Certificate holders

Subtype

DE DIETRICH STRATEO 6/8 MR/E R32

Certificate Holder
BDR Thermea FR (DE DIETRICH)
57 rue de la Gare
67580 Mertzwiller
France
Registration number
007-DM0102
Certification Body
Kiwa Nederland B.V.
Subtype title
DE DIETRICH STRATEO 6/8 MR/E R32
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,200 kg

Certification Date
18.11.2022
Testing basis
European KEYMARK Scheme for Heat Pumps (v9)
Generate PDF Export model CSV Download certificate
  • Number of models 8

Models

AWHPR 6 MR + MIC-1C V190 R32
Configure model
Model name
AWHPR 6 MR + MIC-1C V190 R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.40 kW

5.70 kW

El input

1.28 kW

1.97 kW

COP

5.00

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.30 kW

1.43 kW

Cooling capacity

6.50

7.00

EER

2.83

4.88

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

6.5 kW

7.0 kW

SEER

3.95

5.99

Pdc Tj = 35°C

6.50 kW

7.00 kW

EER Tj = 35°C

2.83

4.88

Pdc Tj = 30°C

4.90 kW

5.39 kW

EER Tj = 30°C

3.99

6.65

Pdc Tj = 25°C

3.10 kW

3.32 kW

EER Tj = 25°C

4.55

4.93

Pdc Tj = 20°C

1.37 kW

1.78 kW

EER Tj = 20°C

3.96

9.48

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

987 kWh

701 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

132 %

Prated

6.50 kW

6.00 kW

SCOP

4.50

3.37

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.50 kW

COP Tj = -7°C

3.16

2.22

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.50 kW

3.40 kW

COP Tj = +2°C

4.48

3.37

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.25 kW

2.10 kW

COP Tj = +7°C

5.61

4.07

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

2.50 kW

2.50 kW

COP Tj = 12°C

6.92

6.58

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

6.60 kW

5.50 kW

COP Tj = Tbiv

2.68

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.60 kW

5.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: PSUP

0 kW

0.7 kW

Annual energy consumption Qhe

2986 kWh

3679 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

207 %

141 %

Prated

6.50 kW

6.00 kW

SCOP

5.24

3.61

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.50 kW

6.00 kW

COP Tj = +2°C

3.40

2.27

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.30 kW

4.05 kW

COP Tj = +7°C

5.30

3.16

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

1.86 kW

1.90 kW

COP Tj = 12°C

6.07

4.70

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

6.50 kW

6.00 kW

COP Tj = Tbiv

3.40

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.50 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.40

2.27

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

1658 kWh

2222 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

123 %

COP

2.84

Heating up time

01:35 h:min

Standby power input

28.2 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

277 l

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

149 %

COP

3.50

Heating up time

01:28 h:min

Standby power input

36.5 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

277 l

AWHPR 6 MR + MIC-2C V190 R32
Configure model
Model name
AWHPR 6 MR + MIC-2C V190 R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.40 kW

5.70 kW

El input

1.36 kW

2.05 kW

COP

4.70

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.38 kW

1.51 kW

Cooling capacity

6.50

7.00

EER

2.74

4.64

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

6.50 kW

7.00 kW

SEER

3.55

5.17

Pdc Tj = 35°C

6.50 kW

7.00 kW

EER Tj = 35°C

2.74

4.64

Pdc Tj = 30°C

4.90 kW

5.39 kW

EER Tj = 30°C

3.76

6.09

Cdc Tj = 30 °C

 

 

Pdc Tj = 25°C

3.10 kW

3.32 kW

EER Tj = 25°C

4.10

4.44

Cdc Tj = 25 °C

 

 

Pdc Tj = 20°C

1.37 kW

1.78 kW

EER Tj = 20°C

3.25

6.77

Cdc Tj = 20 °C

 

 

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1099 kWh

812 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

121 %

Prated

6.50 kW

6.00 kW

SCOP

4.04

3.10

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.50 kW

COP Tj = -7°C

3.04

2.15

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.50 kW

3.40 kW

COP Tj = +2°C

4.09

3.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.25 kW

2.10 kW

COP Tj = +7°C

4.73

3.55

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

2.50 kW

2.50 kW

COP Tj = 12°C

5.73

5.50

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

6.60 kW

5.50 kW

COP Tj = Tbiv

2.60

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.60 kW

5.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.70 kW

Annual energy consumption Qhe

3321 kWh

4004 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

179 %

127 %

Prated

6.50 kW

6.00 kW

SCOP

4.54

3.25

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.50 kW

6.00 kW

COP Tj = +2°C

3.27

2.21

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.30 kW

4.05 kW

COP Tj = +7°C

4.85

2.99

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

1.86 kW

1.90 kW

COP Tj = 12°C

4.88

3.96

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

6.50 kW

6.00 kW

COP Tj = Tbiv

3.27

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.50 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.27

2.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1913 kWh

2466 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

123 %

COP

2.84

Heating up time

01:35 h:min

Standby power input

28.2 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

277 l

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

149 %

COP

3.50

Heating up time

01:28 h:min

Standby power input

36.5 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

277 l

AWHPR 8 MR + MIC-1C V190 R32
Configure model
Model name
AWHPR 8 MR + MIC-1C V190 R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.6 kW

8.0 kW

El input

1.66 kW

2.91 kW

COP

4.57

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.33 kW

1.45 kW

Cooling capacity

6.50

7.10

EER

2.79

4.88

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

6.5 kW

7.1 kW

SEER

4.32

5.82

Pdc Tj = 35°C

6.50 kW

7.10 kW

EER Tj = 35°C

2.79

4.88

Pdc Tj = 30°C

4.97 kW

5.65 kW

EER Tj = 30°C

3.96

6.71

Pdc Tj = 25°C

3.35 kW

3.18 kW

EER Tj = 25°C

4.74

5.26

Pdc Tj = 20°C

1.55 kW

1.67 kW

EER Tj = 20°C

5.50

7.40

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

904 kWh

732 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

125 %

Prated

7.00 kW

7.00 kW

SCOP

4.48

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.19 kW

6.19 kW

COP Tj = -7°C

2.97

1.95

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.12 kW

3.79 kW

COP Tj = +2°C

4.46

3.24

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

2.78 kW

2.49 kW

COP Tj = +7°C

5.70

4.10

Cdh Tj = +7 °C

0.97

0.97

Pdh Tj = 12°C

2.67 kW

2.55 kW

COP Tj = 12°C

7.80

6.10

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

6.19 kW

6.19 kW

COP Tj = Tbiv

2.97

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.64 kW

4.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.58

1.66

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: PSUP

0.36 kW

2.1 kW

Annual energy consumption Qhe

3225 kWh

4504 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

214 %

149 %

Prated

7.00 kW

6.60 kW

SCOP

5.41

3.81

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.00 kW

6.60 kW

COP Tj = +2°C

3.25

2.12

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.70 kW

4.58 kW

COP Tj = +7°C

5.11

3.36

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

2.11 kW

2.00 kW

COP Tj = 12°C

6.71

5.00

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

7.00 kW

6.60 kW

COP Tj = Tbiv

3.25

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.25

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1728 kWh

2315 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

108 %

COP

2.50

Heating up time

01:25 h:min

Standby power input

31.9 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

278 l

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

143 %

COP

3.40

Heating up time

01:20 h:min

Standby power input

30.9 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

278 l

AWHPR 8 MR + MIC-2C V190 R32
Configure model
Model name
AWHPR 8 MR + MIC-2C V190 R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.60 kW

8.00 kW

El input

1.74 kW

2.99 kW

COP

4.38

2.68

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.41 kW

1.53 kW

Cooling capacity

6.50

7.10

EER

2.70

4.64

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

6.50 kW

7.10 kW

SEER

3.86

5.04

Pdc Tj = 35°C

6.50 kW

7.10 kW

EER Tj = 35°C

2.70

4.64

Pdc Tj = 30°C

4.97 kW

5.65 kW

EER Tj = 30°C

3.74

6.16

Cdc Tj = 30 °C

 

 

Pdc Tj = 25°C

3.35 kW

3.18 kW

EER Tj = 25°C

4.29

4.68

Cdc Tj = 25 °C

 

 

Pdc Tj = 20°C

1.55 kW

1.67 kW

EER Tj = 20°C

4.34

5.55

Cdc Tj = 20 °C

 

 

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1010 kWh

845 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

116 %

Prated

7.00 kW

7.00 kW

SCOP

4.09

2.99

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.19 kW

6.19 kW

COP Tj = -7°C

2.87

1.90

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.12 kW

3.79 kW

COP Tj = +2°C

4.13

3.04

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.78 kW

2.49 kW

COP Tj = +7°C

4.94

3.65

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

2.67 kW

2.55 kW

COP Tj = 12°C

6.40

5.17

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

6.19 kW

6.19 kW

COP Tj = Tbiv

2.87

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.64 kW

4.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.36 kW

2.10 kW

Annual energy consumption Qhe

3535 kWh

4843 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

186 %

134 %

Prated

7.00 kW

6.60 kW

SCOP

4.72

3.44

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.00 kW

6.60 kW

COP Tj = +2°C

3.14

2.07

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.70 kW

4.58 kW

COP Tj = +7°C

4.72

3.18

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

2.11 kW

2.00 kW

COP Tj = 12°C

5.42

4.21

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

7.00 kW

6.60 kW

COP Tj = Tbiv

3.14

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.14

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1980 kWh

2566 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

108 %

COP

2.50

Heating up time

01:25 h:min

Standby power input

31.9 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

278 l

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

143 %

COP

3.40

Heating up time

01:20 h:min

Standby power input

30.9 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

278 l

AWHPR 6 MR + MIC-1C V190 R32
Configure model
Model name
AWHPR 6 MR + MIC-1C V190 R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.40 kW

5.70 kW

El input

1.28 kW

1.97 kW

COP

5.00

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.30 kW

1.43 kW

Cooling capacity

6.50

7.00

EER

2.83

4.88

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

6.5 kW

7.0 kW

SEER

3.95

5.99

Pdc Tj = 35°C

6.50 kW

7.00 kW

EER Tj = 35°C

2.83

4.88

Pdc Tj = 30°C

4.90 kW

5.39 kW

EER Tj = 30°C

3.99

6.65

Pdc Tj = 25°C

3.10 kW

3.32 kW

EER Tj = 25°C

4.55

4.93

Pdc Tj = 20°C

1.37 kW

1.78 kW

EER Tj = 20°C

3.96

9.48

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

987 kWh

701 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

132 %

Prated

6.50 kW

6.00 kW

SCOP

4.50

3.37

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.50 kW

COP Tj = -7°C

3.16

2.22

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.50 kW

3.40 kW

COP Tj = +2°C

4.48

3.37

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.25 kW

2.10 kW

COP Tj = +7°C

5.61

4.07

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

2.50 kW

2.50 kW

COP Tj = 12°C

6.92

6.58

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

6.60 kW

5.50 kW

COP Tj = Tbiv

2.68

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.60 kW

5.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: PSUP

0 kW

0.7 kW

Annual energy consumption Qhe

2986 kWh

3679 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

207 %

141 %

Prated

6.50 kW

6.00 kW

SCOP

5.24

3.61

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.50 kW

6.00 kW

COP Tj = +2°C

3.40

2.27

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.30 kW

4.05 kW

COP Tj = +7°C

5.30

3.16

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

1.86 kW

1.90 kW

COP Tj = 12°C

6.07

4.70

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

6.50 kW

6.00 kW

COP Tj = Tbiv

3.40

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.50 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.40

2.27

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

1658 kWh

2222 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

135 %

COP

3.20

Heating up time

01:35 h:min

Standby power input

35.5 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

277 l

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

149 %

COP

3.50

Heating up time

01:28 h:min

Standby power input

36.5 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

277 l

AWHPR 6 MR + MIC-2C V190 R32
Configure model
Model name
AWHPR 6 MR + MIC-2C V190 R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.40 kW

5.70 kW

El input

1.36 kW

2.05 kW

COP

4.70

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.38 kW

1.51 kW

Cooling capacity

6.50

7.00

EER

2.74

4.64

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

6.50 kW

7.00 kW

SEER

3.55

5.17

Pdc Tj = 35°C

6.50 kW

7.00 kW

EER Tj = 35°C

2.74

4.64

Pdc Tj = 30°C

4.90 kW

5.39 kW

EER Tj = 30°C

3.76

6.09

Cdc Tj = 30 °C

 

 

Pdc Tj = 25°C

3.10 kW

3.32 kW

EER Tj = 25°C

4.10

4.44

Cdc Tj = 25 °C

 

 

Pdc Tj = 20°C

1.37 kW

1.78 kW

EER Tj = 20°C

3.25

6.77

Cdc Tj = 20 °C

 

 

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1099 kWh

812 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

121 %

Prated

6.50 kW

6.00 kW

SCOP

4.04

3.10

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.50 kW

COP Tj = -7°C

3.04

2.15

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.50 kW

3.40 kW

COP Tj = +2°C

4.09

3.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.25 kW

2.10 kW

COP Tj = +7°C

4.73

3.55

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

2.50 kW

2.50 kW

COP Tj = 12°C

5.73

5.50

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

6.60 kW

5.50 kW

COP Tj = Tbiv

2.60

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.60 kW

5.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.70 kW

Annual energy consumption Qhe

3321 kWh

4004 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

179 %

127 %

Prated

6.50 kW

6.00 kW

SCOP

4.54

3.25

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.50 kW

6.00 kW

COP Tj = +2°C

3.27

2.21

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.30 kW

4.05 kW

COP Tj = +7°C

4.85

2.99

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

1.86 kW

1.90 kW

COP Tj = 12°C

4.88

3.96

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

6.50 kW

6.00 kW

COP Tj = Tbiv

3.27

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.50 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.27

2.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1913 kWh

2466 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

135 %

COP

3.20

Heating up time

01:35 h:min

Standby power input

35.5 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

277 l

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

149 %

COP

3.50

Heating up time

01:28 h:min

Standby power input

36.5 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

277 l

AWHPR 8 MR + MIC-1C V190 R32
Configure model
Model name
AWHPR 8 MR + MIC-1C V190 R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.6 kW

8.0 kW

El input

1.66 kW

2.91 kW

COP

4.57

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.33 kW

1.45 kW

Cooling capacity

6.50

7.10

EER

2.79

4.88

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

6.5 kW

7.1 kW

SEER

4.32

5.82

Pdc Tj = 35°C

6.50 kW

7.10 kW

EER Tj = 35°C

2.79

4.88

Pdc Tj = 30°C

4.97 kW

5.65 kW

EER Tj = 30°C

3.96

6.71

Pdc Tj = 25°C

3.35 kW

3.18 kW

EER Tj = 25°C

4.74

5.26

Pdc Tj = 20°C

1.55 kW

1.67 kW

EER Tj = 20°C

5.50

7.40

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

904 kWh

732 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

125 %

Prated

7.00 kW

7.00 kW

SCOP

4.48

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.19 kW

6.19 kW

COP Tj = -7°C

2.97

1.95

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.12 kW

3.79 kW

COP Tj = +2°C

4.46

3.24

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

2.78 kW

2.49 kW

COP Tj = +7°C

5.70

4.10

Cdh Tj = +7 °C

0.97

0.97

Pdh Tj = 12°C

2.67 kW

2.55 kW

COP Tj = 12°C

7.80

6.10

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

6.19 kW

6.19 kW

COP Tj = Tbiv

2.97

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.64 kW

4.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.58

1.66

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: PSUP

0.36 kW

2.1 kW

Annual energy consumption Qhe

3225 kWh

4504 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

214 %

149 %

Prated

7.00 kW

6.60 kW

SCOP

5.41

3.81

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.00 kW

6.60 kW

COP Tj = +2°C

3.25

2.12

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.70 kW

4.58 kW

COP Tj = +7°C

5.11

3.36

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

2.11 kW

2.00 kW

COP Tj = 12°C

6.71

5.00

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

7.00 kW

6.60 kW

COP Tj = Tbiv

3.25

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.25

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1728 kWh

2315 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.85

Heating up time

01:25 h:min

Standby power input

34.9 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

278 l

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

143 %

COP

3.40

Heating up time

01:20 h:min

Standby power input

30.9 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

278 l

AWHPR 8 MR + MIC-2C V190 R32
Configure model
Model name
AWHPR 8 MR + MIC-2C V190 R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.60 kW

8.00 kW

El input

1.74 kW

2.99 kW

COP

4.38

2.68

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.41 kW

1.53 kW

Cooling capacity

6.50

7.10

EER

2.70

4.64

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

6.50 kW

7.10 kW

SEER

3.86

5.04

Pdc Tj = 35°C

6.50 kW

7.10 kW

EER Tj = 35°C

2.70

4.64

Pdc Tj = 30°C

4.97 kW

5.65 kW

EER Tj = 30°C

3.74

6.16

Cdc Tj = 30 °C

 

 

Pdc Tj = 25°C

3.35 kW

3.18 kW

EER Tj = 25°C

4.29

4.68

Cdc Tj = 25 °C

 

 

Pdc Tj = 20°C

1.55 kW

1.67 kW

EER Tj = 20°C

4.34

5.55

Cdc Tj = 20 °C

 

 

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1010 kWh

845 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

116 %

Prated

7.00 kW

7.00 kW

SCOP

4.09

2.99

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.19 kW

6.19 kW

COP Tj = -7°C

2.87

1.90

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.12 kW

3.79 kW

COP Tj = +2°C

4.13

3.04

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.78 kW

2.49 kW

COP Tj = +7°C

4.94

3.65

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

2.67 kW

2.55 kW

COP Tj = 12°C

6.40

5.17

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

6.19 kW

6.19 kW

COP Tj = Tbiv

2.87

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.64 kW

4.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.36 kW

2.10 kW

Annual energy consumption Qhe

3535 kWh

4843 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

186 %

134 %

Prated

7.00 kW

6.60 kW

SCOP

4.72

3.44

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.00 kW

6.60 kW

COP Tj = +2°C

3.14

2.07

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.70 kW

4.58 kW

COP Tj = +7°C

4.72

3.18

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

2.11 kW

2.00 kW

COP Tj = 12°C

5.42

4.21

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

7.00 kW

6.60 kW

COP Tj = Tbiv

3.14

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.14

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1980 kWh

2566 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.85

Heating up time

01:25 h:min

Standby power input

34.9 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

278 l

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

143 %

COP

3.40

Heating up time

01:20 h:min

Standby power input

30.9 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

278 l