1,100 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.99 kW
5.13 kW
El input
1.21 kW
1.87 kW
COP
4.97
2.74
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
130 %
Prated
5.29 kW
5.00 kW
SCOP
4.75
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.68 kW
5.00 kW
COP Tj = -7°C
3.28
2.20
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.86 kW
3.09 kW
COP Tj = +2°C
4.52
3.26
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.45 kW
2.73 kW
COP Tj = +7°C
5.87
4.03
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
2.85 kW
2.70 kW
COP Tj = 12°C
8.72
6.34
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
4.68 kW
5.00 kW
COP Tj = Tbiv
3.28
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.92 kW
4.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.79
1.71
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
53 °C
53 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
43 W
43 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.38 kW
1.32 kW
Annual energy consumption Qhe
2302 kWh
3503 kWh