7,900 kg
Heating
EN 14511-2
Heat output
25.30 kW
El input
6.07 kW
COP
4.17
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Average Climate
EN 12102-1
Sound power level outdoor
75 dB(A)
EN 14825
ηs
169 %
Prated
21.00 kW
SCOP
4.30
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
18.30 kW
COP Tj = -7°C
2.95
Cdh Tj = -7 °C
0.90
Pdh Tj = +2°C
11.20 kW
COP Tj = +2°C
4.10
Cdh Tj = +2 °C
0.90
Pdh Tj = +7°C
7.20 kW
COP Tj = +7°C
5.60
Cdh Tj = +7 °C
0.90
Pdh Tj = 12°C
7.10 kW
COP Tj = 12°C
6.82
Cdh Tj = +12 °C
0.90
Pdh Tj = Tbiv
20.70 kW
COP Tj = Tbiv
2.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
20.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
WTOL
54 °C
Poff
19 W
PTO
200 W
PSB
19 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
9946 kWh
Heating
EN 14511-2
Heat output
28.20 kW
El input
6.64 kW
COP
4.25
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Average Climate
EN 12102-1
Sound power level outdoor
76 dB(A)
EN 14825
ηs
167 %
Prated
22.00 kW
SCOP
4.25
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
19.10 kW
COP Tj = -7°C
2.92
Cdh Tj = -7 °C
0.90
Pdh Tj = +2°C
11.60 kW
COP Tj = +2°C
4.00
Cdh Tj = +2 °C
0.90
Pdh Tj = +7°C
7.50 kW
COP Tj = +7°C
5.65
Cdh Tj = +7 °C
0.90
Pdh Tj = 12°C
7.10 kW
COP Tj = 12°C
6.82
Cdh Tj = +12 °C
0.90
Pdh Tj = Tbiv
21.60 kW
COP Tj = Tbiv
2.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
21.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
WTOL
54 °C
Poff
19 W
PTO
200 W
PSB
19 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
10500 kWh
Heating
EN 14511-2
Heat output
32.00 kW
El input
7.69 kW
COP
4.16
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Average Climate
EN 12102-1
Sound power level outdoor
76 dB(A)
EN 14825
ηs
167 %
Prated
24.00 kW
SCOP
4.24
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
20.90 kW
COP Tj = -7°C
2.86
Cdh Tj = -7 °C
0.90
Pdh Tj = +2°C
12.70 kW
COP Tj = +2°C
3.98
Cdh Tj = +2 °C
0.90
Pdh Tj = +7°C
8.20 kW
COP Tj = +7°C
5.75
Cdh Tj = +7 °C
0.90
Pdh Tj = 12°C
7.10 kW
COP Tj = 12°C
6.82
Cdh Tj = +12 °C
0.90
Pdh Tj = Tbiv
23.60 kW
COP Tj = Tbiv
2.57
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
23.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
WTOL
54 °C
Poff
19 W
PTO
200 W
PSB
19 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
11514 kWh