5,100 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
28.00 kW
27.30 kW
El input
6.35 kW
9.99 kW
COP
4.41
2.73
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
7.99 kW
Cooling capacity
24.20
EER
3.03
EN 14825
+7°C/+12°C
Pdesignc
24.20 kW
SEER
4.76
Pdc Tj = 35°C
24.20 kW
EER Tj = 35°C
3.03
Pdc Tj = 30°C
17.74 kW
EER Tj = 30°C
4.12
Cdc Tj = 30 °C
1.000
Pdc Tj = 25°C
11.32 kW
EER Tj = 25°C
5.38
Cdc Tj = 25 °C
0.900
Pdc Tj = 20°C
12.26 kW
EER Tj = 20°C
6.47
Cdc Tj = 20 °C
0.900
Poff
22 W
PTO
0 W
PSB
28 W
PCK
0 W
Annual energy consumption Qce
3037 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
126 %
Prated
25.00 kW
24.00 kW
SCOP
4.29
3.23
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-10 °C
Pdh Tj = -7°C
21.70 kW
20.80 kW
COP Tj = -7°C
2.68
1.93
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
13.20 kW
12.80 kW
COP Tj = +2°C
4.26
3.20
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
11.90 kW
11.50 kW
COP Tj = +7°C
5.39
4.10
Cdh Tj = +7 °C
0.993
0.995
Pdh Tj = 12°C
13.70 kW
13.50 kW
COP Tj = 12°C
7.06
5.77
Cdh Tj = +12 °C
0.992
0.993
Pdh Tj = Tbiv
21.70 kW
20.80 kW
COP Tj = Tbiv
2.68
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
19.30 kW
18.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.41
1.73
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
5.70 kW
5.20 kW
Annual energy consumption Qhe
11823 kWh
15056 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
32.10 kW
31.80 kW
El input
7.84 kW
12.10 kW
COP
4.09
2.64
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
8.65 kW
Cooling capacity
26.00
EER
3.01
EN 14825
+7°C/+12°C
Pdesignc
26.00 kW
SEER
4.81
Pdc Tj = 35°C
26.00 kW
EER Tj = 35°C
3.01
Pdc Tj = 30°C
19.10 kW
EER Tj = 30°C
4.15
Cdc Tj = 30 °C
1.000
Pdc Tj = 25°C
12.27 kW
EER Tj = 25°C
5.35
Cdc Tj = 25 °C
1.000
Pdc Tj = 20°C
12.56 kW
EER Tj = 20°C
6.63
Cdc Tj = 20 °C
0.900
Poff
22 W
PTO
0 W
PSB
28 W
PCK
0 W
Annual energy consumption Qce
3241 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
122 %
Prated
24.00 kW
25.00 kW
SCOP
4.02
3.14
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-10 °C
Pdh Tj = -7°C
21.30 kW
21.70 kW
COP Tj = -7°C
2.57
1.90
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
13.00 kW
13.30 kW
COP Tj = +2°C
3.94
3.09
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
11.60 kW
11.90 kW
COP Tj = +7°C
5.03
3.96
Cdh Tj = +7 °C
0.993
0.995
Pdh Tj = 12°C
13.50 kW
14.00 kW
COP Tj = 12°C
6.96
5.51
Cdh Tj = +12 °C
0.992
0.994
Pdh Tj = Tbiv
21.30 kW
21.70 kW
COP Tj = Tbiv
2.57
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
18.80 kW
19.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.29
1.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
5.20 kW
5.50 kW
Annual energy consumption Qhe
12369 kWh
16150 kWh