Certificate holders

Subtype

HPS.Z 12-16kW/400 V

Certificate Holder
Kospel SP. z o.o.
ul. Olchowa 1
75-136 Koszalin
Poland
Registration number
011-1W0439
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
HPS.Z 12-16kW/400 V
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,500 kg

Certification Date
15.12.2021
Testing basis
HP KEYMARK certification scheme rules rev. 9
Generate PDF Export model CSV
  • Number of models 2

Models

HPSO-12/400 + HPSI-9
Configure model
Model name
HPSO-12/400 + HPSI-9
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.50 kW

9.72 kW

El input

2.58 kW

3.65 kW

COP

4.45

2.66

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.80 kW

ηs

156 %

110 %

Prated

9.00 kW

8.79 kW

SCOP

3.98

2.83

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

7.98 kW

7.70 kW

COP Tj = -7°C

2.87

1.93

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

5.63 kW

5.17 kW

COP Tj = +2°C

3.90

3.50

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

5.78 kW

8.52 kW

COP Tj = +7°C

4.86

3.66

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

14.35 kW

6.41 kW

COP Tj = 12°C

6.08

4.84

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

7.98 kW

7.70 kW

COP Tj = Tbiv

2.87

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.54 kW

6.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.48 kW

1.85 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

4696 kWh

6362 kWh

HPSO-16/400 + HPSI-9
Configure model
Model name
HPSO-16/400 + HPSI-9
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.74 kW

12.67 kW

El input

3.60 kW

4.95 kW

COP

4.37

2.62

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

10.80 kW

ηs

151 %

111 %

Prated

12.80 kW

10.83 kW

SCOP

3.85

2.85

Tbiv

-7 °C

-4 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

11.33 kW

9.20 kW

COP Tj = -7°C

2.46

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

7.16 kW

6.61 kW

COP Tj = +2°C

3.70

2.77

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

5.98 kW

5.08 kW

COP Tj = +7°C

5.17

3.74

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

7.17 kW

6.41 kW

COP Tj = 12°C

6.92

4.84

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

11.33 kW

8.33 kW

COP Tj = Tbiv

2.46

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.68 kW

9.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.12 kW

1.32 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

26449 kWh

22384 kWh