

106 %

Prated

6.86 kW

8.14 kW

SCOP

3.69

2.72

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

4.31 kW

4.73 kW

COP Tj = -7°C

3.00

2.20

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

3.62 kW

3.34 kW

COP Tj = +2°C

4.54

3.48

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

4.44 kW

4.42 kW

COP Tj = +7°C

6.02

5.02

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.08 kW

5.18 kW

COP Tj = 12°C

7.37

5.62

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

5.60 kW

6.64 kW

COP Tj = Tbiv

2.20

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.80 kW

6.64 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.86 kW

8.14 kW

Annual energy consumption Qhe

4587 kWh

7362 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.60

6.64

COP Tj = -15°C (if TOL<-20°C)

2.20

1.72

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

130 %

Prated

7.75 kW

8.35 kW

SCOP

4.51

3.34

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.86 kW

7.38 kW

COP Tj = -7°C

2.80

2.24

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

4.10 kW

4.39 kW

COP Tj = +2°C

4.43

3.10

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.47 kW

4.45 kW

COP Tj = +7°C

6.09

4.51

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.12 kW

5.34 kW

COP Tj = 12°C

7.95

6.07

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

6.86 kW

7.38 kW

COP Tj = Tbiv

2.80

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.08 kW

7.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.67 kW

1.28 kW

Annual energy consumption Qhe

3548 kWh

5170 kWh

HA 10-7.2 OS 230V B3 + HA 10-7.2 WS
Configure model
Model name
HA 10-7.2 OS 230V B3 + HA 10-7.2 WS
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.85 kW

7.40 kW

El input

2.11 kW

2.32 kW

COP

4.68

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.00 kW

1.90 kW

Cooling capacity

7.32

7.16

EER

2.44

3.76

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.69 kW

8.44 kW

SEER

3.97

5.94

Pdc Tj = 35°C

7.69 kW

8.44 kW

EER Tj = 35°C

2.39

3.61

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.34 kW

5.98 kW

EER Tj = 30°C

3.43

5.01

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.32 kW

4.48 kW

EER Tj = 25°C

4.44

6.84

Cdc Tj = 25 °C

1.000

0.972

Pdc Tj = 20°C

3.65 kW

4.82 kW

EER Tj = 20°C

5.50

8.57

Cdc Tj = 20 °C

0.972

0.967

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1161 kWh

853 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

162 %

Prated

8.03 kW

7.39 kW

SCOP

5.71

4.12

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.03 kW

7.39 kW

COP Tj = +2°C

3.35

2.08

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.51 kW

5.16 kW

COP Tj = +7°C

5.21

3.50

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

5.41 kW

5.40 kW

COP Tj = 12°C

7.05

5.55

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

8.03 kW

7.39 kW

COP Tj = Tbiv

3.35

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.03 kW

7.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1878 kWh

2396 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

130 %

Prated

6.08 kW

7.07 kW

SCOP

4.51

3.33

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.86 kW

7.38 kW

COP Tj = -7°C

2.80

2.24

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.10 kW

4.39 kW

COP Tj = +2°C

4.43

3.10

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.47 kW

4.45 kW

COP Tj = +7°C

6.09

4.51

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

5.12 kW

5.34 kW

COP Tj = 12°C

7.95

6.07

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

6.08 kW

7.07 kW

COP Tj = Tbiv

2.40

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.08 kW

7.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2787 kWh

4379 kWh

HA 10-7.2 OS 230V B3 + HA 10-7.2 STB
Configure model
Model name
HA 10-7.2 OS 230V B3 + HA 10-7.2 STB
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.85 kW

7.40 kW

El input

2.11 kW

2.32 kW

COP

4.68

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.00 kW

1.90 kW

Cooling capacity

7.32

7.16

EER

2.44

3.76

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.69 kW

8.44 kW

SEER

3.97

5.94

Pdc Tj = 35°C

7.69 kW

8.44 kW

EER Tj = 35°C

2.39

3.61

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.34 kW

5.98 kW

EER Tj = 30°C

3.43

5.01

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.32 kW

4.48 kW

EER Tj = 25°C

4.44

6.84

Cdc Tj = 25 °C

0.975

0.972

Pdc Tj = 20°C

3.65 kW

4.82 kW

EER Tj = 20°C

5.50

8.57

Cdc Tj = 20 °C

0.972

0.967

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1161 kWh

853 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

162 %

Prated

8.03 kW

7.39 kW

SCOP

5.71

4.12

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.03 kW

7.39 kW

COP Tj = +2°C

3.35

2.08

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.51 kW

5.16 kW

COP Tj = +7°C

5.21

3.50

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.41 kW

5.40 kW

COP Tj = 12°C

7.05

5.55

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

8.03 kW

7.39 kW

COP Tj = Tbiv

3.35

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.03 kW

7.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1878 kWh

2396 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

144 %

106 %

Prated

6.86 kW

8.14 kW

SCOP

3.69

2.72

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

4.31 kW

4.73 kW

COP Tj = -7°C

3.00

2.20

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

3.62 kW

3.34 kW

COP Tj = +2°C

4.54

3.48

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

4.44 kW

4.42 kW

COP Tj = +7°C

6.02

5.02

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.08 kW

5.18 kW

COP Tj = 12°C

7.37

5.62

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

5.60 kW

6.64 kW

COP Tj = Tbiv

2.20

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.80 kW

6.64 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.86 kW

8.14 kW

Annual energy consumption Qhe

4587 kWh

7362 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.60

6.64

COP Tj = -15°C (if TOL<-20°C)

2.20

1.72

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

130 %

Prated

7.75 kW

8.35 kW

SCOP

4.51

3.34

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.86 kW

7.38 kW

COP Tj = -7°C

2.80

2.24

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

4.10 kW

4.39 kW

COP Tj = +2°C

4.43

3.10

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.47 kW

4.45 kW

COP Tj = +7°C

6.09

4.51

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.12 kW

5.34 kW

COP Tj = 12°C

7.95

6.07

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

6.86 kW

7.38 kW

COP Tj = Tbiv

2.80

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.08 kW

7.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.67 kW

1.28 kW

Annual energy consumption Qhe

3548 kWh

5170 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113.9 %

COP

2.72

Heating up time

00:51 h:min

Standby power input

34.9 W

Reference hot water temperature

51.68 °C

Mixed water at 40°C

236.73 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

83 %

COP

2.00

Heating up time

00:57 h:min

Standby power input

40.9 W

Reference hot water temperature

51.45 °C

Mixed water at 40°C

235.28 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

98.5 %

COP

2.36

Heating up time

00:54 h:min

Standby power input

39.0 W

Reference hot water temperature

51.53 °C

Mixed water at 40°C

236.2 l

HA 10-7.2 OS 230V B3 + HA 10-7.2 STB C2
Configure model
Model name
HA 10-7.2 OS 230V B3 + HA 10-7.2 STB C2
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.85 kW

7.40 kW

El input

2.16 kW

2.37 kW

COP

4.57

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.05 kW

1.95 kW

Cooling capacity

7.32

7.16

EER

2.40

3.67

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.69 kW

8.44 kW

SEER

3.78

5.60

Pdc Tj = 35°C

7.69 kW

8.44 kW

EER Tj = 35°C

2.35

3.54

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.34 kW

5.98 kW

EER Tj = 30°C

3.33

4.81

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.32 kW

4.48 kW

EER Tj = 25°C

4.16

6.35

Cdc Tj = 25 °C

1.000

0.974

Pdc Tj = 20°C

3.65 kW

4.82 kW

EER Tj = 20°C

5.11

7.87

Cdc Tj = 20 °C

0.974

0.970

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1220 kWh

904 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

214 %

156 %

Prated

8.03 kW

7.39 kW

SCOP

5.43

3.97

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.03 kW

7.39 kW

COP Tj = +2°C

3.28

2.05

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.51 kW

5.16 kW

COP Tj = +7°C

4.97

3.39

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.41 kW

5.40 kW

COP Tj = 12°C

6.62

5.28

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.03 kW

7.39 kW

COP Tj = Tbiv

3.28

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.03 kW

7.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.28

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1976 kWh

2490 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

138 %

102 %

Prated

6.86 kW

8.14 kW

SCOP

3.52

2.64

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

4.31 kW

4.73 kW

COP Tj = -7°C

2.90

2.15

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

3.62 kW

3.34 kW

COP Tj = +2°C

4.27

3.31

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

4.44 kW

4.42 kW

COP Tj = +7°C

5.64

4.75

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.08 kW

5.18 kW

COP Tj = 12°C

6.87

5.33

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

5.60 kW

6.64 kW

COP Tj = Tbiv

2.16

1.70

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.80 kW

6.64 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.05

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.86 kW

8.14 kW

Annual energy consumption Qhe

4798 kWh

7612 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.60

6.64

COP Tj = -15°C (if TOL<-20°C)

2.16

1.70

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

126 %

Prated

7.75 kW

8.35 kW

SCOP

4.30

3.22

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.86 kW

7.38 kW

COP Tj = -7°C

2.74

2.21

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

4.10 kW

4.39 kW

COP Tj = +2°C

4.20

3.00

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.47 kW

4.45 kW

COP Tj = +7°C

5.70

4.29

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.12 kW

5.34 kW

COP Tj = 12°C

7.37

5.74

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

6.86 kW

7.38 kW

COP Tj = Tbiv

2.74

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.08 kW

7.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.35

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.67 kW

1.28 kW

Annual energy consumption Qhe

3729 kWh

5354 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113.9 %

COP

2.72

Heating up time

00:51 h:min

Standby power input

34.9 W

Reference hot water temperature

51.68 °C

Mixed water at 40°C

236.73 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

83 %

COP

2.00

Heating up time

00:57 h:min

Standby power input

40.9 W

Reference hot water temperature

51.45 °C

Mixed water at 40°C

235.28 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

98.5 %

COP

2.36

Heating up time

00:54 h:min

Standby power input

39.0 W

Reference hot water temperature

51.53 °C

Mixed water at 40°C

236.2 l

HA 10-7.2 OS 230V B3 + HA 10-7.2 STB B5
Configure model
Model name
HA 10-7.2 OS 230V B3 + HA 10-7.2 STB B5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.85 kW

7.40 kW

El input

2.11 kW

2.32 kW

COP

4.68

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.00 kW

1.90 kW

Cooling capacity

7.32

7.16

EER

2.44

3.76

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.69 kW

8.44 kW

SEER

3.97

5.94

Pdc Tj = 35°C

7.69 kW

8.44 kW

EER Tj = 35°C

2.39

3.61

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.34 kW

5.98 kW

EER Tj = 30°C

3.43

5.01

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.32 kW

4.48 kW

EER Tj = 25°C

4.44

6.84

Cdc Tj = 25 °C

0.975

0.972

Pdc Tj = 20°C

3.65 kW

4.82 kW

EER Tj = 20°C

5.50

8.57

Cdc Tj = 20 °C

0.972

0.967

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1161 kWh

853 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

162 %

Prated

8.03 kW

7.39 kW

SCOP

5.71

4.12

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.03 kW

7.39 kW

COP Tj = +2°C

3.35

2.08

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.51 kW

5.16 kW

COP Tj = +7°C

5.21

3.50

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.41 kW

5.40 kW

COP Tj = 12°C

7.05

5.55

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

8.03 kW

7.39 kW

COP Tj = Tbiv

3.35

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.03 kW

7.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1878 kWh

2396 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

144 %

106 %

Prated

6.86 kW

8.14 kW

SCOP

3.69

2.72

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

4.31 kW

4.73 kW

COP Tj = -7°C

3.00

2.20

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

3.62 kW

3.34 kW

COP Tj = +2°C

4.54

3.48

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

4.44 kW

4.42 kW

COP Tj = +7°C

6.02

5.02

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.08 kW

5.18 kW

COP Tj = 12°C

7.37

5.62

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

5.60 kW

6.64 kW

COP Tj = Tbiv

2.20

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.80 kW

6.64 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.86 kW

8.14 kW

Annual energy consumption Qhe

4587 kWh

7362 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.60

6.64

COP Tj = -15°C (if TOL<-20°C)

2.20

1.72

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

130 %

Prated

7.75 kW

8.35 kW

SCOP

4.51

3.34

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.86 kW

7.38 kW

COP Tj = -7°C

2.80

2.24

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

4.10 kW

4.39 kW

COP Tj = +2°C

4.43

3.10

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.47 kW

4.45 kW

COP Tj = +7°C

6.09

4.51

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.12 kW

5.34 kW

COP Tj = 12°C

7.95

6.07

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

6.86 kW

7.38 kW

COP Tj = Tbiv

2.80

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.08 kW

7.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.67 kW

1.28 kW

Annual energy consumption Qhe

3548 kWh

5170 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113.9 %

COP

2.72

Heating up time

00:51 h:min

Standby power input

34.9 W

Reference hot water temperature

51.68 °C

Mixed water at 40°C

236.73 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

83 %

COP

2.00

Heating up time

00:57 h:min

Standby power input

40.9 W

Reference hot water temperature

51.45 °C

Mixed water at 40°C

235.28 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

98.5 %

COP

2.36

Heating up time

00:54 h:min

Standby power input

39.0 W

Reference hot water temperature

51.53 °C

Mixed water at 40°C

236.2 l

HA 8-7.2 OS 230V B3 + HA 10-7.2 WSB
Configure model
Model name
HA 8-7.2 OS 230V B3 + HA 10-7.2 WSB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.88 kW

6.71 kW

El input

1.70 kW

2.14 kW

COP

4.65

3.14

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.27 kW

1.78 kW

Cooling capacity

6.37

7.04

EER

2.81

3.96

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.41 kW

7.04 kW

SEER

4.04

6.00

Pdc Tj = 35°C

7.41 kW

7.04 kW

EER Tj = 35°C

2.54

3.96

Cdc Tj = 35 °C

0.994

1.000

Pdc Tj = 30°C

5.40 kW

5.15 kW

EER Tj = 30°C

3.43

5.24

Cdc Tj = 30 °C

0.988

1.000

Pdc Tj = 25°C

3.45 kW

4.60 kW

EER Tj = 25°C

4.35

6.81

Cdc Tj = 25 °C

0.977

0.973

Pdc Tj = 20°C

4.00 kW

5.00 kW

EER Tj = 20°C

6.05

8.80

Cdc Tj = 20 °C

0.972

0.968

Poff

15 W

15 W

PTO

18 W

18 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1100 kWh

704 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

156 %

Prated

8.03 kW

7.02 kW

SCOP

5.71

3.96

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.03 kW

7.02 kW

COP Tj = +2°C

3.35

2.16

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.51 kW

4.73 kW

COP Tj = +7°C

5.21

3.40

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.41 kW

5.27 kW

COP Tj = 12°C

7.05

5.22

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

8.03 kW

7.02 kW

COP Tj = Tbiv

3.35

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.03 kW

7.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1878 kWh

2367 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

109 %

Prated

7.74 kW

8.13 kW

SCOP

3.71

2.81

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

4.97 kW

4.50 kW

COP Tj = -7°C

3.05

2.31

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

3.38 kW

3.71 kW

COP Tj = +2°C

4.40

3.65

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

4.57 kW

4.37 kW

COP Tj = +7°C

6.37

4.73

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.06 kW

5.02 kW

COP Tj = 12°C

7.71

6.07

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

6.31 kW

6.63 kW

COP Tj = Tbiv

2.50

1.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.25 kW

6.63 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.94

1.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.74 kW

8.13 kW

Annual energy consumption Qhe

5141 kWh

7129 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.31

6.63

COP Tj = -15°C (if TOL<-20°C)

2.50

1.73

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

131 %

Prated

7.46 kW

7.68 kW

SCOP

4.46

3.34

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.60 kW

6.80 kW

COP Tj = -7°C

2.84

2.16

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

3.89 kW

4.12 kW

COP Tj = +2°C

4.46

3.26

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.40 kW

4.31 kW

COP Tj = +7°C

5.72

4.29

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.08 kW

5.16 kW

COP Tj = 12°C

7.39

5.81

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

6.60 kW

6.80 kW

COP Tj = Tbiv

2.84

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.75 kW

6.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.45

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.71 kW

1.18 kW

Annual energy consumption Qhe

3457 kWh

4755 kWh

HA 8-7.2 OS 230V B3 + HA 10-7.2 WS
Configure model
Model name
HA 8-7.2 OS 230V B3 + HA 10-7.2 WS
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.88 kW

6.71 kW

El input

1.70 kW

2.14 kW

COP

4.65

3.14

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.27 kW

1.78 kW

Cooling capacity

6.37

7.04

EER

2.81

3.96

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.41 kW

7.04 kW

SEER

4.04

6.00

Pdc Tj = 35°C

7.41 kW

7.04 kW

EER Tj = 35°C

2.54

3.96

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.40 kW

5.15 kW

EER Tj = 30°C

3.43

5.24

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.45 kW

4.60 kW

EER Tj = 25°C

4.35

6.81

Cdc Tj = 25 °C

1.000

0.973

Pdc Tj = 20°C

4.00 kW

5.00 kW

EER Tj = 20°C

6.05

8.80

Cdc Tj = 20 °C

0.972

0.968

Poff

15 W

15 W

PTO

18 W

18 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1100 kWh

704 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

156 %

Prated

8.03 kW

7.02 kW

SCOP

5.71

3.96

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.03 kW

7.02 kW

COP Tj = +2°C

3.35

2.16

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.51 kW

4.73 kW

COP Tj = +7°C

5.21

3.40

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

5.41 kW

5.27 kW

COP Tj = 12°C

7.05

5.22

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

8.03 kW

7.02 kW

COP Tj = Tbiv

3.35

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.03 kW

7.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1878 kWh

2367 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

130 %

Prated

5.75 kW

6.51 kW

SCOP

4.45

3.33

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.60 kW

6.80 kW

COP Tj = -7°C

2.84

2.16

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.89 kW

4.12 kW

COP Tj = +2°C

4.46

3.26

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

4.40 kW

4.31 kW

COP Tj = +7°C

5.72

4.29

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

5.08 kW

5.16 kW

COP Tj = 12°C

7.39

5.81

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

5.75 kW

6.51 kW

COP Tj = Tbiv

2.45

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.75 kW

6.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.45

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2669 kWh

4032 kWh

HA 8-7.2 OS 230V B3 + HA 10-7.2 STB
Configure model
Model name
HA 8-7.2 OS 230V B3 + HA 10-7.2 STB
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.88 kW

6.71 kW

El input

1.70 kW

2.14 kW

COP

4.65

3.14

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.27 kW

1.78 kW

Cooling capacity

6.37

7.04

EER

2.81

3.96

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.41 kW

7.04 kW

SEER

4.04

6.00

Pdc Tj = 35°C

7.41 kW

7.04 kW

EER Tj = 35°C

2.54

3.96

Cdc Tj = 35 °C

0.994

1.000

Pdc Tj = 30°C

5.40 kW

5.15 kW

EER Tj = 30°C

3.43

5.24

Cdc Tj = 30 °C

0.988

1.000

Pdc Tj = 25°C

3.45 kW

4.60 kW

EER Tj = 25°C

4.35

6.81

Cdc Tj = 25 °C

0.977

0.973

Pdc Tj = 20°C

4.00 kW

5.00 kW

EER Tj = 20°C

6.05

8.80

Cdc Tj = 20 °C

0.972

0.968

Poff

15 W

15 W

PTO

18 W

18 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1100 kWh

704 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

156 %

Prated

8.03 kW

7.02 kW

SCOP

5.71

3.96

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.03 kW

7.02 kW

COP Tj = +2°C

3.35

2.16

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.51 kW

4.73 kW

COP Tj = +7°C

5.21

3.40

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.41 kW

5.27 kW

COP Tj = 12°C

7.05

5.22

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

8.03 kW

7.02 kW

COP Tj = Tbiv

3.35

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.03 kW

7.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1878 kWh

2367 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

109 %

Prated

7.74 kW

8.13 kW

SCOP

3.71

2.81

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

4.97 kW

4.50 kW

COP Tj = -7°C

3.05

2.31

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

3.38 kW

3.71 kW

COP Tj = +2°C

4.40

3.65

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

4.57 kW

4.37 kW

COP Tj = +7°C

6.37

4.73

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.06 kW

5.02 kW

COP Tj = 12°C

7.71

6.07

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

6.31 kW

6.63 kW

COP Tj = Tbiv

2.50

1.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.25 kW

6.63 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.94

1.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.74 kW

8.13 kW

Annual energy consumption Qhe

5141 kWh

7129 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.31

6.63

COP Tj = -15°C (if TOL<-20°C)

2.50

1.73

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

131 %

Prated

7.46 kW

7.68 kW

SCOP

4.46

3.34

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.60 kW

6.80 kW

COP Tj = -7°C

2.84

2.16

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

3.89 kW

4.12 kW

COP Tj = +2°C

4.46

3.26

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.40 kW

4.31 kW

COP Tj = +7°C

5.72

4.29

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.08 kW

5.16 kW

COP Tj = 12°C

7.39

5.81

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

6.60 kW

6.80 kW

COP Tj = Tbiv

2.84

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.75 kW

6.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.45

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.71 kW

1.18 kW

Annual energy consumption Qhe

3457 kWh

4755 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113.9 %

COP

2.72

Heating up time

00:51 h:min

Standby power input

34.9 W

Reference hot water temperature

51.68 °C

Mixed water at 40°C

236.73 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

83 %

COP

2.00

Heating up time

00:57 h:min

Standby power input

40.9 W

Reference hot water temperature

51.45 °C

Mixed water at 40°C

235.28 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

98.5 %

COP

2.36

Heating up time

00:54 h:min

Standby power input

39.0 W

Reference hot water temperature

51.53 °C

Mixed water at 40°C

236.2 l

HA 8-7.2 OS 230V B3 + HA 10-7.2 STB C2
Configure model
Model name
HA 8-7.2 OS 230V B3 + HA 10-7.2 STB C2
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.88 kW

6.71 kW

El input

1.75 kW

2.19 kW

COP

4.51

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.32 kW

1.83 kW

Cooling capacity

6.37

7.04

EER

2.75

3.85

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.41 kW

7.04 kW

SEER

3.85

5.66

Pdc Tj = 35°C

7.41 kW

7.04 kW

EER Tj = 35°C

2.49

3.85

Cdc Tj = 35 °C

0.994

1.000

Pdc Tj = 30°C

5.40 kW

5.15 kW

EER Tj = 30°C

3.33

4.98

Cdc Tj = 30 °C

0.989

1.000

Pdc Tj = 25°C

3.45 kW

4.60 kW

EER Tj = 25°C

4.09

6.34

Cdc Tj = 25 °C

0.978

0.975

Pdc Tj = 20°C

4.00 kW

5.00 kW

EER Tj = 20°C

5.63

8.09

Cdc Tj = 20 °C

0.974

0.970

Poff

15 W

15 W

PTO

18 W

18 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1155 kWh

747 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

214 %

149 %

Prated

8.03 kW

7.02 kW

SCOP

5.43

3.81

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.03 kW

7.02 kW

COP Tj = +2°C

3.28

2.13

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.51 kW

4.73 kW

COP Tj = +7°C

4.97

3.28

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.41 kW

5.27 kW

COP Tj = 12°C

6.62

4.97

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.03 kW

7.02 kW

COP Tj = Tbiv

3.28

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.03 kW

7.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.28

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1976 kWh

2460 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

139 %

106 %

Prated

7.74 kW

8.13 kW

SCOP

3.55

2.72

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

4.97 kW

4.50 kW

COP Tj = -7°C

2.96

2.26

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

3.38 kW

3.71 kW

COP Tj = +2°C

4.13

3.48

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

4.57 kW

4.37 kW

COP Tj = +7°C

5.96

4.49

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.06 kW

5.02 kW

COP Tj = 12°C

7.16

5.72

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

6.31 kW

6.63 kW

COP Tj = Tbiv

2.45

1.70

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.25 kW

6.63 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.90

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.74 kW

8.13 kW

Annual energy consumption Qhe

5375 kWh

7367 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.31

6.63

COP Tj = -15°C (if TOL<-20°C)

2.45

1.70

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

166 %

126 %

Prated

7.46 kW

7.68 kW

SCOP

4.24

3.22

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.60 kW

6.80 kW

COP Tj = -7°C

2.78

2.13

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

3.89 kW

4.12 kW

COP Tj = +2°C

4.22

3.13

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.40 kW

4.31 kW

COP Tj = +7°C

5.37

4.09

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

5.08 kW

5.16 kW

COP Tj = 12°C

6.89

5.50

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

6.60 kW

6.80 kW

COP Tj = Tbiv

2.78

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.75 kW

6.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.71 kW

1.18 kW

Annual energy consumption Qhe

3636 kWh

4934 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113.9 %

COP

2.72

Heating up time

00:51 h:min

Standby power input

34.9 W

Reference hot water temperature

51.68 °C

Mixed water at 40°C

236.73 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

83 %

COP

2.00

Heating up time

00:57 h:min

Standby power input

40.9 W

Reference hot water temperature

51.45 °C

Mixed water at 40°C

235.28 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

98.5 %

COP

2.36

Heating up time

00:54 h:min

Standby power input

39.0 W

Reference hot water temperature

51.53 °C

Mixed water at 40°C

236.2 l

HA 8-7.2 OS 230V B3 + HA 10-7.2 STB B5
Configure model
Model name
HA 8-7.2 OS 230V B3 + HA 10-7.2 STB B5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.88 kW

6.71 kW

El input

1.70 kW

2.14 kW

COP

4.65

3.14

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.27 kW

1.78 kW

Cooling capacity

6.37

7.04

EER

2.81

3.96

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.41 kW

7.04 kW

SEER

4.04

6.00

Pdc Tj = 35°C

7.41 kW

7.04 kW

EER Tj = 35°C

2.54

3.96

Cdc Tj = 35 °C

0.994

1.000

Pdc Tj = 30°C

5.40 kW

5.15 kW

EER Tj = 30°C

3.43

5.24

Cdc Tj = 30 °C

0.988

1.000

Pdc Tj = 25°C

3.45 kW

4.60 kW

EER Tj = 25°C

4.35

6.81

Cdc Tj = 25 °C

0.977

0.973

Pdc Tj = 20°C

4.00 kW

5.00 kW

EER Tj = 20°C

6.05

8.80

Cdc Tj = 20 °C

0.972

0.968

Poff

15 W

15 W

PTO

18 W

18 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1100 kWh

704 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

156 %

Prated

8.03 kW

7.02 kW

SCOP

5.71

3.96

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.03 kW

7.02 kW

COP Tj = +2°C

3.35

2.16

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.51 kW

4.73 kW

COP Tj = +7°C

5.21

3.40

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.41 kW

5.27 kW

COP Tj = 12°C

7.05

5.22

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

8.03 kW

7.02 kW

COP Tj = Tbiv

3.35

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.03 kW

7.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1878 kWh

2367 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

109 %

Prated

7.74 kW

8.13 kW

SCOP

3.71

2.81

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

4.97 kW

4.50 kW

COP Tj = -7°C

3.05

2.31

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

3.38 kW

3.71 kW

COP Tj = +2°C

4.40

3.65

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

4.57 kW

4.37 kW

COP Tj = +7°C

6.37

4.73

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.06 kW

5.02 kW

COP Tj = 12°C

7.71

6.07

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

6.31 kW

6.63 kW

COP Tj = Tbiv

2.50

1.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.25 kW

6.63 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.94

1.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.74 kW

8.13 kW

Annual energy consumption Qhe

5141 kWh

7129 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.31

6.63

COP Tj = -15°C (if TOL<-20°C)

2.50

1.73

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

131 %

Prated

7.46 kW

7.68 kW

SCOP

4.46

3.34

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.60 kW

6.80 kW

COP Tj = -7°C

2.84

2.16

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

3.89 kW

4.12 kW

COP Tj = +2°C

4.46

3.26

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.40 kW

4.31 kW

COP Tj = +7°C

5.72

4.29

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

5.08 kW

5.16 kW

COP Tj = 12°C

7.39

5.81

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

6.60 kW

6.80 kW

COP Tj = Tbiv

2.84

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.75 kW

6.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.45

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.71 kW

1.18 kW

Annual energy consumption Qhe

3457 kWh

4755 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113.9 %

COP

2.72

Heating up time

00:51 h:min

Standby power input

34.9 W

Reference hot water temperature

51.68 °C

Mixed water at 40°C

236.73 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

83 %

COP

2.00

Heating up time

00:57 h:min

Standby power input

40.9 W

Reference hot water temperature

51.45 °C

Mixed water at 40°C

235.28 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

98.5 %

COP

2.36

Heating up time

00:54 h:min

Standby power input

39.0 W

Reference hot water temperature

51.53 °C

Mixed water at 40°C

236.2 l