1,000 kg
Domestic Hot Water (DHW)
Warmer Climate
EN 12102-2
Sound power level indoor
51 dB(A)
EN 16147
Declared load profile
XL
Efficiency ηDHW
160 %
COP
3.90
Heating up time
7:54 h:min
Standby power input
24.0 W
Reference hot water temperature
53.2 °C
Mixed water at 40°C
340 l
Average Climate
EN 12102-2
Sound power level indoor
51 dB(A)
EN 16147
Declared load profile
XL
Efficiency ηDHW
138 %
COP
3.37
Heating up time
9:29 h:min
Standby power input
28.0 W
Reference hot water temperature
53.2 °C
Mixed water at 40°C
340 l
Operating test
EN 16147
Temperature operating range
passed
Safety devices checking test
passed
Condensate draining
passed
Domestic Hot Water (DHW)
Warmer Climate
EN 12102-2
Sound power level indoor
51 dB(A)
EN 16147
Declared load profile
L
Efficiency ηDHW
160 %
COP
3.90
Heating up time
7:54 h:min
Standby power input
24.0 W
Reference hot water temperature
53.2 °C
Mixed water at 40°C
333 l
Average Climate
EN 12102-2
Sound power level indoor
51 dB(A)
EN 16147
Declared load profile
XL
Efficiency ηDHW
138 %
COP
3.37
Heating up time
9:29 h:min
Standby power input
28.0 W
Reference hot water temperature
53.2 °C
Mixed water at 40°C
333 l
Operating test
EN 16147
Temperature operating range
passed
Safety devices checking test
passed
Condensate draining
passed