Certificate holders

Subtype

AUD + G140

Certificate Holder
Argoclima S.p.A
Via Alfeno Varo, 35
25020 Alfianello (BS)
Italy
Registration number
ICIM-PDC-000025-01 / 01
Certification Body
ICIM S.p.A.
Subtype title
AUD + G140
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

4,400 kg

Certification Date
21.02.2019
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

AUDH + AEI1G140EMX3PH
Configure model
Model name
AUDH + AEI1G140EMX3PH
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

13.63 kW

10.42 kW

El input

3.50 kW

4.84 kW

COP

3.90

2.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

111 %

Prated

11.86 kW

9.36 kW

SCOP

4.09

2.84

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.49 kW

8.28 kW

COP Tj = -7°C

2.53

1.53

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.27 kW

5.19 kW

COP Tj = +2°C

4.08

2.91

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.34 kW

5.05 kW

COP Tj = +7°C

5.65

4.11

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.76 kW

4.57 kW

COP Tj = 12°C

6.28

5.31

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.49 kW

8.28 kW

COP Tj = Tbiv

2.53

1.53

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.79 kW

5.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.32

1.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

5 W

5 W

PTO

8 W

8 W

PSB

5 W

5 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.07 kW

3.54 kW

Annual energy consumption Qhe

5987 kWh

6811 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

80 %

COP

1.99

Heating up time

2:07 h:min

Standby power input

52.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

364 l

AUDH + AEI1G140EMX
Configure model
Model name
AUDH + AEI1G140EMX
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

13.63 kW

10.42 kW

El input

3.50 kW

4.84 kW

COP

3.90

2.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

111 %

Prated

11.86 kW

9.36 kW

SCOP

4.09

2.84

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.49 kW

8.28 kW

COP Tj = -7°C

2.53

1.53

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.27 kW

5.19 kW

COP Tj = +2°C

4.08

2.91

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.34 kW

5.05 kW

COP Tj = +7°C

5.65

4.11

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.76 kW

4.57 kW

COP Tj = 12°C

6.28

5.31

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.49 kW

8.28 kW

COP Tj = Tbiv

2.53

1.53

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.79 kW

5.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.32

1.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

5 W

5 W

PTO

8 W

8 W

PSB

5 W

5 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.07 kW

3.54 kW

Annual energy consumption Qhe

5987 kWh

6811 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

80 %

COP

1.99

Heating up time

2:07 h:min

Standby power input

52.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

364 l