2,800 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
11.00 kW
11.00 kW
El input
2.20 kW
3.67 kW
COP
5.00
3.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
135 %
Prated
11.00 kW
10.00 kW
SCOP
4.73
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.60 kW
8.60 kW
COP Tj = -7°C
2.74
1.80
Pdh Tj = +2°C
5.84 kW
5.23 kW
COP Tj = +2°C
5.20
3.60
Pdh Tj = +7°C
3.76 kW
3.52 kW
COP Tj = +7°C
5.80
4.80
Pdh Tj = 12°C
3.70 kW
3.60 kW
COP Tj = 12°C
6.40
5.80
Pdh Tj = Tbiv
9.60 kW
8.60 kW
COP Tj = Tbiv
2.74
1.80
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.50 kW
8.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.65
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
55 °C
55 °C
Poff
19 W
19 W
PTO
0 W
0 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.50 kW
1.20 kW
Annual energy consumption Qhe
4736 kWh
5808 kWh
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
11.00 kW
11.00 kW
El input
2.20 kW
3.67 kW
COP
5.00
3.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
137 %
Prated
11.00 kW
10.00 kW
SCOP
4.80
3.50
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.60 kW
8.60 kW
COP Tj = -7°C
2.74
1.80
Pdh Tj = +2°C
5.84 kW
5.23 kW
COP Tj = +2°C
5.20
3.60
Pdh Tj = +7°C
3.76 kW
3.52 kW
COP Tj = +7°C
5.80
4.80
Pdh Tj = 12°C
3.70 kW
3.60 kW
COP Tj = 12°C
6.40
5.80
Pdh Tj = Tbiv
9.60 kW
8.60 kW
COP Tj = Tbiv
2.74
1.80
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.50 kW
8.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.65
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
55 °C
55 °C
Poff
19 W
19 W
PTO
0 W
0 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.50 kW
1.20 kW
Annual energy consumption Qhe
4666 kWh
5738 kWh