6,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
38.7 kW
38.39 kW
El input
8.7 kW
10.32 kW
COP
4.45
3.72
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
164 %
Prated
38.7 kW
38.39 kW
SCOP
5.06
4.29
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
34.23 kW
33.96 kW
COP Tj = -7°C
4.62
3.63
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
20.29 kW
20.55 kW
COP Tj = +2°C
5.31
4.32
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
20.23 kW
20.49 kW
COP Tj = +7°C
5.44
4.61
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
20.19 kW
20.39 kW
COP Tj = 12°C
5.56
5.12
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
38.7 kW
38.39 kW
COP Tj = Tbiv
4.45
3.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
38.70 kW
38.39 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.45
3.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
68 °C
68 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
15792 kWh
18477 kWh