1,460 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.08 kW
5.87 kW
El input
1.93 kW
2.71 kW
COP
4.19
2.17
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
69 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
159 %
113 %
Prated
6.51 kW
5.50 kW
SCOP
4.05
2.91
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.76 kW
4.87 kW
COP Tj = -7°C
2.83
1.83
Pdh Tj = +2°C
3.54 kW
3.02 kW
COP Tj = +2°C
3.82
2.85
Pdh Tj = +7°C
2.27 kW
1.85 kW
COP Tj = +7°C
5.29
3.67
Pdh Tj = 12°C
1.52 kW
1.48 kW
COP Tj = 12°C
6.45
5.63
Pdh Tj = Tbiv
5.76 kW
4.87 kW
COP Tj = Tbiv
2.83
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.42 kW
3.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
1.46
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
55 °C
55 °C
Poff
5 W
5 W
PTO
8 W
8 W
PSB
5 W
5 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.09 kW
1.53 kW
Annual energy consumption Qhe
3326 kWh
3904 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
94 %
COP
2.25
Heating up time
3:41 h:min
Standby power input
53.2 W
Reference hot water temperature
46.7 °C
Mixed water at 40°C
364 l