Certificate holders

Subtype

DAIKIN ALTHERMA 3 H MT F+W 10KW (180L)

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0507
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA 3 H MT F+W 10KW (180L)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

3,250 kg

Certification Date
24.11.2021
Testing basis
HP KEYMARK certification scheme rules rev. 9
Generate PDF Export model CSV
  • Number of models 18

Models

EPRA10EV3 / ETBH12E(6V/9W)
Configure model
Model name
EPRA10EV3 / ETBH12E(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.66 kW

Cooling capacity

7.97

EER

3.00

EN 14825

+7°C/+12°C

Pdesignc

7.5 kW

SEER

5.34

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.00

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.28

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.31

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.37

Cdc Tj = 20 °C

0.91

Poff

99 W

PTO

99 W

PSB

99 W

PCK

99 W

Annual energy consumption Qce

843 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

134 %

Prated

8.3 kW

8.5 kW

SCOP

4.71

3.43

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.77

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.97

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3637 kWh

5120 kWh

EPRA10EV3 / ETBX12E(6V/9W)
Configure model
Model name
EPRA10EV3 / ETBX12E(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.66 kW

Cooling capacity

7.97

EER

3.00

EN 14825

+7°C/+12°C

Pdesignc

7.50 kW

SEER

5.34

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.00

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.28

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.31

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.37

Cdc Tj = 20 °C

0.910

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

843 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

136 %

Prated

8.3 kW

8.5 kW

SCOP

4.82

3.48

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.77

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.97

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3560 kWh

5043 kWh

EPRA10EV3 / ETVH12S18E(6V/9W)
Configure model
Model name
EPRA10EV3 / ETVH12S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.66 kW

Cooling capacity

7.97

EER

3.00

EN 14825

+7°C/+12°C

Pdesignc

7.5 kW

SEER

5.34

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.00

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.28

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.31

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.37

Cdc Tj = 20 °C

0.91

Poff

99 W

PTO

99 W

PSB

99 W

PCK

99 W

Annual energy consumption Qce

843 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

134 %

Prated

8.3 kW

8.5 kW

SCOP

4.71

3.43

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.77

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.97

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3637 kWh

5120 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.72

Heating up time

1:57 h:min

Standby power input

51.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA10EV3 / ETVH12SU18E6V
Configure model
Model name
EPRA10EV3 / ETVH12SU18E6V
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.66 kW

Cooling capacity

7.97

EER

3.00

EN 14825

+7°C/+12°C

Pdesignc

7.5 kW

SEER

5.34

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.00

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.28

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.31

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.37

Cdc Tj = 20 °C

0.91

Poff

99 W

PTO

99 W

PSB

99 W

PCK

99 W

Annual energy consumption Qce

843 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

134 %

Prated

8.3 kW

8.5 kW

SCOP

4.71

3.43

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.77

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.97

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3637 kWh

5120 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.72

Heating up time

1:57 h:min

Standby power input

51.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA10EV3 / ETVX12S18E(6V/9W)
Configure model
Model name
EPRA10EV3 / ETVX12S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.66 kW

Cooling capacity

7.97

EER

3.00

EN 14825

+7°C/+12°C

Pdesignc

7.50 kW

SEER

5.34

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.00

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.28

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.31

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.37

Cdc Tj = 20 °C

0.910

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

843 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

136 %

Prated

8.3 kW

8.5 kW

SCOP

4.82

3.48

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.77

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.97

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3560 kWh

5043 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.72

Heating up time

1:57 h:min

Standby power input

51.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA10EV3 / ETVZ12S18E(6V/9W)
Configure model
Model name
EPRA10EV3 / ETVZ12S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.66 kW

Cooling capacity

7.97

EER

3.00

EN 14825

+7°C/+12°C

Pdesignc

7.5 kW

SEER

5.34

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.00

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.28

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.31

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.37

Cdc Tj = 20 °C

0.91

Poff

99 W

PTO

99 W

PSB

99 W

PCK

99 W

Annual energy consumption Qce

843 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

134 %

Prated

8.3 kW

8.5 kW

SCOP

4.71

3.43

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.77

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.97

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3637 kWh

5120 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.72

Heating up time

1:57 h:min

Standby power input

51.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA10EW1 / ETBH12E(6V/9W)
Configure model
Model name
EPRA10EW1 / ETBH12E(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.57 kW

Cooling capacity

7.97

EER

3.10

EN 14825

+7°C/+12°C

Pdesignc

7.5 kW

SEER

5.41

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.10

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.43

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.47

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.35

Cdc Tj = 20 °C

0.91

Poff

99 W

PTO

99 W

PSB

99 W

PCK

99 W

Annual energy consumption Qce

831 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

138 %

Prated

8.3 kW

8.5 kW

SCOP

4.84

3.53

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.86

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.05

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3539 kWh

4970 kWh

EPRA10EW1 / ETBX12E(6V/9W)
Configure model
Model name
EPRA10EW1 / ETBX12E(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.57 kW

Cooling capacity

7.97

EER

3.10

EN 14825

+7°C/+12°C

Pdesignc

7.50 kW

SEER

5.41

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.10

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.43

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.47

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.35

Cdc Tj = 20 °C

0.910

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

831 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

141 %

Prated

8.3 kW

8.5 kW

SCOP

4.98

3.60

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.86

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.05

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3440 kWh

4871 kWh

EPRA10EW1 / ETVH12S18E(6V/9W)
Configure model
Model name
EPRA10EW1 / ETVH12S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.57 kW

Cooling capacity

7.97

EER

3.10

EN 14825

+7°C/+12°C

Pdesignc

7.5 kW

SEER

5.41

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.10

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.43

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.47

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.35

Cdc Tj = 20 °C

0.91

Poff

99 W

PTO

99 W

PSB

99 W

PCK

99 W

Annual energy consumption Qce

831 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

138 %

Prated

8.3 kW

8.5 kW

SCOP

4.84

3.53

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.86

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.05

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3539 kWh

4970 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.80

Heating up time

1:57 h:min

Standby power input

50.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA10EW1 / ETVH12SU18E6V
Configure model
Model name
EPRA10EW1 / ETVH12SU18E6V
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.57 kW

Cooling capacity

7.97

EER

3.10

EN 14825

+7°C/+12°C

Pdesignc

7.5 kW

SEER

5.41

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.10

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.43

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.47

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.35

Cdc Tj = 20 °C

0.91

Poff

99 W

PTO

99 W

PSB

99 W

PCK

99 W

Annual energy consumption Qce

831 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

138 %

Prated

8.3 kW

8.5 kW

SCOP

4.84

3.53

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.86

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.05

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3539 kWh

4970 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.80

Heating up time

1:57 h:min

Standby power input

50.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA10EW1 / ETVX12S18E(6V/9W)
Configure model
Model name
EPRA10EW1 / ETVX12S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.57 kW

Cooling capacity

7.97

EER

3.10

EN 14825

+7°C/+12°C

Pdesignc

7.50 kW

SEER

5.41

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.10

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.43

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.47

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.35

Cdc Tj = 20 °C

0.910

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

831 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

141 %

Prated

8.3 kW

8.5 kW

SCOP

4.98

3.60

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.86

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.05

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3440 kWh

4871 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.80

Heating up time

1:57 h:min

Standby power input

50.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA10EW1 / ETVZ12S18E(6V/9W)
Configure model
Model name
EPRA10EW1 / ETVZ12S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.57 kW

Cooling capacity

7.97

EER

3.10

EN 14825

+7°C/+12°C

Pdesignc

7.5 kW

SEER

5.41

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.10

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.43

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.47

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.35

Cdc Tj = 20 °C

0.91

Poff

99 W

PTO

99 W

PSB

99 W

PCK

99 W

Annual energy consumption Qce

831 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

138 %

Prated

8.3 kW

8.5 kW

SCOP

4.84

3.53

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.86

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.05

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3539 kWh

4970 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.80

Heating up time

1:57 h:min

Standby power input

50.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA10EV3 / ETBH12E(6V/9W) + cooling kit
Configure model
Model name
EPRA10EV3 / ETBH12E(6V/9W) + cooling kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.66 kW

Cooling capacity

7.97

EER

3.00

EN 14825

+7°C/+12°C

Pdesignc

7.50 kW

SEER

5.34

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.00

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.28

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.31

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.37

Cdc Tj = 20 °C

0.910

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

843 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

136 %

Prated

8.3 kW

8.5 kW

SCOP

4.82

3.48

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.77

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.97

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3560 kWh

5043 kWh

EPRA10EV3 / ETVH12S18E(6V/9W) + cooling kit
Configure model
Model name
EPRA10EV3 / ETVH12S18E(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.66 kW

Cooling capacity

7.97

EER

3.00

EN 14825

+7°C/+12°C

Pdesignc

7.50 kW

SEER

5.34

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.00

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.28

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.31

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.37

Cdc Tj = 20 °C

0.910

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

843 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

136 %

Prated

8.3 kW

8.5 kW

SCOP

4.82

3.48

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.77

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.97

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3560 kWh

5043 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.72

Heating up time

1:57 h:min

Standby power input

51.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA10EW1 / ETBH12E(6V/9W) + cooling kit
Configure model
Model name
EPRA10EW1 / ETBH12E(6V/9W) + cooling kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.57 kW

Cooling capacity

7.97

EER

3.10

EN 14825

+7°C/+12°C

Pdesignc

7.50 kW

SEER

5.41

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.10

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.43

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.47

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.35

Cdc Tj = 20 °C

0.910

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

831 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

141 %

Prated

8.3 kW

8.5 kW

SCOP

4.98

3.60

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.86

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.05

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3440 kWh

4871 kWh

EPRA10EW1 / ETVH12S18E(6V/9W) + cooling kit
Configure model
Model name
EPRA10EW1 / ETVH12S18E(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.57 kW

Cooling capacity

7.97

EER

3.10

EN 14825

+7°C/+12°C

Pdesignc

7.50 kW

SEER

5.41

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.10

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.43

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.47

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.35

Cdc Tj = 20 °C

0.910

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

831 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

141 %

Prated

8.3 kW

8.5 kW

SCOP

4.98

3.60

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.86

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.05

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3440 kWh

4871 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.80

Heating up time

1:57 h:min

Standby power input

50.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA10EV3 / ETVZ12S18E(6V/9W) + cooling kit
Configure model
Model name
EPRA10EV3 / ETVZ12S18E(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.66 kW

Cooling capacity

7.97

EER

3.00

EN 14825

+7°C/+12°C

Pdesignc

7.50 kW

SEER

5.34

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.00

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.28

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.31

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.37

Cdc Tj = 20 °C

0.910

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

843 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

136 %

Prated

8.3 kW

8.5 kW

SCOP

4.82

3.48

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.77

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.97

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3560 kWh

5043 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.72

Heating up time

1:57 h:min

Standby power input

51.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA10EW1 / ETVZ12S18E(6V/9W) + cooling kit
Configure model
Model name
EPRA10EW1 / ETVZ12S18E(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.57 kW

Cooling capacity

7.97

EER

3.10

EN 14825

+7°C/+12°C

Pdesignc

7.50 kW

SEER

5.41

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.10

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.43

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.47

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.35

Cdc Tj = 20 °C

0.910

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

831 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

141 %

Prated

8.3 kW

8.5 kW

SCOP

4.98

3.60

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.1 kW

8.3 kW

COP Tj = Tbiv

2.86

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.3 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.05

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.0 kW

0.0 kW

Annual energy consumption Qhe

3440 kWh

4871 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.80

Heating up time

1:57 h:min

Standby power input

50.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l