4,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
22.9 kW
23.28 kW
El input
5.01 kW
7.73 kW
COP
4.57
3.01
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
153 %
Prated
22.9 kW
23.28 kW
SCOP
5.14
4.02
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
20.26 kW
20.59 kW
COP Tj = -7°C
4.75
3.27
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
11.78 kW
11.79 kW
COP Tj = +2°C
5.52
4.3
Cdh Tj = +2 °C
0.99
1.00
Pdh Tj = +7°C
11.76 kW
11.78 kW
COP Tj = +7°C
5.71
4.66
Cdh Tj = +7 °C
0.99
1.00
Pdh Tj = 12°C
11.75 kW
11.77 kW
COP Tj = 12°C
5.85
5.22
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
22.9 kW
23.28 kW
COP Tj = Tbiv
4.57
3.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
22.90 kW
23.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.57
3.01
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
68 °C
68 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
9208 kWh
11952 kWh