Certificate holders

Subtype

Sherpa S2 E 8/10

Certificate Holder
Olimpia Splendid S.p.A.
Via Industriale, 1/3
25060 Cellatica (BS)
Italy
Registration number
ICIM-PDC-000131-00
Certification Body
ICIM S.p.A.
Subtype title
Sherpa S2 E 8/10
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

3,900 kg

Certification Date
10.12.2021
Testing basis
Heat Pump KEYMARK rev9
Phase-out Date
30.10.2025
Generate PDF Export model CSV Download certificate
  • Number of models 8

Models

Sherpa S2 E 8 Phasing out on 30.10.2025
Configure model
Model name
Sherpa S2 E 8
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
30.10.2025

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.40 kW

5.15 kW

El input

1.73 kW

2.23 kW

COP

4.85

2.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

128 %

Prated

8.88 kW

7.92 kW

SCOP

4.78

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.85 kW

7.01 kW

COP Tj = -7°C

2.96

2.02

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.20 kW

4.46 kW

COP Tj = +2°C

4.55

3.19

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.33 kW

2.95 kW

COP Tj = +7°C

6.58

4.41

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.08 kW

1.38 kW

COP Tj = 12°C

8.66

5.11

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.85 kW

7.01 kW

COP Tj = Tbiv

2.96

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.45 kW

6.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

14 W

14 W

PTO

29 W

29 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.43 kW

1.30 kW

Annual energy consumption Qhe

3837 kWh

4988 kWh

Sherpa S2 E 10 Phasing out on 30.10.2025
Configure model
Model name
Sherpa S2 E 10
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
30.10.2025

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

8.95 kW

El input

2.15 kW

3.30 kW

COP

4.65

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

128 %

Prated

8.88 kW

7.92 kW

SCOP

4.78

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.85 kW

7.01 kW

COP Tj = -7°C

2.96

2.02

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.20 kW

4.46 kW

COP Tj = +2°C

4.55

3.19

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.33 kW

2.95 kW

COP Tj = +7°C

6.58

4.41

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.08 kW

1.38 kW

COP Tj = 12°C

8.66

5.11

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.85 kW

7.01 kW

COP Tj = Tbiv

2.96

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.45 kW

6.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

14 W

14 W

PTO

29 W

29 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.43 kW

1.30 kW

Annual energy consumption Qhe

3837 kWh

4988 kWh

Sherpa Aquadue S2 E 8 Phasing out on 30.10.2025
Configure model
Model name
Sherpa Aquadue S2 E 8
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
30.10.2025

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.40 kW

5.15 kW

El input

1.73 kW

2.23 kW

COP

4.85

2.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

128 %

Prated

8.88 kW

7.92 kW

SCOP

4.78

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.85 kW

7.01 kW

COP Tj = -7°C

2.96

2.02

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.20 kW

4.46 kW

COP Tj = +2°C

4.55

3.19

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.33 kW

2.95 kW

COP Tj = +7°C

6.58

4.41

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.08 kW

1.38 kW

COP Tj = 12°C

8.66

5.11

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.85 kW

7.01 kW

COP Tj = Tbiv

2.96

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.45 kW

6.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

14 W

14 W

PTO

29 W

29 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.43 kW

1.30 kW

Annual energy consumption Qhe

3837 kWh

4988 kWh

Sherpa Aquadue S2 E 10 Phasing out on 30.10.2025
Configure model
Model name
Sherpa Aquadue S2 E 10
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
30.10.2025

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

8.95 kW

El input

2.15 kW

3.30 kW

COP

4.65

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

128 %

Prated

8.88 kW

7.92 kW

SCOP

4.78

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.85 kW

7.01 kW

COP Tj = -7°C

2.96

2.02

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.20 kW

4.46 kW

COP Tj = +2°C

4.55

3.19

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.33 kW

2.95 kW

COP Tj = +7°C

6.58

4.41

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.08 kW

1.38 kW

COP Tj = 12°C

8.66

5.11

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.85 kW

7.01 kW

COP Tj = Tbiv

2.96

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.45 kW

6.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

14 W

14 W

PTO

29 W

29 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.43 kW

1.30 kW

Annual energy consumption Qhe

3837 kWh

4988 kWh

Sherpa Tower S2 E 8 Phasing out on 30.10.2025
Configure model
Model name
Sherpa Tower S2 E 8
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
30.10.2025

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.40 kW

5.15 kW

El input

1.73 kW

2.23 kW

COP

4.85

2.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

128 %

Prated

8.88 kW

7.92 kW

SCOP

4.78

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.85 kW

7.01 kW

COP Tj = -7°C

2.96

2.02

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.20 kW

4.46 kW

COP Tj = +2°C

4.55

3.19

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.33 kW

2.95 kW

COP Tj = +7°C

6.58

4.41

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.08 kW

1.38 kW

COP Tj = 12°C

8.66

5.11

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.85 kW

7.01 kW

COP Tj = Tbiv

2.96

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.45 kW

6.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

14 W

14 W

PTO

29 W

29 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.43 kW

1.30 kW

Annual energy consumption Qhe

3837 kWh

4988 kWh

Sherpa Tower S2 E 10 Phasing out on 30.10.2025
Configure model
Model name
Sherpa Tower S2 E 10
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
30.10.2025

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

8.95 kW

El input

2.15 kW

3.30 kW

COP

4.65

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

128 %

Prated

8.88 kW

7.92 kW

SCOP

4.78

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.85 kW

7.01 kW

COP Tj = -7°C

2.96

2.02

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.20 kW

4.46 kW

COP Tj = +2°C

4.55

3.19

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.33 kW

2.95 kW

COP Tj = +7°C

6.58

4.41

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.08 kW

1.38 kW

COP Tj = 12°C

8.66

5.11

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.85 kW

7.01 kW

COP Tj = Tbiv

2.96

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.45 kW

6.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

14 W

14 W

PTO

29 W

29 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.43 kW

1.30 kW

Annual energy consumption Qhe

3837 kWh

4988 kWh

Sherpa Aquadue Tower S2 E 8 Phasing out on 30.10.2025
Configure model
Model name
Sherpa Aquadue Tower S2 E 8
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
30.10.2025

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.40 kW

5.15 kW

El input

1.73 kW

2.23 kW

COP

4.85

2.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

128 %

Prated

8.88 kW

7.92 kW

SCOP

4.78

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.85 kW

7.01 kW

COP Tj = -7°C

2.96

2.02

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.20 kW

4.46 kW

COP Tj = +2°C

4.55

3.19

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.33 kW

2.95 kW

COP Tj = +7°C

6.58

4.41

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.08 kW

1.38 kW

COP Tj = 12°C

8.66

5.11

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.85 kW

7.01 kW

COP Tj = Tbiv

2.96

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.45 kW

6.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

14 W

14 W

PTO

29 W

29 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.43 kW

1.30 kW

Annual energy consumption Qhe

3837 kWh

4988 kWh

Sherpa Aquadue Tower S2 E 10 Phasing out on 30.10.2025
Configure model
Model name
Sherpa Aquadue Tower S2 E 10
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
30.10.2025

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

8.95 kW

El input

2.15 kW

3.30 kW

COP

4.65

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

128 %

Prated

8.88 kW

7.92 kW

SCOP

4.78

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.85 kW

7.01 kW

COP Tj = -7°C

2.96

2.02

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.20 kW

4.46 kW

COP Tj = +2°C

4.55

3.19

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.33 kW

2.95 kW

COP Tj = +7°C

6.58

4.41

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.08 kW

1.38 kW

COP Tj = 12°C

8.66

5.11

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.85 kW

7.01 kW

COP Tj = Tbiv

2.96

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.45 kW

6.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

14 W

14 W

PTO

29 W

29 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.43 kW

1.30 kW

Annual energy consumption Qhe

3837 kWh

4988 kWh