Certificate holders

Subtype

Acond PRO-R

Certificate Holder
Acond a.s.
Štěrboholská 1434/102a
102 00 Hostivař, Praha
Czech Republic
Registration number
037-0076-22 / rev. 1
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
Acond PRO-R
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

2,750 kg

Certification Date
17.03.2022
Testing basis
HP Keymark scheme rules rev. no. 9
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

Acond PRO-R SP
Configure model
Model name
Acond PRO-R SP
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.77 kW

7.41 kW

El input

1.30 kW

2.25 kW

COP

5.22

3.29

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

dB(A)

0 dB(A)

Sound power level outdoor

dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

154 %

Prated

10.38 kW

10.17 kW

SCOP

5.05

3.93

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.23 kW

9.00 kW

COP Tj = -7°C

3.24

2.50

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.46 kW

5.53 kW

COP Tj = +2°C

5.03

3.87

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.81 kW

3.52 kW

COP Tj = +7°C

6.33

4.97

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.05 kW

3.88 kW

COP Tj = 12°C

7.42

6.14

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

10.38 kW

10.17 kW

COP Tj = Tbiv

2.76

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.38 kW

10.17 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

16 W

16 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4246 kWh

5351 kWh

Acond PRO-R
Configure model
Model name
Acond PRO-R
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.77 kW

7.41 kW

El input

1.30 kW

2.25 kW

COP

5.22

3.29

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

dB(A)

0 dB(A)

Sound power level outdoor

dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

154 %

Prated

10.38 kW

10.17 kW

SCOP

5.05

3.93

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.23 kW

9.00 kW

COP Tj = -7°C

3.24

2.50

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.46 kW

5.53 kW

COP Tj = +2°C

5.03

3.87

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.81 kW

3.52 kW

COP Tj = +7°C

6.33

4.97

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.05 kW

3.88 kW

COP Tj = 12°C

7.42

6.14

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

10.38 kW

10.17 kW

COP Tj = Tbiv

2.76

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.38 kW

10.17 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

16 W

16 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4246 kWh

5351 kWh