1,840 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.13 kW
12.07 kW
El input
2.42 kW
3.89 kW
COP
5.00
3.10
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
41 dB(A)
Sound power level outdoor
dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
197 %
140 %
Prated
12.08 kW
11.70 kW
SCOP
5.00
3.56
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.69 kW
10.35 kW
COP Tj = -7°C
3.07
2.05
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.57 kW
6.62 kW
COP Tj = +2°C
4.68
3.51
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.48 kW
4.45 kW
COP Tj = +7°C
6.90
4.77
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.67 kW
3.04 kW
COP Tj = 12°C
9.96
6.43
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.69 kW
10.35 kW
COP Tj = Tbiv
3.07
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.95 kW
9.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.79
1.85
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
1.13 kW
2.11 kW
Annual energy consumption Qhe
4994 kWh
6793 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.90
Heating up time
01:47 h:min
Standby power input
54.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
265 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.51 kW
13.85 kW
El input
3.09 kW
4.53 kW
COP
4.70
3.05
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
41 dB(A)
Sound power level outdoor
dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
193 %
138 %
Prated
13.94 kW
12.57 kW
SCOP
4.91
3.52
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.33 kW
11.12 kW
COP Tj = -7°C
2.87
2.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.97 kW
6.82 kW
COP Tj = +2°C
4.62
3.41
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.21 kW
4.73 kW
COP Tj = +7°C
7.07
4.85
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.67 kW
3.03 kW
COP Tj = 12°C
9.95
6.43
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.33 kW
11.12 kW
COP Tj = Tbiv
2.87
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.90 kW
9.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
2.04 kW
2.69 kW
Annual energy consumption Qhe
5868 kWh
7380 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.90
Heating up time
01:47 h:min
Standby power input
54.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
265 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.01 kW
16.00 kW
El input
3.52 kW
5.52 kW
COP
4.55
2.90
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
41 dB(A)
Sound power level outdoor
dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
193 %
136 %
Prated
15.62 kW
13.33 kW
SCOP
4.89
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.82 kW
11.79 kW
COP Tj = -7°C
2.86
2.04
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.55 kW
7.04 kW
COP Tj = +2°C
4.59
3.34
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.88 kW
4.72 kW
COP Tj = +7°C
7.13
4.85
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.67 kW
3.03 kW
COP Tj = 12°C
9.95
6.43
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
13.82 kW
11.79 kW
COP Tj = Tbiv
2.86
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.64 kW
10.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
2.98 kW
2.66 kW
Annual energy consumption Qhe
6602 kWh
7915 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
123 %
COP
2.90
Heating up time
01:47 h:min
Standby power input
54.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
265 l