1,600 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
6.80 kW
El input
1.96 kW
2.99 kW
COP
1.77
2.27
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
149 %
Prated
6.17 kW
4.95 kW
SCOP
5.46
3.81
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.17 kW
4.94 kW
COP Tj = +2°C
3.53
2.07
Cdh Tj = +2 °C
0.990
0.993
Pdh Tj = +7°C
3.96 kW
3.16 kW
COP Tj = +7°C
5.11
3.36
Cdh Tj = +7 °C
0.978
0.982
Pdh Tj = 12°C
3.99 kW
3.73 kW
COP Tj = 12°C
6.59
4.99
Cdh Tj = +12 °C
0.972
0.977
Pdh Tj = Tbiv
6.17 kW
4.94 kW
COP Tj = Tbiv
3.53
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.17 kW
4.94 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1510 kWh
1737 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
145 %
106 %
Prated
6.74 kW
5.44 kW
SCOP
3.69
2.72
Tbiv
-15 °C
-15 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
4.08 kW
3.27 kW
COP Tj = -7°C
3.44
2.28
Cdh Tj = -7 °C
0.986
0.988
Pdh Tj = +2°C
3.08 kW
2.81 kW
COP Tj = +2°C
4.79
3.40
Cdh Tj = +2 °C
0.974
0.979
Pdh Tj = +7°C
3.51 kW
3.29 kW
COP Tj = +7°C
5.72
4.35
Cdh Tj = +7 °C
0.972
0.978
Pdh Tj = 12°C
4.01 kW
3.83 kW
COP Tj = 12°C
6.62
5.61
Cdh Tj = +12 °C
0.972
0.975
Pdh Tj = Tbiv
5.50 kW
4.44 kW
COP Tj = Tbiv
2.81
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.50 kW
4.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
1.99
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.991
0.992
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.74 kW
5.44 kW
Annual energy consumption Qhe
4500 kWh
4933 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.50
4.43
COP Tj = -15°C (if TOL<-20°C)
2.81
1.99
Cdh Tj = -15 °C
0.991
0.992
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
122 %
Prated
5.84 kW
4.78 kW
SCOP
4.46
3.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.19 kW
4.20 kW
COP Tj = -7°C
3.04
1.91
Cdh Tj = -7 °C
0.990
0.992
Pdh Tj = +2°C
3.01 kW
2.52 kW
COP Tj = +2°C
4.53
3.09
Cdh Tj = +2 °C
0.974
0.979
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.57
4.08
Cdh Tj = +7 °C
0.973
0.978
Pdh Tj = 12°C
3.49 kW
3.81 kW
COP Tj = 12°C
5.57
5.35
Cdh Tj = +12 °C
0.973
0.976
Pdh Tj = Tbiv
5.84 kW
4.77 kW
COP Tj = Tbiv
2.68
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.84 kW
4.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2708 kWh
3163 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
6.80 kW
El input
1.96 kW
2.99 kW
COP
1.77
2.27
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
149 %
Prated
6.17 kW
4.95 kW
SCOP
5.46
3.81
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.17 kW
4.94 kW
COP Tj = +2°C
3.53
2.07
Cdh Tj = +2 °C
0.990
0.993
Pdh Tj = +7°C
3.96 kW
3.16 kW
COP Tj = +7°C
5.11
3.36
Cdh Tj = +7 °C
0.978
0.982
Pdh Tj = 12°C
3.99 kW
3.73 kW
COP Tj = 12°C
6.59
4.99
Cdh Tj = +12 °C
0.972
0.977
Pdh Tj = Tbiv
6.17 kW
4.94 kW
COP Tj = Tbiv
3.53
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.17 kW
4.94 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1510 kWh
1737 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
145 %
106 %
Prated
6.74 kW
5.44 kW
SCOP
3.69
2.72
Tbiv
-15 °C
-15 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
4.08 kW
3.27 kW
COP Tj = -7°C
3.44
2.28
Cdh Tj = -7 °C
0.986
0.988
Pdh Tj = +2°C
3.08 kW
2.81 kW
COP Tj = +2°C
4.79
3.40
Cdh Tj = +2 °C
0.974
0.979
Pdh Tj = +7°C
3.51 kW
3.29 kW
COP Tj = +7°C
5.72
4.35
Cdh Tj = +7 °C
0.972
0.978
Pdh Tj = 12°C
4.01 kW
3.83 kW
COP Tj = 12°C
6.62
5.61
Cdh Tj = +12 °C
0.972
0.975
Pdh Tj = Tbiv
5.50 kW
4.44 kW
COP Tj = Tbiv
2.81
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.50 kW
4.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
1.99
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.991
0.992
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4500 kWh
4933 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.50
4.43
COP Tj = -15°C (if TOL<-20°C)
2.81
1.99
Cdh Tj = -15 °C
0.991
0.992
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
122 %
Prated
5.84 kW
4.78 kW
SCOP
4.46
3.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.19 kW
4.20 kW
COP Tj = -7°C
3.04
1.91
Cdh Tj = -7 °C
0.990
0.992
Pdh Tj = +2°C
3.01 kW
2.52 kW
COP Tj = +2°C
4.53
3.09
Cdh Tj = +2 °C
0.974
0.979
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.57
4.08
Cdh Tj = +7 °C
0.973
0.978
Pdh Tj = 12°C
3.49 kW
3.81 kW
COP Tj = 12°C
5.57
5.35
Cdh Tj = +12 °C
0.973
0.976
Pdh Tj = Tbiv
5.84 kW
4.77 kW
COP Tj = Tbiv
2.68
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.84 kW
4.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2708 kWh
3163 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
6.80 kW
El input
1.96 kW
2.99 kW
COP
1.77
2.27
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
149 %
Prated
6.17 kW
4.95 kW
SCOP
5.46
3.81
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.17 kW
4.94 kW
COP Tj = +2°C
3.53
2.07
Cdh Tj = +2 °C
0.990
0.993
Pdh Tj = +7°C
3.96 kW
3.16 kW
COP Tj = +7°C
5.11
3.36
Cdh Tj = +7 °C
0.978
0.982
Pdh Tj = 12°C
3.99 kW
3.73 kW
COP Tj = 12°C
6.59
4.99
Cdh Tj = +12 °C
0.972
0.977
Pdh Tj = Tbiv
6.17 kW
4.94 kW
COP Tj = Tbiv
3.53
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.17 kW
4.94 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1510 kWh
1737 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
145 %
106 %
Prated
6.74 kW
5.44 kW
SCOP
3.69
2.72
Tbiv
-15 °C
-15 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
4.08 kW
3.27 kW
COP Tj = -7°C
3.44
2.28
Cdh Tj = -7 °C
0.986
0.988
Pdh Tj = +2°C
3.08 kW
2.81 kW
COP Tj = +2°C
4.79
3.40
Cdh Tj = +2 °C
0.974
0.979
Pdh Tj = +7°C
3.51 kW
3.29 kW
COP Tj = +7°C
5.72
4.35
Cdh Tj = +7 °C
0.972
0.978
Pdh Tj = 12°C
4.01 kW
3.83 kW
COP Tj = 12°C
6.62
5.61
Cdh Tj = +12 °C
0.972
0.975
Pdh Tj = Tbiv
5.50 kW
4.44 kW
COP Tj = Tbiv
2.81
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.50 kW
4.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
1.99
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.991
0.992
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.74 kW
5.44 kW
Annual energy consumption Qhe
4500 kWh
4933 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.50
1.99
COP Tj = -15°C (if TOL<-20°C)
2.81
1.99
Cdh Tj = -15 °C
0.991
0.992
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
122 %
Prated
5.84 kW
4.78 kW
SCOP
4.46
3.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.19 kW
4.20 kW
COP Tj = -7°C
3.04
1.91
Cdh Tj = -7 °C
0.990
0.992
Pdh Tj = +2°C
3.01 kW
2.52 kW
COP Tj = +2°C
4.53
3.09
Cdh Tj = +2 °C
0.974
0.979
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.57
4.08
Cdh Tj = +7 °C
0.973
0.978
Pdh Tj = 12°C
3.49 kW
3.81 kW
COP Tj = 12°C
5.57
5.35
Cdh Tj = +12 °C
0.973
0.976
Pdh Tj = Tbiv
5.84 kW
4.77 kW
COP Tj = Tbiv
2.68
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.84 kW
4.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2708 kWh
3163 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
113 %
COP
2.65
Heating up time
01:44 h:min
Standby power input
51.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
252 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
72 %
COP
1.64
Heating up time
02:43 h:min
Standby power input
109.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
250 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
94 %
COP
2.22
Heating up time
02:11 h:min
Standby power input
58.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
254 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
6.80 kW
El input
1.96 kW
2.99 kW
COP
1.77
2.27
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
149 %
Prated
6.17 kW
4.95 kW
SCOP
5.46
3.81
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.17 kW
4.94 kW
COP Tj = +2°C
3.53
2.07
Cdh Tj = +2 °C
0.990
0.993
Pdh Tj = +7°C
3.96 kW
3.16 kW
COP Tj = +7°C
5.11
3.36
Cdh Tj = +7 °C
0.978
0.982
Pdh Tj = 12°C
3.99 kW
3.73 kW
COP Tj = 12°C
6.59
4.99
Cdh Tj = +12 °C
0.972
0.977
Pdh Tj = Tbiv
6.17 kW
4.94 kW
COP Tj = Tbiv
3.53
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.17 kW
4.94 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1510 kWh
1737 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
145 %
106 %
Prated
6.74 kW
5.44 kW
SCOP
3.69
2.72
Tbiv
-15 °C
-15 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
4.08 kW
3.27 kW
COP Tj = -7°C
3.44
2.28
Cdh Tj = -7 °C
0.986
0.988
Pdh Tj = +2°C
3.08 kW
2.81 kW
COP Tj = +2°C
4.79
3.40
Cdh Tj = +2 °C
0.974
0.979
Pdh Tj = +7°C
3.51 kW
3.29 kW
COP Tj = +7°C
5.72
4.35
Cdh Tj = +7 °C
0.972
0.978
Pdh Tj = 12°C
4.01 kW
3.83 kW
COP Tj = 12°C
6.62
5.61
Cdh Tj = +12 °C
0.972
0.975
Pdh Tj = Tbiv
5.50 kW
4.44 kW
COP Tj = Tbiv
2.81
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.50 kW
4.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
1.99
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.991
0.992
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.74 kW
5.44 kW
Annual energy consumption Qhe
4500 kWh
4933 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.50
4.43
COP Tj = -15°C (if TOL<-20°C)
2.81
1.99
Cdh Tj = -15 °C
0.991
0.992
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
122 %
Prated
5.84 kW
4.78 kW
SCOP
4.46
3.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.19 kW
4.20 kW
COP Tj = -7°C
3.04
1.91
Cdh Tj = -7 °C
0.990
0.992
Pdh Tj = +2°C
3.01 kW
2.52 kW
COP Tj = +2°C
4.53
3.09
Cdh Tj = +2 °C
0.974
0.979
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.57
4.08
Cdh Tj = +7 °C
0.973
0.978
Pdh Tj = 12°C
3.49 kW
3.81 kW
COP Tj = 12°C
5.57
5.35
Cdh Tj = +12 °C
0.973
0.976
Pdh Tj = Tbiv
5.84 kW
4.77 kW
COP Tj = Tbiv
2.68
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.84 kW
4.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2708 kWh
3163 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
100 %
COP
2.34
Heating up time
01:42 h:min
Standby power input
63.0 W
Reference hot water temperature
50.9 °C
Mixed water at 40°C
247 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
70 %
COP
1.61
Heating up time
01:56 h:min
Standby power input
111.2 W
Reference hot water temperature
50.5 °C
Mixed water at 40°C
244 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
87 %
COP
2.04
Heating up time
02:08 h:min
Standby power input
62.2 W
Reference hot water temperature
51.1 °C
Mixed water at 40°C
238 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
7.62 kW
El input
1.96 kW
3.46 kW
COP
1.77
2.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
148 %
Prated
6.39 kW
5.81 kW
SCOP
5.45
3.77
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.39 kW
5.81 kW
COP Tj = +2°C
3.10
2.02
Cdh Tj = +2 °C
0.992
0.994
Pdh Tj = +7°C
4.22 kW
3.72 kW
COP Tj = +7°C
5.21
3.36
Cdh Tj = +7 °C
0.979
0.985
Pdh Tj = 12°C
4.01 kW
3.72 kW
COP Tj = 12°C
6.57
4.84
Cdh Tj = +12 °C
0.972
0.978
Pdh Tj = Tbiv
6.39 kW
5.81 kW
COP Tj = Tbiv
3.10
2.02
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.39 kW
5.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.10
2.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1566 kWh
2058 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
141 %
109 %
Prated
7.30 kW
6.80 kW
SCOP
3.59
2.80
Tbiv
-15 °C
-15 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
4.40 kW
4.12 kW
COP Tj = -7°C
3.29
2.37
Cdh Tj = -7 °C
0.987
0.990
Pdh Tj = +2°C
3.00 kW
2.73 kW
COP Tj = +2°C
4.74
3.55
Cdh Tj = +2 °C
0.973
0.978
Pdh Tj = +7°C
3.47 kW
3.26 kW
COP Tj = +7°C
5.56
4.38
Cdh Tj = +7 °C
0.973
0.977
Pdh Tj = 12°C
4.03 kW
3.87 kW
COP Tj = 12°C
6.74
5.47
Cdh Tj = +12 °C
0.972
0.976
Pdh Tj = Tbiv
6.00 kW
5.55 kW
COP Tj = Tbiv
2.43
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.00 kW
5.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.43
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7.30 kW
6.80 kW
Annual energy consumption Qhe
5007 kWh
5992 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.00
5.55
COP Tj = -15°C (if TOL<-20°C)
2.43
1.86
Cdh Tj = -15 °C
0.993
0.994
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
121 %
Prated
6.80 kW
5.31 kW
SCOP
4.24
3.10
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.92 kW
4.78 kW
COP Tj = -7°C
2.64
1.90
Cdh Tj = -7 °C
0.992
0.993
Pdh Tj = +2°C
3.58 kW
2.80 kW
COP Tj = +2°C
4.22
3.11
Cdh Tj = +2 °C
0.980
0.981
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.51
3.96
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
3.91 kW
3.81 kW
COP Tj = 12°C
6.40
5.22
Cdh Tj = +12 °C
0.972
0.977
Pdh Tj = Tbiv
6.80 kW
5.31 kW
COP Tj = Tbiv
2.54
1.54
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.80 kW
5.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3311 kWh
3535 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
7.62 kW
El input
1.96 kW
3.46 kW
COP
1.77
2.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
148 %
Prated
6.39 kW
5.81 kW
SCOP
5.45
3.77
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.39 kW
5.81 kW
COP Tj = +2°C
3.10
2.02
Cdh Tj = +2 °C
0.992
0.994
Pdh Tj = +7°C
4.22 kW
3.72 kW
COP Tj = +7°C
5.21
3.36
Cdh Tj = +7 °C
0.979
0.985
Pdh Tj = 12°C
4.01 kW
3.72 kW
COP Tj = 12°C
6.57
4.84
Cdh Tj = +12 °C
0.972
0.978
Pdh Tj = Tbiv
6.39 kW
5.81 kW
COP Tj = Tbiv
3.10
2.02
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.39 kW
5.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.10
2.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1566 kWh
2058 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
141 %
109 %
Prated
7.30 kW
6.80 kW
SCOP
3.59
2.80
Tbiv
-15 °C
-15 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
4.40 kW
4.12 kW
COP Tj = -7°C
3.29
2.37
Cdh Tj = -7 °C
0.987
0.990
Pdh Tj = +2°C
3.00 kW
2.73 kW
COP Tj = +2°C
4.74
3.55
Cdh Tj = +2 °C
0.973
0.978
Pdh Tj = +7°C
3.47 kW
3.26 kW
COP Tj = +7°C
5.56
4.38
Cdh Tj = +7 °C
0.973
0.977
Pdh Tj = 12°C
4.03 kW
3.87 kW
COP Tj = 12°C
6.74
5.47
Cdh Tj = +12 °C
0.972
0.976
Pdh Tj = Tbiv
6.00 kW
5.55 kW
COP Tj = Tbiv
2.43
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.00 kW
5.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.43
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5007 kWh
5992 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.00
5.55
COP Tj = -15°C (if TOL<-20°C)
2.43
1.86
Cdh Tj = -15 °C
0.993
0.994
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
121 %
Prated
6.80 kW
5.31 kW
SCOP
4.24
3.10
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.92 kW
4.78 kW
COP Tj = -7°C
2.64
1.90
Cdh Tj = -7 °C
0.992
0.993
Pdh Tj = +2°C
3.58 kW
2.80 kW
COP Tj = +2°C
4.22
3.11
Cdh Tj = +2 °C
0.980
0.981
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.51
3.96
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
3.91 kW
3.81 kW
COP Tj = 12°C
6.40
5.22
Cdh Tj = +12 °C
0.972
0.977
Pdh Tj = Tbiv
6.80 kW
5.31 kW
COP Tj = Tbiv
2.54
1.54
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.80 kW
5.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3311 kWh
3535 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
7.62 kW
El input
1.96 kW
3.46 kW
COP
1.77
2.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
148 %
Prated
6.39 kW
5.81 kW
SCOP
5.45
3.77
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.39 kW
5.81 kW
COP Tj = +2°C
3.10
2.02
Cdh Tj = +2 °C
0.992
0.994
Pdh Tj = +7°C
4.22 kW
3.72 kW
COP Tj = +7°C
5.21
3.36
Cdh Tj = +7 °C
0.979
0.985
Pdh Tj = 12°C
4.01 kW
3.72 kW
COP Tj = 12°C
6.57
4.84
Cdh Tj = +12 °C
0.972
0.978
Pdh Tj = Tbiv
6.39 kW
5.81 kW
COP Tj = Tbiv
3.10
2.02
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.39 kW
5.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.10
2.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1566 kWh
2058 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
141 %
109 %
Prated
7.30 kW
6.80 kW
SCOP
3.59
2.80
Tbiv
-15 °C
-15 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
4.40 kW
4.12 kW
COP Tj = -7°C
3.29
2.37
Cdh Tj = -7 °C
0.987
0.990
Pdh Tj = +2°C
3.00 kW
2.73 kW
COP Tj = +2°C
4.74
3.55
Cdh Tj = +2 °C
0.973
0.978
Pdh Tj = +7°C
3.47 kW
3.26 kW
COP Tj = +7°C
5.56
4.38
Cdh Tj = +7 °C
0.973
0.977
Pdh Tj = 12°C
4.03 kW
3.87 kW
COP Tj = 12°C
6.74
5.47
Cdh Tj = +12 °C
0.972
0.976
Pdh Tj = Tbiv
6.00 kW
5.55 kW
COP Tj = Tbiv
2.43
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.00 kW
5.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.43
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7.30 kW
6.80 kW
Annual energy consumption Qhe
5007 kWh
5992 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.00
1.86
COP Tj = -15°C (if TOL<-20°C)
2.43
1.86
Cdh Tj = -15 °C
0.993
0.994
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
121 %
Prated
6.80 kW
5.31 kW
SCOP
4.24
3.10
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.92 kW
4.78 kW
COP Tj = -7°C
2.64
1.90
Cdh Tj = -7 °C
0.992
0.993
Pdh Tj = +2°C
3.58 kW
2.80 kW
COP Tj = +2°C
4.22
3.11
Cdh Tj = +2 °C
0.980
0.981
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.51
3.96
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
3.91 kW
3.81 kW
COP Tj = 12°C
6.40
5.22
Cdh Tj = +12 °C
0.972
0.977
Pdh Tj = Tbiv
6.80 kW
5.31 kW
COP Tj = Tbiv
2.54
1.54
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.80 kW
5.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3311 kWh
3535 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
113 %
COP
2.65
Heating up time
01:44 h:min
Standby power input
51.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
252 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
72 %
COP
1.64
Heating up time
02:43 h:min
Standby power input
109.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
250 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
94 %
COP
2.22
Heating up time
02:11 h:min
Standby power input
58.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
254 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
7.62 kW
El input
1.96 kW
3.46 kW
COP
1.77
2.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
148 %
Prated
6.39 kW
5.81 kW
SCOP
5.45
3.77
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.39 kW
5.81 kW
COP Tj = +2°C
3.10
2.02
Cdh Tj = +2 °C
0.992
0.994
Pdh Tj = +7°C
4.22 kW
3.72 kW
COP Tj = +7°C
5.21
3.36
Cdh Tj = +7 °C
0.979
0.985
Pdh Tj = 12°C
4.01 kW
3.72 kW
COP Tj = 12°C
6.57
4.84
Cdh Tj = +12 °C
0.972
0.978
Pdh Tj = Tbiv
6.39 kW
5.81 kW
COP Tj = Tbiv
3.10
2.02
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.39 kW
5.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.10
2.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1566 kWh
2058 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
141 %
109 %
Prated
7.30 kW
6.80 kW
SCOP
3.59
2.80
Tbiv
-15 °C
-15 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
4.40 kW
4.12 kW
COP Tj = -7°C
3.29
2.37
Cdh Tj = -7 °C
0.987
0.990
Pdh Tj = +2°C
3.00 kW
2.73 kW
COP Tj = +2°C
4.74
3.55
Cdh Tj = +2 °C
0.973
0.978
Pdh Tj = +7°C
3.47 kW
3.26 kW
COP Tj = +7°C
5.56
4.38
Cdh Tj = +7 °C
0.973
0.977
Pdh Tj = 12°C
4.03 kW
3.87 kW
COP Tj = 12°C
6.74
5.47
Cdh Tj = +12 °C
0.972
0.976
Pdh Tj = Tbiv
6.00 kW
5.55 kW
COP Tj = Tbiv
2.43
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.00 kW
5.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.43
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7.30 kW
6.80 kW
Annual energy consumption Qhe
5007 kWh
5992 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.00
5.55
COP Tj = -15°C (if TOL<-20°C)
2.43
1.86
Cdh Tj = -15 °C
0.993
0.994
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
121 %
Prated
6.80 kW
5.31 kW
SCOP
4.24
3.10
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.92 kW
4.78 kW
COP Tj = -7°C
2.64
1.90
Cdh Tj = -7 °C
0.992
0.993
Pdh Tj = +2°C
3.58 kW
2.80 kW
COP Tj = +2°C
4.22
3.11
Cdh Tj = +2 °C
0.980
0.981
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.51
3.96
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
3.91 kW
3.81 kW
COP Tj = 12°C
6.40
5.22
Cdh Tj = +12 °C
0.972
0.977
Pdh Tj = Tbiv
6.80 kW
5.31 kW
COP Tj = Tbiv
2.54
1.54
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.80 kW
5.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3311 kWh
3535 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
100 %
COP
2.34
Heating up time
01:42 h:min
Standby power input
63.0 W
Reference hot water temperature
50.9 °C
Mixed water at 40°C
247 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
70 %
COP
1.61
Heating up time
01:56 h:min
Standby power input
111.2 W
Reference hot water temperature
50.5 °C
Mixed water at 40°C
244 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
87 %
COP
2.04
Heating up time
02:08 h:min
Standby power input
62.2 W
Reference hot water temperature
51.1 °C
Mixed water at 40°C
238 l