Certificate holders

Subtype

ETHER DUO 110 - ETHER 110

Certificate Holder
Energy Efficiency Technologies
157 Boulevard Victor Hugo
92110 Clichy
France
Registration number
ICIM-PDC-000139
Certification Body
ICIM S.p.A.
Subtype title
ETHER DUO 110 - ETHER 110
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

4,300 kg

Certification Date
21.03.2022
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

ETHER 110
Configure model
Model name
ETHER 110
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

ETHER DUO 110
Configure model
Model name
ETHER DUO 110
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.70

Heating up time

01:16 h:min

Standby power input

39.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

248 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.15

Heating up time

01:49 h:min

Standby power input

57.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.56

Heating up time

01:28 h:min

Standby power input

52.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

251 l