9,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
63.73 kW
64.59 kW
El input
14.26 kW
21.67 kW
COP
4.47
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
155 %
Prated
63.73 kW
64.59 kW
SCOP
5.14
4.08
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
56.38 kW
57.14 kW
COP Tj = -7°C
4.64
3.26
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
33.56 kW
33.86 kW
COP Tj = +2°C
5.36
4.26
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
33.50 kW
33.75 kW
COP Tj = +7°C
5.51
4.57
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
33.44 kW
33.64 kW
COP Tj = 12°C
5.64
4.85
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
63.73 kW
64.59 kW
COP Tj = Tbiv
4.47
2.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
63.73 kW
64.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.47
2.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
68 °C
68 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
25592 kWh
32669 kWh