Certificate holders

Subtype

ETHER DUO 90 - ETHER 90

Certificate Holder
Energy Efficiency Technologies
157 Boulevard Victor Hugo
92110 Clichy
France
Registration number
ICIM-PDC-000137
Certification Body
ICIM S.p.A.
Subtype title
ETHER DUO 90 - ETHER 90
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

4,300 kg

Certification Date
21.03.2022
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

ETHER 90
Configure model
Model name
ETHER 90
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.65 kW

7.67 kW

El input

1.65 kW

2.39 kW

COP

5.25

3.21

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

6.86 kW

6.27 kW

ηs

245 %

153 %

Prated

6.86 kW

6.27 kW

SCOP

6.20

3.90

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.86 kW

6.27 kW

COP Tj = +2°C

4.10

2.45

Pdh Tj = +7°C

4.46 kW

4.05 kW

COP Tj = +7°C

5.44

3.19

Pdh Tj = 12°C

4.36 kW

4.11 kW

COP Tj = 12°C

8.44

5.72

Pdh Tj = Tbiv

6.86 kW

6.27 kW

COP Tj = Tbiv

4.10

2.45

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.86 kW

6.27 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.10

2.45

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1477 kWh

2149 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

14.97 kW

13.72 kW

ηs

150 %

106 %

Prated

14.97 kW

13.72 kW

SCOP

3.84

2.73

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.06 kW

8.30 kW

COP Tj = -7°C

3.65

2.75

Pdh Tj = +2°C

5.53 kW

4.86 kW

COP Tj = +2°C

5.01

3.60

Pdh Tj = +7°C

3.71 kW

3.61 kW

COP Tj = +7°C

6.51

5.09

Pdh Tj = 12°C

4.44 kW

4.30 kW

COP Tj = 12°C

9.48

7.53

Pdh Tj = Tbiv

9.06 kW

8.30 kW

COP Tj = Tbiv

3.65

2.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.33 kW

2.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

0.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

9620 kWh

12389 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

10.38 kW

9.38 kW

ηs

189 %

133 %

Prated

10.38 kW

9.38 kW

SCOP

4.80

3.40

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.18 kW

8.30 kW

COP Tj = -7°C

3.32

2.32

Pdh Tj = +2°C

5.60 kW

5.31 kW

COP Tj = +2°C

4.59

3.22

Pdh Tj = +7°C

3.64 kW

3.47 kW

COP Tj = +7°C

5.98

4.38

Pdh Tj = 12°C

4.44 kW

4.22 kW

COP Tj = 12°C

9.48

6.80

Pdh Tj = Tbiv

9.18 kW

8.30 kW

COP Tj = Tbiv

3.32

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.16 kW

9.73 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

1.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.22 kW

0.00 kW

Annual energy consumption Qhe

4468 kWh

5700 kWh

ETHER DUO 90
Configure model
Model name
ETHER DUO 90
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.65 kW

7.67 kW

El input

1.65 kW

2.39 kW

COP

5.25

3.21

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

6.86 kW

6.27 kW

ηs

245 %

153 %

Prated

6.86 kW

6.27 kW

SCOP

6.20

3.90

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.86 kW

6.27 kW

COP Tj = +2°C

4.10

2.45

Pdh Tj = +7°C

4.46 kW

4.05 kW

COP Tj = +7°C

5.44

3.19

Pdh Tj = 12°C

4.36 kW

4.11 kW

COP Tj = 12°C

8.44

5.72

Pdh Tj = Tbiv

6.86 kW

6.27 kW

COP Tj = Tbiv

4.10

2.45

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.86 kW

6.27 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.10

2.45

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1477 kWh

2149 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

14.97 kW

13.72 kW

ηs

150 %

106 %

Prated

14.97 kW

13.72 kW

SCOP

3.84

2.73

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.06 kW

8.30 kW

COP Tj = -7°C

3.65

2.75

Pdh Tj = +2°C

5.53 kW

4.86 kW

COP Tj = +2°C

5.01

3.60

Pdh Tj = +7°C

3.71 kW

3.61 kW

COP Tj = +7°C

6.51

5.09

Pdh Tj = 12°C

4.44 kW

4.30 kW

COP Tj = 12°C

9.48

7.53

Pdh Tj = Tbiv

9.06 kW

8.30 kW

COP Tj = Tbiv

3.65

2.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.33 kW

2.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

0.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

9620 kWh

12389 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

10.38 kW

9.38 kW

ηs

189 %

133 %

Prated

10.38 kW

9.38 kW

SCOP

4.80

3.40

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.18 kW

8.30 kW

COP Tj = -7°C

3.32

2.32

Pdh Tj = +2°C

5.60 kW

5.31 kW

COP Tj = +2°C

4.59

3.22

Pdh Tj = +7°C

3.64 kW

3.47 kW

COP Tj = +7°C

5.98

4.38

Pdh Tj = 12°C

4.44 kW

4.22 kW

COP Tj = 12°C

9.48

6.80

Pdh Tj = Tbiv

9.18 kW

8.30 kW

COP Tj = Tbiv

3.32

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.16 kW

9.73 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

1.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.22 kW

0.00 kW

Annual energy consumption Qhe

4468 kWh

5700 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.70

Heating up time

01:16 h:min

Standby power input

39.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

248 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.15

Heating up time

01:49 h:min

Standby power input

57.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.56

Heating up time

01:28 h:min

Standby power input

52.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

251 l