Certificate holders

Subtype

AUA + G50

Certificate Holder
Argoclima S.p.A
Via Alfeno Varo, 35
25020 Alfianello (BS)
Italy
Registration number
ICIM-PDC-000021-01 / 01
Certification Body
ICIM S.p.A.
Subtype title
AUA + G50
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,300 kg

Certification Date
21.02.2019
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

AUAH + AEI1G50EMX
Configure model
Model name
AUAH + AEI1G50EMX
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.95 kW

4.10 kW

El input

0.97 kW

1.72 kW

COP

4.09

2.39

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

151 %

111 %

Prated

2.86 kW

3.41 kW

SCOP

3.85

2.84

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

2.53 kW

3.01 kW

COP Tj = -7°C

2.26

1.75

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

1.51 kW

1.86 kW

COP Tj = +2°C

3.78

2.78

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.02 kW

1.13 kW

COP Tj = +7°C

5.30

3.74

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

0.93 kW

1.31 kW

COP Tj = 12°C

7.02

5.88

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

2.53 kW

3.01 kW

COP Tj = Tbiv

2.26

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.32 kW

2.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.02

1.11

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

5 W

5 W

PTO

8 W

8 W

PSB

5 W

5 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.53 kW

1.34 kW

Annual energy consumption Qhe

1534 kWh

2479 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

90 %

COP

2.22

Heating up time

5:36 h:min

Standby power input

45.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

364 l