1,650 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.30 kW
7.50 kW
El input
1.60 kW
2.36 kW
COP
5.20
3.18
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
273 %
176 %
Prated
8.12 kW
7.56 kW
SCOP
6.99
4.47
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.57 kW
7.55 kW
COP Tj = +2°C
3.98
2.59
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.22 kW
4.86 kW
COP Tj = +7°C
6.26
3.92
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.45 kW
2.32 kW
COP Tj = 12°C
9.02
5.55
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.22 kW
4.86 kW
COP Tj = Tbiv
6.26
3.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.57 kW
7.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.98
2.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.55 kW
0.01 kW
Annual energy consumption Qhe
1569 kWh
2259 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
112 %
Prated
6.98 kW
5.78 kW
SCOP
4.32
2.88
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.46 kW
3.86 kW
COP Tj = -7°C
3.66
2.48
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
2.70 kW
2.21 kW
COP Tj = +2°C
5.20
3.35
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
1.66 kW
1.44 kW
COP Tj = +7°C
6.53
4.11
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.66 kW
1.47 kW
COP Tj = 12°C
7.96
5.92
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.69 kW
4.71 kW
COP Tj = Tbiv
2.83
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.06 kW
2.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.95
1.22
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.91 kW
2.99 kW
Annual energy consumption Qhe
3978 kWh
4950 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.69
4.71
COP Tj = -15°C (if TOL<-20°C)
2.83
1.90
Cdh Tj = -15 °C
0.90
0.90
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
132 %
Prated
8.12 kW
6.60 kW
SCOP
5.21
3.36
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.19 kW
5.84 kW
COP Tj = -7°C
3.35
2.16
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
4.65 kW
3.76 kW
COP Tj = +2°C
5.09
3.30
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.90 kW
2.43 kW
COP Tj = +7°C
6.82
4.34
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.63 kW
1.40 kW
COP Tj = 12°C
8.35
5.33
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
7.19 kW
5.84 kW
COP Tj = Tbiv
3.35
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.45 kW
4.91 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
1.84
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.68 kW
1.69 kW
Annual energy consumption Qhe
3223 kWh
4056 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.00 kW
9.50 kW
El input
2.00 kW
3.06 kW
COP
5.00
3.10
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
279 %
180 %
Prated
8.58 kW
8.63 kW
SCOP
7.12
4.58
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.44 kW
8.06 kW
COP Tj = +2°C
3.84
2.59
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.52 kW
5.55 kW
COP Tj = +7°C
6.18
4.10
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.62 kW
2.53 kW
COP Tj = 12°C
9.04
5.82
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.52 kW
5.55 kW
COP Tj = Tbiv
6.18
4.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.44 kW
8.16 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.84
2.61
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.14 kW
0.48 kW
Annual energy consumption Qhe
1628 kWh
2516 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
116 %
Prated
7.75 kW
6.71 kW
SCOP
4.32
2.99
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.83 kW
4.27 kW
COP Tj = -7°C
3.60
2.54
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
2.94 kW
2.57 kW
COP Tj = +2°C
5.26
3.51
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
1.92 kW
1.66 kW
COP Tj = +7°C
7.08
4.37
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.66 kW
1.48 kW
COP Tj = 12°C
7.96
5.96
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
6.32 kW
5.48 kW
COP Tj = Tbiv
2.64
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.63 kW
2.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.97
1.22
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.13 kW
3.91 kW
Annual energy consumption Qhe
4424 kWh
5540 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.32
5.48
COP Tj = -15°C (if TOL<-20°C)
2.64
2.00
Cdh Tj = -15 °C
0.90
0.90
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
137 %
Prated
9.17 kW
7.67 kW
SCOP
5.19
3.49
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.11 kW
6.78 kW
COP Tj = -7°C
3.23
2.24
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
5.18 kW
4.29 kW
COP Tj = +2°C
5.01
3.42
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
3.32 kW
2.77 kW
COP Tj = +7°C
7.08
4.52
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.65 kW
1.58 kW
COP Tj = 12°C
8.58
5.68
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
8.11 kW
6.78 kW
COP Tj = Tbiv
3.23
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.40 kW
5.39 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.96
1.83
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.76 kW
2.28 kW
Annual energy consumption Qhe
3647 kWh
4539 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.40 kW
7.50 kW
El input
1.63 kW
2.36 kW
COP
5.15
3.18
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
273 %
176 %
Prated
8.12 kW
7.56 kW
SCOP
6.99
4.47
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.57 kW
7.55 kW
COP Tj = +2°C
3.98
2.59
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.22 kW
4.86 kW
COP Tj = +7°C
6.26
3.92
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.45 kW
2.32 kW
COP Tj = 12°C
9.02
5.55
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.22 kW
4.86 kW
COP Tj = Tbiv
6.26
3.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.57 kW
7.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.98
2.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.55 kW
0.01 kW
Annual energy consumption Qhe
1569 kWh
2259 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
112 %
Prated
6.98 kW
5.78 kW
SCOP
4.32
2.88
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.46 kW
3.86 kW
COP Tj = -7°C
3.66
2.48
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
2.70 kW
2.21 kW
COP Tj = +2°C
5.20
3.35
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
1.66 kW
1.44 kW
COP Tj = +7°C
6.53
4.11
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.66 kW
1.47 kW
COP Tj = 12°C
7.96
5.92
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.69 kW
4.71 kW
COP Tj = Tbiv
2.83
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.06 kW
2.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.95
1.22
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.91 kW
2.99 kW
Annual energy consumption Qhe
3978 kWh
4950 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.69
4.71
COP Tj = -15°C (if TOL<-20°C)
2.83
1.90
Cdh Tj = -15 °C
0.90
0.90
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
132 %
Prated
8.12 kW
6.60 kW
SCOP
5.21
3.36
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.19 kW
5.84 kW
COP Tj = -7°C
3.35
2.16
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
4.65 kW
3.76 kW
COP Tj = +2°C
5.09
3.30
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.90 kW
2.43 kW
COP Tj = +7°C
6.82
4.34
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.63 kW
1.40 kW
COP Tj = 12°C
8.35
5.33
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
7.19 kW
5.84 kW
COP Tj = Tbiv
3.35
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.45 kW
4.91 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
1.84
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.68 kW
1.69 kW
Annual energy consumption Qhe
3223 kWh
4056 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.00 kW
9.50 kW
El input
2.02 kW
3.06 kW
COP
4.95
3.10
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
279 %
180 %
Prated
8.58 kW
8.63 kW
SCOP
7.12
4.58
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.44 kW
8.06 kW
COP Tj = +2°C
3.84
2.59
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.52 kW
5.55 kW
COP Tj = +7°C
6.18
4.10
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.62 kW
2.53 kW
COP Tj = 12°C
9.04
5.82
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.52 kW
5.55 kW
COP Tj = Tbiv
6.18
4.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.44 kW
8.16 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.84
2.61
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.14 kW
0.48 kW
Annual energy consumption Qhe
1628 kWh
2516 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
116 %
Prated
7.75 kW
6.71 kW
SCOP
4.32
2.99
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.83 kW
4.27 kW
COP Tj = -7°C
3.60
2.54
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
2.94 kW
2.57 kW
COP Tj = +2°C
5.26
3.51
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
1.92 kW
1.66 kW
COP Tj = +7°C
7.08
4.37
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.66 kW
1.48 kW
COP Tj = 12°C
7.96
5.96
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
6.32 kW
5.48 kW
COP Tj = Tbiv
2.64
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.63 kW
2.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.97
1.22
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.13 kW
3.91 kW
Annual energy consumption Qhe
4424 kWh
5540 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.32
5.48
COP Tj = -15°C (if TOL<-20°C)
2.64
2.00
Cdh Tj = -15 °C
0.90
0.90
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
137 %
Prated
9.17 kW
7.67 kW
SCOP
5.19
3.49
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.11 kW
6.78 kW
COP Tj = -7°C
3.23
2.24
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
5.18 kW
4.29 kW
COP Tj = +2°C
5.01
3.42
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
3.32 kW
2.77 kW
COP Tj = +7°C
7.08
4.52
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.65 kW
1.58 kW
COP Tj = 12°C
8.58
5.68
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
8.11 kW
6.78 kW
COP Tj = Tbiv
3.23
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.40 kW
5.39 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.96
1.83
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.76 kW
2.28 kW
Annual energy consumption Qhe
3647 kWh
4539 kWh