1,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.99 kW
17.36 kW
El input
3.61 kW
5.44 kW
COP
4.71
3.19
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
145 %
Prated
12.57 kW
11.81 kW
SCOP
4.65
3.71
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.12 kW
10.45 kW
COP Tj = -7°C
3.31
2.31
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
6.82 kW
6.39 kW
COP Tj = +2°C
4.51
3.64
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
7.60 kW
7.44 kW
COP Tj = +7°C
5.60
4.68
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
7.71 kW
7.56 kW
COP Tj = 12°C
6.89
6.18
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
11.12 kW
10.45 kW
COP Tj = Tbiv
3.31
2.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.54 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.85
1.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
58 W
58 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.03 kW
0.00 kW
Annual energy consumption Qhe
5587 kWh
6587 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.73 kW
17.03 kW
El input
3.94 kW
4.79 kW
COP
3.99
3.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
62 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
193 %
145 %
Prated
12.55 kW
12.34 kW
SCOP
4.91
3.70
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.11 kW
10.92 kW
COP Tj = -7°C
3.23
2.34
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
6.89 kW
6.80 kW
COP Tj = +2°C
4.83
3.58
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
7.30 kW
7.36 kW
COP Tj = +7°C
6.04
4.74
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
7.78 kW
7.39 kW
COP Tj = 12°C
7.46
6.12
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
11.11 kW
10.92 kW
COP Tj = Tbiv
3.23
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.61 kW
12.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.89
2.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
63 °C
63 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
17 W
17 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.01 kW
Annual energy consumption Qhe
5281 kWh
6895 kWh