2,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.08 kW
5.87 kW
El input
1.13 kW
1.91 kW
COP
5.45
3.08
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
44 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
139 %
Prated
8.10 kW
7.40 kW
SCOP
5.08
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.22 kW
6.37 kW
COP Tj = -7°C
3.35
2.43
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.60 kW
4.36 kW
COP Tj = +2°C
5.22
3.71
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.88 kW
2.78 kW
COP Tj = +7°C
6.13
4.45
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.77 kW
2.88 kW
COP Tj = 12°C
6.90
5.67
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.00 kW
7.40 kW
COP Tj = Tbiv
3.04
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.00 kW
7.41 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.01
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
67 °C
67 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.10 kW
0.00 kW
Annual energy consumption Qhe
3295 kWh
4192 kWh
Heating
EN 14511-2
Medium temperature
Heat output
5.87 kW
El input
1.91 kW
COP
3.08
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
0 dB(A)
Sound power level outdoor
42 dB(A)
EN 14825
Medium temperature
ηs
139 %
Prated
7.40 kW
SCOP
3.65
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
6.37 kW
COP Tj = -7°C
2.43
Cdh Tj = -7 °C
0.900
Pdh Tj = +2°C
4.36 kW
COP Tj = +2°C
3.71
Cdh Tj = +2 °C
0.900
Pdh Tj = +7°C
2.78 kW
COP Tj = +7°C
4.45
Cdh Tj = +7 °C
0.900
Pdh Tj = 12°C
2.88 kW
COP Tj = 12°C
5.67
Cdh Tj = +12 °C
0.900
Pdh Tj = Tbiv
7.41 kW
COP Tj = Tbiv
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.41 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.01
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
67 °C
Poff
14 W
PTO
14 W
PSB
14 W
PCK
14 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
4192 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
116 %
COP
2.74
Heating up time
1:46 h:min
Standby power input
68.2 W
Reference hot water temperature
55.5 °C
Mixed water at 40°C
260 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.02 kW
5.87 kW
El input
1.12 kW
1.92 kW
COP
5.41
3.06
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
137 %
Prated
8.40 kW
7.80 kW
SCOP
4.93
3.57
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.30 kW
6.46 kW
COP Tj = -7°C
3.45
2.44
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.83 kW
4.48 kW
COP Tj = +2°C
4.87
3.72
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.04 kW
2.75 kW
COP Tj = +7°C
6.19
4.25
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.01 kW
2.92 kW
COP Tj = 12°C
7.19
5.36
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.05 kW
7.48 kW
COP Tj = Tbiv
3.11
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.05 kW
7.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.11
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
67 °C
67 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.35 kW
0.32 kW
Annual energy consumption Qhe
3520 kWh
4510 kWh
Heating
EN 14511-2
Medium temperature
Heat output
5.87 kW
El input
1.92 kW
COP
3.06
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
0 dB(A)
Sound power level outdoor
42 dB(A)
EN 14825
Medium temperature
ηs
137 %
Prated
7.80 kW
SCOP
3.57
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
6.46 kW
COP Tj = -7°C
2.44
Cdh Tj = -7 °C
0.900
Pdh Tj = +2°C
4.48 kW
COP Tj = +2°C
3.72
Cdh Tj = +2 °C
0.900
Pdh Tj = +7°C
2.75 kW
COP Tj = +7°C
4.25
Cdh Tj = +7 °C
0.900
Pdh Tj = 12°C
2.92 kW
COP Tj = 12°C
5.36
Cdh Tj = +12 °C
0.900
Pdh Tj = Tbiv
7.48 kW
COP Tj = Tbiv
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
67 °C
Poff
14 W
PTO
14 W
PSB
14 W
PCK
14 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.32 kW
Annual energy consumption Qhe
4510 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.73
Heating up time
1:46 h:min
Standby power input
69.0 W
Reference hot water temperature
55.4 °C
Mixed water at 40°C
261 l