1,650 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.30 kW
7.50 kW
El input
1.56 kW
2.35 kW
COP
5.31
3.19
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
41 dB(A)
Sound power level outdoor
dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
210 %
146 %
Prated
8.08 kW
6.88 kW
SCOP
5.32
3.72
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.15 kW
6.09 kW
COP Tj = -7°C
3.30
2.27
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.65 kW
3.94 kW
COP Tj = +2°C
5.17
3.56
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.91 kW
2.52 kW
COP Tj = +7°C
7.08
4.70
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.85 kW
1.72 kW
COP Tj = 12°C
9.46
9.71
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.15 kW
6.09 kW
COP Tj = Tbiv
3.30
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.42 kW
4.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.06
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
1.66 kW
1.91 kW
Annual energy consumption Qhe
3141 kWh
3824 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.60
Heating up time
01:50 h:min
Standby power input
54.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
188 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.30 kW
9.60 kW
El input
2.01 kW
3.10 kW
COP
5.01
3.10
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
41 dB(A)
Sound power level outdoor
dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
208 %
143 %
Prated
9.55 kW
8.57 kW
SCOP
5.27
3.73
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.45 kW
7.58 kW
COP Tj = -7°C
3.18
2.02
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.23 kW
4.44 kW
COP Tj = +2°C
5.03
3.63
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.47 kW
2.92 kW
COP Tj = +7°C
7.33
4.95
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.96 kW
1.71 kW
COP Tj = 12°C
9.94
6.56
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.45 kW
7.58 kW
COP Tj = Tbiv
3.18
2.02
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.38 kW
5.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.97
1.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
2.17 kW
3.11 kW
Annual energy consumption Qhe
3747 kWh
4749 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.60
Heating up time
01:50 h:min
Standby power input
54.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
188 l