1,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.21 kW
4.32 kW
El input
0.79 kW
1.48 kW
COP
5.31
2.91
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.21 kW
0.81 kW
Cooling capacity
3.61
4.00
EER
2.97
4.96
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.61 kW
3.84 kW
SEER
4.85
7.34
Pdc Tj = 35°C
3.61 kW
3.84 kW
EER Tj = 35°C
2.97
5.07
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.45 kW
3.18 kW
EER Tj = 30°C
4.08
6.80
Cdc Tj = 30 °C
1.000
0.970
Pdc Tj = 25°C
2.48 kW
3.45 kW
EER Tj = 25°C
5.66
8.94
Cdc Tj = 25 °C
0.967
0.963
Pdc Tj = 20°C
2.85 kW
3.63 kW
EER Tj = 20°C
8.15
11.65
Cdc Tj = 20 °C
0.959
0.954
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Annual energy consumption Qce
446 kWh
314 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
225 %
156 %
Prated
4.42 kW
4.27 kW
SCOP
5.71
3.97
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.42 kW
4.27 kW
COP Tj = +2°C
3.49
2.17
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.57 kW
2.75 kW
COP Tj = +7°C
5.53
3.54
Cdh Tj = +7 °C
1.00
0.99
Pdh Tj = 12°C
2.76 kW
2.61 kW
COP Tj = 12°C
6.45
4.89
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.42 kW
4.27 kW
COP Tj = Tbiv
3.49
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.42 kW
4.27 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.49
2.17
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1033 kWh
1438 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
145 %
102 %
Prated
4.12 kW
3.68 kW
SCOP
3.71
2.63
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.58 kW
2.26 kW
COP Tj = -7°C
2.88
1.97
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
2.20 kW
2.09 kW
COP Tj = +2°C
4.80
3.58
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.74 kW
2.72 kW
COP Tj = +7°C
6.40
4.79
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.80 kW
2.69 kW
COP Tj = 12°C
6.64
5.61
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
3.36 kW
3.00 kW
COP Tj = Tbiv
2.20
1.58
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.72 kW
3.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.74
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.12 kW
3.68 kW
Annual energy consumption Qhe
2742 kWh
3440 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.36
3.00
COP Tj = -15°C (if TOL<-20°C)
2.20
1.58
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
133 %
Prated
4.75 kW
5.09 kW
SCOP
4.62
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.20 kW
4.50 kW
COP Tj = -7°C
3.08
2.19
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
2.66 kW
2.76 kW
COP Tj = +2°C
4.51
3.35
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.72 kW
2.46 kW
COP Tj = +7°C
6.19
4.45
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
3.01 kW
2.65 kW
COP Tj = 12°C
6.46
5.38
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
4.20 kW
4.50 kW
COP Tj = Tbiv
3.08
2.19
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.67 kW
3.37 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.08 kW
1.71 kW
Annual energy consumption Qhe
2126 kWh
3084 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.21 kW
4.32 kW
El input
0.79 kW
1.48 kW
COP
5.31
2.91
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.21 kW
0.81 kW
Cooling capacity
3.61
4.00
EER
2.97
4.96
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.61 kW
3.84 kW
SEER
4.85
7.34
Pdc Tj = 35°C
3.61 kW
3.84 kW
EER Tj = 35°C
2.97
5.07
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.45 kW
3.18 kW
EER Tj = 30°C
4.08
6.80
Cdc Tj = 30 °C
1.000
0.970
Pdc Tj = 25°C
2.48 kW
3.45 kW
EER Tj = 25°C
5.66
8.94
Cdc Tj = 25 °C
0.967
0.963
Pdc Tj = 20°C
2.85 kW
3.63 kW
EER Tj = 20°C
8.15
11.65
Cdc Tj = 20 °C
0.959
0.954
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Annual energy consumption Qce
446 kWh
314 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
225 %
156 %
Prated
4.42 kW
4.39 kW
SCOP
5.71
3.97
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.42 kW
4.39 kW
COP Tj = +2°C
3.49
2.21
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
2.57 kW
2.75 kW
COP Tj = +7°C
5.53
3.54
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
2.76 kW
2.61 kW
COP Tj = 12°C
6.45
4.89
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
4.42 kW
4.39 kW
COP Tj = Tbiv
3.49
2.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.42 kW
4.39 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.49
2.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1033 kWh
1477 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
134 %
Prated
3.67 kW
3.37 kW
SCOP
4.63
3.41
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.20 kW
4.50 kW
COP Tj = -7°C
3.08
2.19
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
2.66 kW
2.76 kW
COP Tj = +2°C
4.51
3.35
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.72 kW
2.46 kW
COP Tj = +7°C
6.19
4.45
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
3.01 kW
2.65 kW
COP Tj = 12°C
6.46
5.38
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
3.67 kW
3.37 kW
COP Tj = Tbiv
2.54
1.60
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.67 kW
3.37 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1635 kWh
2042 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.21 kW
4.32 kW
El input
0.79 kW
1.48 kW
COP
5.31
2.91
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.21 kW
0.81 kW
Cooling capacity
3.61
4.00
EER
2.97
4.96
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.61 kW
3.84 kW
SEER
4.85
7.34
Pdc Tj = 35°C
3.61 kW
3.84 kW
EER Tj = 35°C
2.97
5.07
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.45 kW
3.18 kW
EER Tj = 30°C
4.08
6.80
Cdc Tj = 30 °C
1.000
0.970
Pdc Tj = 25°C
2.48 kW
3.45 kW
EER Tj = 25°C
5.66
8.94
Cdc Tj = 25 °C
0.967
0.963
Pdc Tj = 20°C
2.85 kW
3.63 kW
EER Tj = 20°C
8.15
11.65
Cdc Tj = 20 °C
0.959
0.954
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Annual energy consumption Qce
446 kWh
314 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
225 %
156 %
Prated
4.42 kW
4.27 kW
SCOP
5.71
3.97
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.42 kW
4.27 kW
COP Tj = +2°C
3.49
2.17
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.57 kW
2.75 kW
COP Tj = +7°C
5.53
3.54
Cdh Tj = +7 °C
1.00
0.99
Pdh Tj = 12°C
2.76 kW
2.61 kW
COP Tj = 12°C
6.45
4.89
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.42 kW
4.27 kW
COP Tj = Tbiv
3.49
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.42 kW
4.27 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.49
2.17
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1033 kWh
1438 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
145 %
102 %
Prated
4.12 kW
3.68 kW
SCOP
3.71
2.63
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.58 kW
2.26 kW
COP Tj = -7°C
2.88
1.97
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
2.20 kW
2.09 kW
COP Tj = +2°C
4.80
3.58
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.74 kW
2.72 kW
COP Tj = +7°C
6.40
4.79
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.80 kW
2.69 kW
COP Tj = 12°C
6.64
5.61
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
3.36 kW
3.00 kW
COP Tj = Tbiv
2.20
1.58
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.72 kW
3.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.74
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.12 kW
3.68 kW
Annual energy consumption Qhe
2742 kWh
3440 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.36
3.00
COP Tj = -15°C (if TOL<-20°C)
2.20
1.58
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
133 %
Prated
4.75 kW
5.09 kW
SCOP
4.62
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.20 kW
4.50 kW
COP Tj = -7°C
3.08
2.19
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.66 kW
2.76 kW
COP Tj = +2°C
4.51
3.35
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.72 kW
2.46 kW
COP Tj = +7°C
6.19
4.45
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.01 kW
2.65 kW
COP Tj = 12°C
6.46
5.38
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.20 kW
4.50 kW
COP Tj = Tbiv
3.08
2.19
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.67 kW
3.37 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.08 kW
1.71 kW
Annual energy consumption Qhe
2126 kWh
3084 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
131.3 %
COP
3.14
Heating up time
01:00 h:min
Standby power input
29.1 W
Reference hot water temperature
51.6 °C
Mixed water at 40°C
237.7 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
89.3 %
COP
2.16
Heating up time
01:10 h:min
Standby power input
33.7 W
Reference hot water temperature
51.06 °C
Mixed water at 40°C
233.99 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
110.1 %
COP
2.65
Heating up time
01:05 h:min
Standby power input
31.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
235.37 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.21 kW
4.32 kW
El input
0.84 kW
1.53 kW
COP
5.00
2.82
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.26 kW
0.86 kW
Cooling capacity
3.61
4.00
EER
2.85
4.67
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.61 kW
3.84 kW
SEER
4.44
6.63
Pdc Tj = 35°C
3.61 kW
3.84 kW
EER Tj = 35°C
2.85
4.75
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.45 kW
3.18 kW
EER Tj = 30°C
3.77
6.14
Cdc Tj = 30 °C
1.000
0.972
Pdc Tj = 25°C
2.48 kW
3.45 kW
EER Tj = 25°C
5.08
7.91
Cdc Tj = 25 °C
0.971
0.967
Pdc Tj = 20°C
2.85 kW
3.63 kW
EER Tj = 20°C
7.13
10.04
Cdc Tj = 20 °C
0.964
0.961
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Annual energy consumption Qce
488 kWh
347 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
204 %
145 %
Prated
4.44 kW
4.39 kW
SCOP
5.16
3.70
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.42 kW
4.39 kW
COP Tj = +2°C
3.36
2.16
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.57 kW
2.75 kW
COP Tj = +7°C
4.99
3.33
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
2.76 kW
2.61 kW
COP Tj = 12°C
5.77
4.47
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.44 kW
4.39 kW
COP Tj = Tbiv
3.34
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.44 kW
4.39 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.34
2.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1148 kWh
1586 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
135 %
97 %
Prated
4.12 kW
3.68 kW
SCOP
3.44
2.49
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.58 kW
2.26 kW
COP Tj = -7°C
2.72
1.89
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
2.20 kW
2.09 kW
COP Tj = +2°C
4.33
3.29
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.74 kW
2.72 kW
COP Tj = +7°C
5.73
4.40
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.80 kW
2.69 kW
COP Tj = 12°C
5.93
5.08
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
3.36 kW
3.00 kW
COP Tj = Tbiv
2.13
1.54
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.72 kW
3.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.68
1.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.12 kW
3.68 kW
Annual energy consumption Qhe
2954 kWh
3639 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.36
3.00
COP Tj = -15°C (if TOL<-20°C)
2.13
1.54
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
168 %
125 %
Prated
4.75 kW
5.09 kW
SCOP
4.27
3.21
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.20 kW
4.50 kW
COP Tj = -7°C
2.97
2.14
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.66 kW
2.76 kW
COP Tj = +2°C
4.15
3.16
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.72 kW
2.46 kW
COP Tj = +7°C
5.55
4.08
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.01 kW
2.65 kW
COP Tj = 12°C
5.84
4.89
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.20 kW
4.50 kW
COP Tj = Tbiv
2.97
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.67 kW
3.37 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.45
1.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.08 kW
1.71 kW
Annual energy consumption Qhe
2301 kWh
3276 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
131.3 %
COP
3.14
Heating up time
01:00 h:min
Standby power input
29.1 W
Reference hot water temperature
51.6 °C
Mixed water at 40°C
237.7 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
89.3 %
COP
2.16
Heating up time
01:10 h:min
Standby power input
33.7 W
Reference hot water temperature
51.06 °C
Mixed water at 40°C
233.99 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
110.1 %
COP
2.65
Heating up time
01:05 h:min
Standby power input
31.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
235.37 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.21 kW
4.32 kW
El input
0.79 kW
1.48 kW
COP
5.31
2.91
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.21 kW
0.81 kW
Cooling capacity
3.61
4.00
EER
2.97
4.96
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.61 kW
3.84 kW
SEER
4.85
7.34
Pdc Tj = 35°C
3.61 kW
3.84 kW
EER Tj = 35°C
2.97
5.07
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.45 kW
3.18 kW
EER Tj = 30°C
4.08
6.80
Cdc Tj = 30 °C
1.000
0.970
Pdc Tj = 25°C
2.48 kW
3.45 kW
EER Tj = 25°C
5.66
8.94
Cdc Tj = 25 °C
0.967
0.963
Pdc Tj = 20°C
2.85 kW
3.63 kW
EER Tj = 20°C
8.15
11.65
Cdc Tj = 20 °C
0.959
0.954
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Annual energy consumption Qce
446 kWh
314 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
225 %
156 %
Prated
4.42 kW
4.27 kW
SCOP
5.71
3.97
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.42 kW
4.27 kW
COP Tj = +2°C
3.49
2.17
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.57 kW
2.75 kW
COP Tj = +7°C
5.53
3.54
Cdh Tj = +7 °C
1.00
0.99
Pdh Tj = 12°C
2.76 kW
2.61 kW
COP Tj = 12°C
6.45
4.89
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.42 kW
4.27 kW
COP Tj = Tbiv
3.49
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.42 kW
4.27 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.49
2.17
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1033 kWh
1438 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
145 %
102 %
Prated
4.12 kW
3.68 kW
SCOP
3.71
2.63
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.58 kW
2.26 kW
COP Tj = -7°C
2.88
1.97
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
2.20 kW
2.09 kW
COP Tj = +2°C
4.80
3.58
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.74 kW
2.72 kW
COP Tj = +7°C
6.40
4.79
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.80 kW
2.69 kW
COP Tj = 12°C
6.64
5.61
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
3.36 kW
3.00 kW
COP Tj = Tbiv
2.20
1.58
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.72 kW
3.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.74
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.12 kW
3.68 kW
Annual energy consumption Qhe
2742 kWh
3440 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.36
3.00
COP Tj = -15°C (if TOL<-20°C)
2.20
1.58
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
133 %
Prated
4.75 kW
5.09 kW
SCOP
4.62
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.20 kW
4.50 kW
COP Tj = -7°C
3.08
2.19
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.66 kW
2.76 kW
COP Tj = +2°C
4.51
3.35
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.72 kW
2.46 kW
COP Tj = +7°C
6.19
4.45
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.01 kW
2.65 kW
COP Tj = 12°C
6.46
5.38
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.20 kW
4.50 kW
COP Tj = Tbiv
3.08
2.19
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.67 kW
3.37 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.08 kW
1.71 kW
Annual energy consumption Qhe
2126 kWh
3084 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
131.3 %
COP
3.14
Heating up time
01:00 h:min
Standby power input
29.1 W
Reference hot water temperature
51.6 °C
Mixed water at 40°C
237.7 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
89.3 %
COP
2.16
Heating up time
01:10 h:min
Standby power input
33.7 W
Reference hot water temperature
51.06 °C
Mixed water at 40°C
233.99 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
110.1 %
COP
2.65
Heating up time
01:05 h:min
Standby power input
31.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
235.37 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.07 kW
6.09 kW
El input
1.20 kW
1.85 kW
COP
5.05
3.28
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.79 kW
1.39 kW
Cooling capacity
5.14
5.90
EER
2.87
4.25
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.22 kW
5.71 kW
SEER
4.68
7.24
Pdc Tj = 35°C
5.22 kW
5.71 kW
EER Tj = 35°C
2.81
4.30
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
3.99 kW
4.07 kW
EER Tj = 30°C
3.58
5.93
Cdc Tj = 30 °C
0.987
1.000
Pdc Tj = 25°C
2.35 kW
3.31 kW
EER Tj = 25°C
5.42
8.58
Cdc Tj = 25 °C
0.967
0.963
Pdc Tj = 20°C
2.71 kW
3.58 kW
EER Tj = 20°C
7.71
11.87
Cdc Tj = 20 °C
0.959
0.953
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Annual energy consumption Qce
669 kWh
473 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
230 %
156 %
Prated
4.81 kW
4.57 kW
SCOP
5.83
3.97
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.81 kW
4.57 kW
COP Tj = +2°C
3.30
2.20
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.10 kW
2.75 kW
COP Tj = +7°C
5.63
3.54
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.82 kW
2.61 kW
COP Tj = 12°C
6.65
4.89
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.81 kW
4.57 kW
COP Tj = Tbiv
3.30
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.81 kW
4.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.30
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1102 kWh
1536 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
147 %
101 %
Prated
4.48 kW
3.95 kW
SCOP
3.75
2.61
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.74 kW
2.51 kW
COP Tj = -7°C
2.86
1.97
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
2.26 kW
2.00 kW
COP Tj = +2°C
5.04
3.50
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.68 kW
2.68 kW
COP Tj = +7°C
6.36
4.82
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.83 kW
2.73 kW
COP Tj = 12°C
6.79
5.79
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
3.66 kW
3.22 kW
COP Tj = Tbiv
2.09
1.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.99 kW
3.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.70
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.48 kW
3.95 kW
Annual energy consumption Qhe
2949 kWh
3733 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.66
3.22
COP Tj = -15°C (if TOL<-20°C)
2.09
1.51
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
136 %
Prated
5.01 kW
5.21 kW
SCOP
4.61
3.46
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.43 kW
4.61 kW
COP Tj = -7°C
3.06
2.20
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.81 kW
2.81 kW
COP Tj = +2°C
4.46
3.43
Cdh Tj = +2 °C
0.99
1.00
Pdh Tj = +7°C
2.74 kW
2.42 kW
COP Tj = +7°C
6.25
4.45
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.01 kW
2.68 kW
COP Tj = 12°C
6.44
5.53
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.43 kW
4.61 kW
COP Tj = Tbiv
3.06
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.04 kW
3.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.97 kW
1.22 kW
Annual energy consumption Qhe
2246 kWh
3109 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.07 kW
6.09 kW
El input
1.20 kW
1.85 kW
COP
5.05
3.28
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.79 kW
1.39 kW
Cooling capacity
5.14
5.90
EER
2.87
4.25
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.22 kW
5.71 kW
SEER
4.68
7.24
Pdc Tj = 35°C
5.22 kW
5.71 kW
EER Tj = 35°C
2.81
4.30
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
3.99 kW
4.07 kW
EER Tj = 30°C
3.58
5.93
Cdc Tj = 30 °C
0.987
1.000
Pdc Tj = 25°C
2.35 kW
3.31 kW
EER Tj = 25°C
5.42
8.58
Cdc Tj = 25 °C
0.967
0.963
Pdc Tj = 20°C
2.71 kW
3.58 kW
EER Tj = 20°C
7.71
11.87
Cdc Tj = 20 °C
0.959
0.953
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Annual energy consumption Qce
669 kWh
473 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
230 %
156 %
Prated
4.81 kW
4.57 kW
SCOP
5.83
3.97
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.81 kW
4.57 kW
COP Tj = +2°C
3.30
2.20
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
3.10 kW
2.75 kW
COP Tj = +7°C
5.63
3.54
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
2.82 kW
2.61 kW
COP Tj = 12°C
6.65
4.89
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
4.81 kW
4.57 kW
COP Tj = Tbiv
3.30
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.81 kW
4.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.30
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1102 kWh
1536 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
136 %
Prated
4.04 kW
3.99 kW
SCOP
4.62
3.47
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.43 kW
4.61 kW
COP Tj = -7°C
3.06
2.20
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
2.81 kW
2.81 kW
COP Tj = +2°C
4.46
3.43
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.74 kW
2.42 kW
COP Tj = +7°C
6.25
4.45
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
3.01 kW
2.68 kW
COP Tj = 12°C
6.44
5.53
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
4.04 kW
3.99 kW
COP Tj = Tbiv
2.69
1.58
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.04 kW
3.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1804 kWh
2375 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.07 kW
6.09 kW
El input
1.20 kW
1.85 kW
COP
5.05
3.28
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.79 kW
1.39 kW
Cooling capacity
5.14
5.90
EER
2.87
4.25
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.22 kW
5.71 kW
SEER
4.68
7.24
Pdc Tj = 35°C
5.22 kW
5.71 kW
EER Tj = 35°C
2.81
4.30
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
3.99 kW
4.07 kW
EER Tj = 30°C
3.58
5.93
Cdc Tj = 30 °C
0.987
1.000
Pdc Tj = 25°C
2.35 kW
3.31 kW
EER Tj = 25°C
5.42
8.58
Cdc Tj = 25 °C
0.967
0.963
Pdc Tj = 20°C
2.71 kW
3.58 kW
EER Tj = 20°C
7.71
11.87
Cdc Tj = 20 °C
0.959
0.953
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Annual energy consumption Qce
669 kWh
473 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
230 %
156 %
Prated
4.81 kW
4.57 kW
SCOP
5.83
3.97
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.81 kW
4.57 kW
COP Tj = +2°C
3.30
2.20
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.10 kW
2.75 kW
COP Tj = +7°C
5.63
3.54
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.82 kW
2.61 kW
COP Tj = 12°C
6.65
4.89
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.81 kW
4.57 kW
COP Tj = Tbiv
3.30
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.81 kW
4.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.30
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1102 kWh
1536 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
147 %
101 %
Prated
4.48 kW
3.95 kW
SCOP
3.75
2.61
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.74 kW
2.51 kW
COP Tj = -7°C
2.86
1.97
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
2.26 kW
2.00 kW
COP Tj = +2°C
5.04
3.50
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.68 kW
2.68 kW
COP Tj = +7°C
6.36
4.82
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.83 kW
2.73 kW
COP Tj = 12°C
6.79
5.79
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
3.66 kW
3.22 kW
COP Tj = Tbiv
2.09
1.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.99 kW
3.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.70
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.48 kW
3.95 kW
Annual energy consumption Qhe
2949 kWh
3733 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.66
3.22
COP Tj = -15°C (if TOL<-20°C)
2.09
1.51
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
136 %
Prated
5.01 kW
5.21 kW
SCOP
4.61
3.46
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.43 kW
4.61 kW
COP Tj = -7°C
3.06
2.20
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.81 kW
2.81 kW
COP Tj = +2°C
4.46
3.43
Cdh Tj = +2 °C
0.99
1.00
Pdh Tj = +7°C
2.74 kW
2.42 kW
COP Tj = +7°C
6.25
4.45
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.01 kW
2.68 kW
COP Tj = 12°C
6.44
5.53
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.43 kW
4.61 kW
COP Tj = Tbiv
3.06
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.04 kW
3.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.97 kW
1.22 kW
Annual energy consumption Qhe
2246 kWh
3109 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
131.3 %
COP
3.14
Heating up time
01:00 h:min
Standby power input
29.1 W
Reference hot water temperature
51.6 °C
Mixed water at 40°C
237.7 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
89.3 %
COP
2.16
Heating up time
01:10 h:min
Standby power input
33.7 W
Reference hot water temperature
51.06 °C
Mixed water at 40°C
233.99 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
110.1 %
COP
2.65
Heating up time
01:05 h:min
Standby power input
31.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
235.37 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.07 kW
6.09 kW
El input
1.25 kW
1.90 kW
COP
4.85
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.84 kW
1.44 kW
Cooling capacity
5.14
5.90
EER
2.79
4.10
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.22 kW
5.71 kW
SEER
4.32
6.57
Pdc Tj = 35°C
5.22 kW
5.71 kW
EER Tj = 35°C
2.74
4.14
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
3.99 kW
4.07 kW
EER Tj = 30°C
3.42
5.53
Cdc Tj = 30 °C
0.988
1.000
Pdc Tj = 25°C
2.35 kW
3.31 kW
EER Tj = 25°C
4.86
7.59
Cdc Tj = 25 °C
0.971
0.967
Pdc Tj = 20°C
2.71 kW
3.58 kW
EER Tj = 20°C
6.75
10.18
Cdc Tj = 20 °C
0.964
0.959
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Annual energy consumption Qce
726 kWh
521 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
209 %
145 %
Prated
4.81 kW
4.57 kW
SCOP
5.30
3.70
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.81 kW
4.57 kW
COP Tj = +2°C
3.19
2.15
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.10 kW
2.75 kW
COP Tj = +7°C
5.16
3.33
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.82 kW
2.61 kW
COP Tj = 12°C
5.95
4.47
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.81 kW
4.57 kW
COP Tj = Tbiv
3.19
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.81 kW
4.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.15
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1211 kWh
1649 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
136 %
96 %
Prated
4.48 kW
3.95 kW
SCOP
3.48
2.47
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.74 kW
2.51 kW
COP Tj = -7°C
2.72
1.89
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
2.26 kW
2.00 kW
COP Tj = +2°C
4.54
3.22
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.68 kW
2.68 kW
COP Tj = +7°C
5.68
4.42
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.83 kW
2.73 kW
COP Tj = 12°C
6.06
5.23
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
3.66 kW
3.22 kW
COP Tj = Tbiv
2.03
1.48
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.99 kW
3.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.65
1.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.48 kW
3.95 kW
Annual energy consumption Qhe
3174 kWh
3946 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.66
3.22
COP Tj = -15°C (if TOL<-20°C)
2.03
1.48
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
168 %
127 %
Prated
5.01 kW
5.21 kW
SCOP
4.27
3.26
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.43 kW
4.61 kW
COP Tj = -7°C
2.96
2.15
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.81 kW
2.81 kW
COP Tj = +2°C
4.13
3.24
Cdh Tj = +2 °C
0.99
1.00
Pdh Tj = +7°C
2.74 kW
2.42 kW
COP Tj = +7°C
5.61
4.07
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.01 kW
2.68 kW
COP Tj = 12°C
5.82
5.01
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.43 kW
4.61 kW
COP Tj = Tbiv
2.96
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.04 kW
3.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
1.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.97 kW
1.22 kW
Annual energy consumption Qhe
2424 kWh
3304 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
131.3 %
COP
3.14
Heating up time
01:00 h:min
Standby power input
29.1 W
Reference hot water temperature
51.6 °C
Mixed water at 40°C
237.7 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
89.3 %
COP
2.16
Heating up time
01:10 h:min
Standby power input
33.7 W
Reference hot water temperature
51.06 °C
Mixed water at 40°C
233.99 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
110.1 %
COP
2.65
Heating up time
01:05 h:min
Standby power input
31.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
235.37 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.07 kW
6.09 kW
El input
1.20 kW
1.85 kW
COP
5.05
3.28
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.79 kW
1.39 kW
Cooling capacity
5.14
5.90
EER
2.87
4.25
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.22 kW
5.71 kW
SEER
4.68
7.24
Pdc Tj = 35°C
5.22 kW
5.71 kW
EER Tj = 35°C
2.81
4.30
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
3.99 kW
4.07 kW
EER Tj = 30°C
3.58
5.93
Cdc Tj = 30 °C
0.987
1.000
Pdc Tj = 25°C
2.35 kW
3.31 kW
EER Tj = 25°C
5.42
8.58
Cdc Tj = 25 °C
0.967
0.963
Pdc Tj = 20°C
2.71 kW
3.58 kW
EER Tj = 20°C
7.71
11.87
Cdc Tj = 20 °C
0.959
0.953
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Annual energy consumption Qce
669 kWh
473 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
230 %
156 %
Prated
4.81 kW
4.57 kW
SCOP
5.83
3.97
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.81 kW
4.57 kW
COP Tj = +2°C
3.30
2.20
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.10 kW
2.75 kW
COP Tj = +7°C
5.63
3.54
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.82 kW
2.61 kW
COP Tj = 12°C
6.65
4.89
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.81 kW
4.57 kW
COP Tj = Tbiv
3.30
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.81 kW
4.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.30
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1102 kWh
1536 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
147 %
101 %
Prated
4.48 kW
3.95 kW
SCOP
3.75
2.61
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.74 kW
2.51 kW
COP Tj = -7°C
2.86
1.97
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
2.26 kW
2.00 kW
COP Tj = +2°C
5.04
3.50
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.68 kW
2.68 kW
COP Tj = +7°C
6.36
4.82
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.83 kW
2.73 kW
COP Tj = 12°C
6.79
5.79
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
3.66 kW
3.22 kW
COP Tj = Tbiv
2.09
1.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.99 kW
3.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.70
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.48 kW
3.95 kW
Annual energy consumption Qhe
2949 kWh
3733 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.66
3.22
COP Tj = -15°C (if TOL<-20°C)
2.09
1.51
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
136 %
Prated
5.01 kW
5.21 kW
SCOP
4.61
3.46
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.43 kW
4.61 kW
COP Tj = -7°C
3.06
2.20
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.81 kW
2.81 kW
COP Tj = +2°C
4.46
3.43
Cdh Tj = +2 °C
0.99
1.00
Pdh Tj = +7°C
2.74 kW
2.42 kW
COP Tj = +7°C
6.25
4.45
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.01 kW
2.68 kW
COP Tj = 12°C
6.44
5.53
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
4.43 kW
4.61 kW
COP Tj = Tbiv
3.06
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.04 kW
3.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
6 W
6 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.97 kW
1.22 kW
Annual energy consumption Qhe
2246 kWh
3109 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
131.3 %
COP
3.14
Heating up time
01:00 h:min
Standby power input
29.1 W
Reference hot water temperature
51.6 °C
Mixed water at 40°C
237.7 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
89.3 %
COP
2.16
Heating up time
01:10 h:min
Standby power input
33.7 W
Reference hot water temperature
51.06 °C
Mixed water at 40°C
233.99 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
110.1 %
COP
2.65
Heating up time
01:05 h:min
Standby power input
31.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
235.37 l