1,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.13 kW
5.61 kW
El input
1.15 kW
1.72 kW
COP
5.33
3.27
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
1.38 kW
Cooling capacity
5.81
EER
4.21
EN 14825
+7°C/+12°C
Pdesignc
5.81 kW
SEER
6.98
Pdc Tj = 35°C
5.81 kW
EER Tj = 35°C
4.21
Pdc Tj = 30°C
4.54 kW
EER Tj = 30°C
5.82
Cdc Tj = 30 °C
0.980
Pdc Tj = 25°C
2.77 kW
EER Tj = 25°C
8.83
Cdc Tj = 25 °C
0.950
Pdc Tj = 20°C
3.12 kW
EER Tj = 20°C
10.41
Cdc Tj = 20 °C
0.950
Poff
15 W
PTO
24 W
PSB
15 W
PCK
0 W
Annual energy consumption Qce
500 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
234 %
162 %
Prated
6.10 kW
5.60 kW
SCOP
6.06
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.13 kW
5.61 kW
COP Tj = +2°C
5.33
3.27
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
3.85 kW
3.53 kW
COP Tj = +7°C
6.14
3.93
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
1.67 kW
1.66 kW
COP Tj = 12°C
6.92
5.17
Cdh Tj = +12 °C
1.000
1.000
Pdh Tj = Tbiv
6.13 kW
5.61 kW
COP Tj = Tbiv
5.33
3.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.13 kW
5.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.33
3.27
WTOL
35 °C
55 °C
Poff
15 W
15 W
PTO
24 W
24 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1345 kWh
1766 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
166 %
Prated
6.05 kW
5.60 kW
SCOP
5.05
4.36
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.47 kW
3.68 kW
COP Tj = -7°C
6.68
4.26
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
2.04 kW
2.06 kW
COP Tj = +2°C
7.26
4.86
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
1.31 kW
1.28 kW
COP Tj = +7°C
6.97
4.03
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
0.99 kW
0.95 kW
COP Tj = 12°C
6.99
4.75
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.13 kW
5.61 kW
COP Tj = Tbiv
5.33
3.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.13 kW
5.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.33
3.27
WTOL
35 °C
55 °C
Poff
15 W
15 W
PTO
24 W
24 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2952 kWh
3169 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
252 %
158 %
Prated
6.10 kW
5.60 kW
SCOP
6.49
4.15
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.20 kW
4.83 kW
COP Tj = -7°C
5.49
3.50
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.47 kW
3.13 kW
COP Tj = +2°C
6.68
4.46
Cdh Tj = +2 °C
0.900
1.000
Pdh Tj = +7°C
2.16 kW
1.92 kW
COP Tj = +7°C
7.66
5.10
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
0.99 kW
0.80 kW
COP Tj = 12°C
6.99
4.28
Cdh Tj = +12 °C
0.900
1.000
Pdh Tj = Tbiv
6.13 kW
5.61 kW
COP Tj = Tbiv
5.33
3.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.13 kW
5.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.33
3.27
WTOL
35 °C
55 °C
Poff
15 W
15 W
PTO
24 W
24 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1941 kWh
2785 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
1:48 h:min
Standby power input
27.6 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
239 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
1:48 h:min
Standby power input
27.6 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
239 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
1:48 h:min
Standby power input
27.6 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
239 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.13 kW
5.61 kW
El input
1.15 kW
1.72 kW
COP
5.33
3.27
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
1.38 kW
Cooling capacity
5.81
EER
4.21
EN 14825
+7°C/+12°C
Pdesignc
5.81 kW
SEER
6.98
Pdc Tj = 35°C
5.81 kW
EER Tj = 35°C
4.21
Pdc Tj = 30°C
4.54 kW
EER Tj = 30°C
5.82
Cdc Tj = 30 °C
0.980
Pdc Tj = 25°C
2.77 kW
EER Tj = 25°C
8.83
Cdc Tj = 25 °C
0.950
Pdc Tj = 20°C
3.12 kW
EER Tj = 20°C
10.41
Cdc Tj = 20 °C
0.950
Poff
15 W
PTO
24 W
PSB
15 W
PCK
0 W
Annual energy consumption Qce
500 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
234 %
162 %
Prated
6.10 kW
5.60 kW
SCOP
6.06
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.13 kW
5.61 kW
COP Tj = +2°C
5.33
3.27
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
3.85 kW
3.53 kW
COP Tj = +7°C
6.14
3.93
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
1.67 kW
1.66 kW
COP Tj = 12°C
6.92
5.17
Cdh Tj = +12 °C
1.000
1.000
Pdh Tj = Tbiv
6.13 kW
5.61 kW
COP Tj = Tbiv
5.33
3.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.13 kW
5.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.33
3.27
WTOL
35 °C
55 °C
Poff
15 W
15 W
PTO
24 W
24 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1345 kWh
1766 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
166 %
Prated
6.05 kW
5.60 kW
SCOP
5.05
4.36
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.47 kW
3.68 kW
COP Tj = -7°C
6.68
4.26
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
2.04 kW
2.06 kW
COP Tj = +2°C
7.26
4.86
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
1.31 kW
1.28 kW
COP Tj = +7°C
6.97
4.03
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
0.99 kW
0.95 kW
COP Tj = 12°C
6.99
4.75
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.13 kW
5.61 kW
COP Tj = Tbiv
5.33
3.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.13 kW
5.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.33
3.27
WTOL
35 °C
55 °C
Poff
15 W
15 W
PTO
24 W
24 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2952 kWh
3169 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
252 %
158 %
Prated
6.10 kW
5.60 kW
SCOP
6.49
4.15
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.20 kW
4.83 kW
COP Tj = -7°C
5.49
3.50
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.47 kW
3.13 kW
COP Tj = +2°C
6.68
4.46
Cdh Tj = +2 °C
0.900
1.000
Pdh Tj = +7°C
2.16 kW
1.92 kW
COP Tj = +7°C
7.66
5.10
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
0.99 kW
0.80 kW
COP Tj = 12°C
6.99
4.28
Cdh Tj = +12 °C
0.900
1.000
Pdh Tj = Tbiv
6.13 kW
5.61 kW
COP Tj = Tbiv
5.33
3.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.13 kW
5.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.33
3.27
WTOL
35 °C
55 °C
Poff
15 W
15 W
PTO
24 W
24 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1941 kWh
2785 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
1:48 h:min
Standby power input
27.6 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
239 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
1:48 h:min
Standby power input
27.6 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
239 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
1:48 h:min
Standby power input
27.6 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
239 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.13 kW
5.61 kW
El input
1.15 kW
1.72 kW
COP
5.33
3.27
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
1.38 kW
Cooling capacity
5.81
EER
4.21
EN 14825
+7°C/+12°C
Pdesignc
5.81 kW
SEER
6.98
Pdc Tj = 35°C
5.81 kW
EER Tj = 35°C
4.21
Pdc Tj = 30°C
4.54 kW
EER Tj = 30°C
5.82
Cdc Tj = 30 °C
0.980
Pdc Tj = 25°C
2.77 kW
EER Tj = 25°C
8.83
Cdc Tj = 25 °C
0.950
Pdc Tj = 20°C
3.12 kW
EER Tj = 20°C
10.41
Cdc Tj = 20 °C
0.950
Poff
15 W
PTO
24 W
PSB
15 W
PCK
0 W
Annual energy consumption Qce
500 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
247 %
168 %
Prated
6.10 kW
5.60 kW
SCOP
6.37
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.13 kW
5.61 kW
COP Tj = +2°C
5.33
3.27
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
3.85 kW
3.53 kW
COP Tj = +7°C
6.14
3.93
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
1.67 kW
1.66 kW
COP Tj = 12°C
6.92
5.17
Cdh Tj = +12 °C
1.000
1.000
Pdh Tj = Tbiv
6.13 kW
5.61 kW
COP Tj = Tbiv
5.33
3.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.13 kW
5.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.33
3.27
WTOL
35 °C
55 °C
Poff
15 W
15 W
PTO
24 W
24 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1279 kWh
1699 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
196 %
168 %
Prated
6.05 kW
5.60 kW
SCOP
5.11
4.40
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.47 kW
3.68 kW
COP Tj = -7°C
6.68
4.26
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
2.04 kW
2.06 kW
COP Tj = +2°C
7.26
4.86
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
1.31 kW
1.28 kW
COP Tj = +7°C
6.97
4.03
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
0.99 kW
0.95 kW
COP Tj = 12°C
6.99
4.75
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.13 kW
5.61 kW
COP Tj = Tbiv
5.33
3.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.13 kW
5.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.33
3.27
WTOL
35 °C
55 °C
Poff
15 W
15 W
PTO
24 W
24 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2919 kWh
3138 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
259 %
162 %
Prated
6.10 kW
5.60 kW
SCOP
6.68
4.24
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.20 kW
4.83 kW
COP Tj = -7°C
5.49
3.50
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.47 kW
3.13 kW
COP Tj = +2°C
6.68
4.46
Cdh Tj = +2 °C
0.900
1.000
Pdh Tj = +7°C
2.16 kW
1.92 kW
COP Tj = +7°C
7.66
5.10
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
0.99 kW
0.80 kW
COP Tj = 12°C
6.99
4.28
Cdh Tj = +12 °C
0.900
1.000
Pdh Tj = Tbiv
6.13 kW
5.61 kW
COP Tj = Tbiv
5.33
3.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.13 kW
5.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.33
3.27
WTOL
35 °C
55 °C
Poff
15 W
15 W
PTO
24 W
24 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1886 kWh
2730 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
1:48 h:min
Standby power input
27.6 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
239 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
1:48 h:min
Standby power input
27.6 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
239 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
1:48 h:min
Standby power input
27.6 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
239 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.13 kW
5.61 kW
El input
1.15 kW
1.72 kW
COP
5.33
3.27
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
1.38 kW
Cooling capacity
5.81
EER
4.21
EN 14825
+7°C/+12°C
Pdesignc
5.81 kW
SEER
6.98
Pdc Tj = 35°C
5.81 kW
EER Tj = 35°C
4.21
Pdc Tj = 30°C
4.54 kW
EER Tj = 30°C
5.82
Cdc Tj = 30 °C
0.980
Pdc Tj = 25°C
2.77 kW
EER Tj = 25°C
8.83
Cdc Tj = 25 °C
0.950
Pdc Tj = 20°C
3.12 kW
EER Tj = 20°C
10.41
Cdc Tj = 20 °C
0.950
Poff
15 W
PTO
24 W
PSB
15 W
PCK
0 W
Annual energy consumption Qce
500 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
247 %
168 %
Prated
6.10 kW
5.60 kW
SCOP
6.37
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.13 kW
5.61 kW
COP Tj = +2°C
5.33
3.27
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
3.85 kW
3.53 kW
COP Tj = +7°C
6.14
3.93
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
1.67 kW
1.66 kW
COP Tj = 12°C
6.92
5.17
Cdh Tj = +12 °C
1.000
1.000
Pdh Tj = Tbiv
6.13 kW
5.61 kW
COP Tj = Tbiv
5.33
3.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.13 kW
5.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.33
3.27
WTOL
35 °C
55 °C
Poff
15 W
15 W
PTO
24 W
24 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1279 kWh
1699 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
196 %
168 %
Prated
6.05 kW
5.60 kW
SCOP
5.11
4.40
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.47 kW
3.68 kW
COP Tj = -7°C
6.68
4.26
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
2.04 kW
2.06 kW
COP Tj = +2°C
7.26
4.86
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
1.31 kW
1.28 kW
COP Tj = +7°C
6.97
4.03
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
0.99 kW
0.95 kW
COP Tj = 12°C
6.99
4.75
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.13 kW
5.61 kW
COP Tj = Tbiv
5.33
3.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.13 kW
5.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.33
3.27
WTOL
35 °C
55 °C
Poff
15 W
15 W
PTO
24 W
24 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2919 kWh
3138 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
259 %
162 %
Prated
6.10 kW
5.60 kW
SCOP
6.68
4.24
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.20 kW
4.83 kW
COP Tj = -7°C
5.49
3.50
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.47 kW
3.13 kW
COP Tj = +2°C
6.68
4.46
Cdh Tj = +2 °C
0.900
1.000
Pdh Tj = +7°C
2.16 kW
1.92 kW
COP Tj = +7°C
7.66
5.10
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
0.99 kW
0.80 kW
COP Tj = 12°C
6.99
4.28
Cdh Tj = +12 °C
0.900
1.000
Pdh Tj = Tbiv
6.13 kW
5.61 kW
COP Tj = Tbiv
5.33
3.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.13 kW
5.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.33
3.27
WTOL
35 °C
55 °C
Poff
15 W
15 W
PTO
24 W
24 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1886 kWh
2730 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
1:48 h:min
Standby power input
27.6 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
239 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
1:48 h:min
Standby power input
27.6 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
239 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
1:48 h:min
Standby power input
27.6 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
239 l